Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles
被引:13
作者:
Antonini, Filippo
论文数: 0引用数: 0
h-index: 0
机构:
Polytech Univ Marche, Augusto Murri Hosp, Div Gastroenterol, Fermo, ItalyPolytech Univ Marche, Augusto Murri Hosp, Div Gastroenterol, Fermo, Italy
Antonini, Filippo
[1
]
Fuccio, Lorenzo
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bologna, S Orsola Malpighi Hosp, Dept Med & Surg Sci, Div Gastroenterol, Bologna, ItalyPolytech Univ Marche, Augusto Murri Hosp, Div Gastroenterol, Fermo, Italy
Objective: While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. Methods: All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. Results: A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p = 0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48 h or >= 48 h before EUS). No EUS-FNB related complications were recorded. Conclusion: The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. (C) 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
机构:
MacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
Mackay Med Nursing & Management Coll, Dept Nursing, Taipei 11260, Taiwan
MacKay Med Coll, Dept Med, New Taipei 25245, TaiwanMacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
Lai, Jian-Han
Lin, Ching-Chung
论文数: 0引用数: 0
h-index: 0
机构:
MacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
MacKay Med Coll, Dept Med, New Taipei 25245, TaiwanMacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
Lin, Ching-Chung
Ho, Kung-Chen
论文数: 0引用数: 0
h-index: 0
机构:
Mackay Mem Hosp, Dept Surg, Div Gen Surg, Taipei 104217, Taiwan
MacKay Med Coll, Dept Med, New Taipei 25245, TaiwanMacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
Ho, Kung-Chen
Chang, Chen-Wang
论文数: 0引用数: 0
h-index: 0
机构:
MacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
Mackay Med Nursing & Management Coll, Dept Nursing, Taipei 11260, Taiwan
MacKay Med Coll, Dept Med, New Taipei 25245, TaiwanMacKay Mem Hosp, Dept Internal Med, Div Gastroenterol, Taipei 10449, Taiwan
机构:
Div Gastroenterol, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Levine, Irving
Suchman, Kelly
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Suchman, Kelly
Patel, Zankesh
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Patel, Zankesh
Ghani, Maham
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Ghani, Maham
Hussein, Karim
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Hussein, Karim
Ramada, Michael
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Ramada, Michael
Cubillan, Mark Patrick
论文数: 0引用数: 0
h-index: 0
机构:
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Dept Med, Northwell Hlth Syst, New Hyde Pk, NY USADiv Gastroenterol, New Hyde Pk, NY USA
Cubillan, Mark Patrick
Garg, Shashank
论文数: 0引用数: 0
h-index: 0
机构:
Univ Arkansas Med Sci, Dept Med, Div Gastroenteorl, Little Rock, AR USADiv Gastroenterol, New Hyde Pk, NY USA
Garg, Shashank
Trindade, Arvind J.
论文数: 0引用数: 0
h-index: 0
机构:
Div Gastroenterol, New Hyde Pk, NY USA
Long Isl Jewish Med Ctr, Zucker Sch Med Hofstra Northwell, Div Gastroenterol, Northwell Hlth Syst, 270-05 76th Ave, New Hyde Pk, NY 11040 USADiv Gastroenterol, New Hyde Pk, NY USA