Biliary plastic stent does not influence the accuracy of endoscopic ultrasound-guided sampling of pancreatic head masses performed with core biopsy needles

被引:14
作者
Antonini, Filippo [1 ]
Fuccio, Lorenzo [2 ]
Giorgini, Sara [3 ]
Fabbri, Carlo [4 ]
Frazzoni, Leonardo [2 ]
Scarpelli, Marina [3 ]
Macarri, Giampiero [1 ]
机构
[1] Polytech Univ Marche, Augusto Murri Hosp, Div Gastroenterol, Fermo, Italy
[2] Univ Bologna, S Orsola Malpighi Hosp, Dept Med & Surg Sci, Div Gastroenterol, Bologna, Italy
[3] Polytech Univ Marche, Dept Biomed Sci & Publ Hlth, Pathol Anat & Histopathol, Ancona, Italy
[4] Bellaria Maggiore Hosp, AUSL Bologna, Unit Gastroenterol & Digest Endoscopy, Bologna, Italy
关键词
Accuracy; Biliary stent; Biopsy; Endoscopic ultrasound; EUS-FNA; Fine needle aspiration; Pancreatic cancer; DIAGNOSTIC-ACCURACY; ASPIRATION; FEASIBILITY; YIELD; MULTICENTER; LESIONS; IMPACT;
D O I
10.1016/j.dld.2017.04.007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Objective: While the presence of biliary stent significantly decreases the accuracy of endoscopic ultrasound (EUS) for pancreatic head cancer staging, its impact on the EUS-guided sampling accuracy is still debated. Furthermore, data on EUS-fine needle biopsy (EUS-FNB) using core biopsy needles in patients with pancreatic mass and biliary stent are lacking. The aim of this study was to evaluate the influence of biliary stent on the adequacy and accuracy of EUS-FNB in patients with pancreatic head mass. Methods: All patients who underwent EUS-guided sampling with core needles of solid pancreatic head masses causing obstructive jaundice were retrospectively identified in a single tertiary referral center. Adequacy, defined as the rate of cases in which a tissue specimen for proper examination was achieved, with and without biliary stent, was the primary outcome measure. The diagnostic accuracy and complication rate were the secondary outcome measures. Results: A total of 130 patients with pancreatic head mass causing biliary obstruction were included in the study: 74 cases of them were sampled without stent and 56 cases with plastic stent in situ. The adequacy was 96.4% in the stent group and 90.5% in the group without stent (p = 0.190). No significant differences were observed for sensitivity (88.9% vs. 85.9%), specificity (100% for both groups), and accuracy (89.3% vs. 86.5%) between those with and without stent, respectively. The accuracy was not influenced by the timing of stenting (<48 h or >= 48 h before EUS). No EUS-FNB related complications were recorded. Conclusion: The presence of biliary stent does not influence the tissue sampling adequacy, the diagnostic accuracy and the complication rate of EUS-FNB of pancreatic head masses performed with core biopsy needles. (C) 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:898 / 902
页数:5
相关论文
共 29 条
[11]   Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration [J].
Fabbri, Carlo ;
Luigiano, Carmelo ;
Maimone, Antonella ;
Tarantino, Ilaria ;
Baccarini, Paola ;
Fornelli, Adele ;
Liotta, Rosa ;
Polifemo, Annamaria ;
Barresi, Luca ;
Traina, Mario ;
Virgilio, Clara ;
Cennamo, Vincenzo .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2015, 29 (06) :1586-1590
[12]   The Impact of Prior Biliary Stenting on the Accuracy and Complication Rate of Endoscopic Ultrasound Fine-Needle Aspiration for Diagnosing Pancreatic Adenocarcinoma [J].
Fisher, Jessica M. ;
Gordon, Stuart R. ;
Gardner, Timothy B. .
PANCREAS, 2011, 40 (01) :21-24
[13]   Endoscopic ultrasound-guided fine needle aspiration: How to obtain a core biopsy? [J].
Fuccio, Lorenzo ;
Larghil, Alberto .
ENDOSCOPIC ULTRASOUND, 2014, 3 (02) :71-81
[14]  
Fusaroli P, INFLUENCE ENDOSCOPIC
[15]  
Giovannini M, 1995, ENDOSCOPY
[16]   Number Needed to Misdiagnose A Measure of Diagnostic Test Effectiveness [J].
Habibzadeh, Farrokh ;
Yadollahie, Mahboobeh .
EPIDEMIOLOGY, 2013, 24 (01) :170-170
[17]   Feasibility and efficiency of a new 22G core needle: a prospective comparison study [J].
Hucl, Tomas ;
Wee, Eric ;
Anuradha, Sekaran ;
Gupta, Rajesh ;
Ramchandani, Mohan ;
Rakesh, Kalpala ;
Shrestha, Ramila ;
Reddy, Duvvuru Nageshwar ;
Lakhtakia, Sundeep .
ENDOSCOPY, 2013, 45 (10) :792-798
[18]   Feasibility and yield of a new EUS histology needle: results from a multicenter, pooled, cohort study [J].
Iglesias-Garcia, Julio ;
Poley, Jan-Werner ;
Larghi, Alberto ;
Giovannini, Marc ;
Chiara Petrone, Maria ;
Abdulkader, Ihab ;
Monges, Genevieve ;
Costamagna, Guido ;
Arcidiacono, Paolo ;
Biermann, Katharina ;
Rindi, Guido ;
Bories, Erwan ;
Dogloni, Claudio ;
Bruno, Marco ;
Enrique Dominguez-Munoz, J. .
GASTROINTESTINAL ENDOSCOPY, 2011, 73 (06) :1189-1196
[19]   Lower Yield of Endoscopic Ultrasound-Guided Fine-Needle Aspiration in Patients with Pancreatic Head Mass with a Biliary Stent [J].
Kim, John J. ;
Walia, Sukhpreet ;
Lee, Scott H. ;
Patel, Bhavesh ;
Vetsa, Madhavi ;
Zhao, Yan ;
Srikureja, Wichit ;
Laine, Loren .
DIGESTIVE DISEASES AND SCIENCES, 2015, 60 (02) :543-549
[20]   Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study [J].
Larghi, Alberto ;
Iglesias-Garcia, Julio ;
Poley, Jan-Werner ;
Monges, Genevieve ;
Petrone, Maria Chiara ;
Rindi, Guido ;
Abdulkader, Ihab ;
Arcidiacono, Paolo Giorgio ;
Costamagna, Guido ;
Biermann, Katharina ;
Bories, Erwan ;
Doglioni, Claudio ;
Enrique Dominguez-Munoz, J. ;
Hassan, Cesare ;
Bruno, Marco ;
Giovannini, Marc .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2013, 27 (10) :3733-3738