Novel control scheme based on per-phase reference current calculation for hybrid series active power filter with fundamental current bypass channel in unbalanced conditions

被引:3
|
作者
Zhong, HH [1 ]
Chen, PP [1 ]
Lu, ZG [1 ]
Qian, ZM [1 ]
机构
[1] Zhejiang Univ, Natl Key Lab Power Elect, Hangzhou 310027, Peoples R China
关键词
D O I
10.1109/PESC.2004.1355557
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Novel Control Scheme based on per-phase reference current calculation for Hybrid Series Active Power Filter is proposed. By this control scheme, the Voltage Source Inverter (VSI) delivers the harmonic power only, both in balanced and unbalanced conditions. So the required rating of the active filter can be much smaller than that of conventional one. A 2.4 KW prototype is implemented digitally by TMS320F2407A(DSP). The experimental results show that it is suitable for high power harmonic suppression.
引用
收藏
页码:999 / 1002
页数:4
相关论文
共 50 条
  • [41] A novel active damping control based on grid-side current feedback for LCL-filter active power filter
    Gao, Tingting
    Lin, Yanqiang
    Chen, Dongdong
    Xiao, Long
    ENERGY REPORTS, 2020, 6 (06) : 1318 - 1324
  • [42] An optimal current control scheme in grid-tied hybrid energy system with active power filter for harmonic mitigation
    Babu, Narendra P.
    Babu, Chitti B.
    Peesapati, Ranga Babu
    Panda, Gayadhar
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2020, 30 (03)
  • [43] Research on the filtering characteristic of single phase series hybrid active power filter based on fundamental magnetic flux compensation
    Tian, Jun
    Chen, Qiaofu
    Zhang, Yuqi
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2012, 99 (12) : 1703 - 1715
  • [44] Novel Current-Tracking Control for Hybrid Active Power Filter with Injection Circuit and Its Engineering Application
    Xu, Xian-yong
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER AND RENEWABLE ENERGY (ICPRE), 2016, : 269 - 274
  • [45] A NOVEL REFERENCE CURRENT GENERATION METHOD OF PV BASED THREE LEVEL NPC SHUNT ACTIVE POWER FILTER
    Vijayakumar, M.
    Ramasamy, M.
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2015, 77 (03): : 235 - 250
  • [46] Novel control scheme for 3-phase PWM current-source converters under unbalanced source voltage conditions
    李玉玲
    楼珍丽
    张仲超
    Journal of Zhejiang University Science A(Science in Engineering), 2006, (02) : 263 - 268
  • [47] A Novel Single-Phase Shunt Active Power Filter with a Cost Function Based Model Predictive Current Control Technique
    Aljafari, Belqasem
    Rameshkumar, Kanagavel
    Indragandhi, Vairavasundaram
    Ramachandran, Selvamathi
    ENERGIES, 2022, 15 (13)
  • [48] Novel control scheme for 3-phase PWM current-source converters under unbalanced source voltage conditions
    Li Y.-L.
    Lou Z.-L.
    Zhang Z.-C.
    Journal of Zhejiang University-SCIENCE A, 2006, 7 (2): : 263 - 268
  • [49] Analysis of Levenberg Marquardt- ANN based reference current generation for control of shunt active power filter
    Deshpande, Vaidehi
    Modi, Pramod
    Sant, Amit V.
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 7104 - 7108
  • [50] A Novel Control Scheme for Dynamic Reactive Power Compensation Multilevel Inverter Based Shunt Hybrid Active Power Filter
    Demirdelen, Tugce
    Tumay, Mehmet
    2016 UKSIM-AMSS 18TH INTERNATIONAL CONFERENCE ON COMPUTER MODELLING AND SIMULATION (UKSIM), 2016, : 217 - 223