Global cardiac function using fast breath-hold MRI: Validation of new acquisition and analysis techniques

被引:65
作者
Bloomgarden, DC
Fayad, ZA
Ferrari, VA
Chin, B
Sutton, MGSJ
Axel, L
机构
[1] UNIV PENN, MED CTR, DEPT RADIOL, PHILADELPHIA, PA 19104 USA
[2] UNIV PENN, MED CTR, DEPT CARDIOL, PHILADELPHIA, PA 19104 USA
[3] UNIV PENN, MED CTR, DEPT NUCL MED, PHILADELPHIA, PA 19104 USA
关键词
magnetic resonance imaging; heart; image processing; computer assisted; ventricular function; LEFT-VENTRICULAR VOLUMES; IN-VIVO VALIDATION; MAGNETIC-RESONANCE; 3-DIMENSIONAL ECHOCARDIOGRAPHY; EJECTION FRACTION; CINE; MASS; STANDARD; HEART; REPRODUCIBILITY;
D O I
10.1002/mrm.1910370510
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Calculation of global cardiac function parameters has been validated using fast, segmented k-space, breath-hold, gradient-echo, magnetic resonance images. Images of phantoms, experimental animals, normal volunteers, and patients were acquired with a 1.5 T clinical scanner, Humans were imaged using two phased-array surface coils in multicoil mode, Myocardial contours were extracted using a new interactive, semi-automated method based on the active contour model method, Images were acquired in the short-axis orientation, and, using a new imaging and analysis strategy, in rotating plane long-axis orientations, to provide better definition of the valve planes and the apex, and also to reduce the number of slices (compared with the short-axis method) required to sample the whole heart, Validation was accomplished through calculation of the volumes of phantoms and left and right ventricular masses of animal hearts. Functional parameters from MRI were compared with those from echocardiograms and radionuclide angiograms in normal volunteers and patients, respectively.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 40 条
  • [1] CINEANGIOGRAPHY OF THE HEART IN A SINGLE BREATH HOLD WITH A SEGMENTED TURBOFLASH SEQUENCE
    ATKINSON, DJ
    EDELMAN, RR
    [J]. RADIOLOGY, 1991, 178 (02) : 357 - 360
  • [2] LEFT-VENTRICULAR MASS QUANTITATION USING SINGLE-PHASE CARDIAC MAGNETIC-RESONANCE-IMAGING
    AURIGEMMA, G
    DAVIDOFF, A
    SILVER, K
    BOEHMER, J
    SERIO, A
    PATTISON, N
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (02) : 259 - 262
  • [3] EFFICIENT METHOD FOR SELECTING CARDIAC MAGNETIC-RESONANCE IMAGE LOCATIONS
    AXEL, L
    [J]. INVESTIGATIVE RADIOLOGY, 1992, 27 (01) : 91 - 93
  • [4] AXEL L, 1992, RADIOLOGY, V185, P223
  • [5] AXEL L, 1995, P COMP CARD 22 ANN M, P625
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] BLOOMGARDEN DC, 1995, P AM COLL CARD 44 AN, pA113
  • [8] LEFT-VENTRICULAR VOLUME MEASUREMENT USING CARDIAC AXIS NUCLEAR-MAGNETIC-RESONANCE IMAGING - VALIDATION BY CALIBRATED VENTRICULAR ANGIOGRAPHY
    CRANNEY, GB
    LOTAN, CS
    DEAN, L
    BAXLEY, W
    BOUCHARD, A
    POHOST, GM
    [J]. CIRCULATION, 1990, 82 (01) : 154 - 163
  • [9] CARDIAC EJECTION FRACTION - PHANTOM STUDY COMPARING CINE MR IMAGING, RADIONUCLIDE BLOOD POOL IMAGING, AND VENTRICULOGRAPHY
    DEBATIN, JF
    NADEL, SN
    PAOLINI, JF
    SOSTMAN, HD
    COLEMAN, RE
    EVANS, AJ
    BEAM, C
    SPRITZER, CE
    BASHORE, TM
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (02): : 135 - 142
  • [10] QUANTIFICATION OF THE LEFT-VENTRICULAR VOLUMES AND FUNCTION WITH CINE MR-IMAGING - COMPARISON OF GEOMETRIC-MODELS WITH 3-DIMENSIONAL DATA
    DULCE, MC
    MOSTBECK, GH
    FRIESE, KK
    CAPUTO, GR
    HIGGINS, CB
    [J]. RADIOLOGY, 1993, 188 (02) : 371 - 376