Novel large-area thermal neutron imaging detectors comprising Gd-157/CsI-convertors and micro-strip gas detectors with low-pressure, two-stage amplification and delay line readout

被引:28
作者
Gebauer, B
Schulz, C
Wilpert, T
机构
[1] Hahn-Meitner-Institut, D-14109 Berlin
关键词
D O I
10.1016/S0168-9002(97)00245-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel large-area (0.5 x 0.5 m(2)) two-dimensional position-sensitive detector for thermal and sub-thermal neutrons is being developed comprising Gd-157/CsI multilayer convertor foils and two fourfold segmented micro-strip gas detector (MSGC) planes for electron multiplication on either side of the convertor. The MSGC operates in low-pressure, two-stage amplification mode; their novel design is optimized for that mode and for obtaining high signals on both coordinates. Fast signal rise times (5-6 ns) and very high gains (similar to 5 x 10(5)) are expected according to calculations; thus, simple delay line readout, with one interpolating strip between readout nodes, can be used delivering expected position resolutions < 0.5 mm (fwhm) and tolerable count rates of 10(5)-10(6) events/s depending on delay line segmentation.
引用
收藏
页码:68 / 72
页数:5
相关论文
共 16 条
[11]   THE ELECTROSTATIC-FIELD IN MICROSTRIP CHAMBERS AND ITS INFLUENCE ON DETECTOR PERFORMANCE [J].
FLORENT, JJ ;
GAUDAEN, J ;
ROPELEWSKI, L ;
SAULI, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 329 (1-2) :125-132
[12]  
GEBAUER B, 1995, NEUARTIGE ORTSABBILD
[13]   CHARACTERISTICS OF SECONDARY-ELECTRON EMISSION FROM CSL INDUCED BY X-RAYS WITH ENERGIES UP TO 100-KEV [J].
GIBREKHTERMAN, A ;
AKKERMAN, A ;
BRESKIN, A ;
CHECHIK, R .
JOURNAL OF APPLIED PHYSICS, 1993, 74 (12) :7506-7509
[14]   USE OF GD IN GAS COUNTERS AS NEUTRON DETECTORS IN SNO [J].
HARGROVE, CK ;
BLEVIS, I ;
PATERSON, D ;
EARLE, ED .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 357 (01) :157-169
[15]   Factors influencing the performances of micro-strip gas chambers [J].
Mack, V ;
Brom, JM ;
Fang, R ;
Fontaine, JC ;
Huss, D ;
Kachelhoffer, T ;
Kettunen, H ;
Levy, JM ;
Pallares, A ;
Barthe, S ;
Bergdolt, AM ;
Cailleret, J ;
Christophel, E ;
Coffin, J ;
Eberle, H ;
Osswald, F ;
Schunck, JP ;
Sigward, MH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 367 (1-3) :173-176
[16]  
SMITH GC, 1992, NUCL INSTRUM METH A, V32, P78