THE EFFECT OF SIGNIFICANT TUMOR REDUCTION ON THE DOSE DISTRIBUTION IN INTENSITY MODULATED RADIATION THERAPY FOR HEAD-AND-NECK CANCER: A CASE STUDY

被引:5
作者
Mechalakos, James [1 ]
Lee, Nancy
Hunt, Margie
Ling, C. Clifton
Amols, Howard I.
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
关键词
IMRT; IGRT; head and neck; planning; CONE-BEAM CT; RADIOTHERAPY; IMRT;
D O I
10.1016/j.meddos.2008.10.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We present a unique case in which a patient with significant tissue loss was monitored for dosimetric changes using weekly cone beam computed tomography (CBCT) scans. A previously treated nasopharynx patient presented with a large, exophytic, recurrent left neck mass. The patient underwent re-irradiation to 70 Gy using intensity modulated radiation therapy (IMRT) with shielding blocks over the spinal cord and brain stem. Weekly CBCT scans were acquired during treatment. Target contours and treatment fields were then transferred from the original treatment planning computed tomography (CT) to the CBCT scans and dose calculations were performed on all CBCT scans and compared to the planning doses. In addition, a "research" treatment plan was created that assumed the patient had not been previously treated, and the above analysis was repeated. Finally, to remove the effects of setup error, the outer contours of 2 CBCT scans with significant tumor reductions were transferred to the planning scan and dose in the planning scan was recalculated. Planning treatment volume (PTV) decreased 45% during treatment. Spinal cord D05 differed from the planned value by 3.5 +/- 9.8% (average + standard deviation). Mean dose to the oral cavity and D05 of the mandible differed from the planned value by 0.9 +/- 2.1% and 0.6 +/- 1.5%, respectively. Results for the research plan were comparable. Target coverage did not change appreciably (-0.2 +/- 2.5%). When the planning scan was recalculated with the reduced outer contour from the CBCT, spinal cord D05 decreased slightly due to the reduction in scattered dose. Weekly imaging provided us the unique opportunity to use different methods to examine the dosimetric effects of an unusually large loss of tissue. We did not see that tissue loss alone resulted in a significant effect on the dose delivered to the spinal cord for this case, as most fluctuation was due to setup error. In the IGRT era, delivered dose distributions can be more readily determined during treatment, and this information can be useful in deciding whether replanning is necessary. (C) 2009 American Association of Medical Dosimetrists.
引用
收藏
页码:250 / 255
页数:6
相关论文
共 18 条
[1]   Is there a trigger point for adaptive replanning during head & neck IMRT? [J].
Ahamad, A. ;
Dong, L. ;
Zhang, L. ;
Ang, K. ;
O'Daniel, J. ;
Theriot, L. ;
Asper, J. ;
Chambers, M. ;
Palla, S. ;
Garden, A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03) :S100-S101
[2]   Megavoltage CT assessment of volume changes in target and non-target tissues of the head and neck over a standard course of therapy [J].
Bajaj, G. K. ;
Teslow, T. ;
Yu, M. H. ;
Lee, D. J. ;
Ford, E. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03) :S456-S456
[3]   Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT/linear accelerator system [J].
Barker, JL ;
Garden, AS ;
Ang, KK ;
O'Daniel, JC ;
Wang, H ;
Court, LE ;
Morrison, WH ;
Rosenthal, DI ;
Chao, KSC ;
Tucker, SL ;
Mohan, R ;
Dong, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04) :960-970
[4]   MV cone-beam CT to monitor Anatomic changes in patients with head and neck cancers during radiation treatment [J].
Bucci, M ;
Gillis, A ;
Morin, O ;
Chen, J ;
Aubin, M ;
Xia, P ;
Pouliot, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :S357-S358
[5]   Dose-response relationships within the parotid gland after radiotherapy for head and neck cancer [J].
Bussels, B ;
Maes, A ;
Flamen, P ;
Lambin, P ;
Erven, K ;
Hermans, R ;
Nuyts, S ;
Weltens, C ;
Cecere, S ;
Lesaffre, E ;
Van den Bogaert, W .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (03) :297-306
[6]  
Chui C S, 2001, Med Dosim, V26, P189, DOI 10.1016/S0958-3947(01)00069-3
[7]   Intensity-modulated radiation therapy: A clinical perspective - Introduction [J].
Eisbruch, A .
SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) :197-198
[8]   Effect of regression of enlarged neck lymph nodes on radiation doses received by parotid glands during intensity-modulated radiotherapy for head and neck cancer [J].
Kuo, Yu-Cheng ;
Wu, Tung-Ho ;
Chung, Tao-Sang ;
Huang, Kuang-Wei ;
Chao, K. S. Clifford ;
Su, Wen-Chuan ;
Chiou, Jeng-Fong .
AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2006, 29 (06) :600-605
[9]   Anatomy changes in radiotherapy detected using portal imaging [J].
McDermott, Leah N. ;
Wendling, Markus ;
Sonke, Jan-Jakob ;
van Herk, Marcel ;
Mijnheer, Ben J. .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) :211-217
[10]   Measurement of IMRT head and neck setup error using an on-board kilovoltage imager [J].
Mechalakos, J ;
Hunt, M ;
Hong, L ;
Lee, N ;
Narayana, A ;
Chong, L ;
Ling, CC ;
Amols, H .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02) :S353-S354