A STUDY OF THE HEAT FLUX OF U-PIPE GROUND HEAT EXCHANGER

被引:0
|
作者
Zhang, Changxing [1 ]
Hu, Songtao [1 ]
Liu, Guodan [1 ]
机构
[1] Xian Univ Architecture & Technol, Sch Environm & Municipal Engn, Xian, Peoples R China
来源
FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS | 2009年
关键词
Ground heat exchanger (GHE); Thermal resistance; Heat flux; THERMAL PERFORMANCE;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ground heat exchanger (GHE) coupled heat pumps constitute an alternative system for the air conditioning of buildings, with the vertical U-pipe being the most popular. With the aid of GHE, heat is exchanged between the fluid of the primary circuit of the heat pump and ground. Therefore, the designing and dimensioning of GHE are sensitive to the installation cost and the overall performance of the system, which makes it critical to calculate the heat flux per meter of borehole (HFPMB) that GHE can handle. Recently, significant research effort has been devoted in quantifying the effect some properties (ground, drilling and the ground temperature) have on the GHE performance so that the HFPMB can be calculated accurately according to the specific site of installation. This paper presents a calculation algorithm, by which the factors of impact on HFPMB in vertical GHE is analyzed. Firstly, heat transfer analysis of boreholes in vertical GHE is made according to its configuration, especially; the thermal resistance is deduced by the quasi-three-dimensional model, which is crucial to calculate HFPMB. Secondly, a suitable calculation algorithm is developed, which determines HFPMB as a function of the duration of the load. Iterative algorithm is applied in the solution for HFPMB. Based on the finite line source model, the borehole wall temperature as a medium parameter is calculated corresponding to a supposed HFPMB. In succession, the other HFPMB can be calculated by analysis on the heat transfer between fluid in U-pipe and the borehole wall corresponding to the resistance of the specific configuration under constant inlet water temperature of GHE. Until the difference between the two HFPMB is less than 1e-6, the iterative calculation finished and the calculated HFPMB can be determined in MATLAB. Many parameters are applied during the iterative calculation, but the computational time is short and the physical concept is legible. According to the calculated results from the algorithm, the impacts of inlet water temperature, water flow rate and borehole depth on HFPMB are analyzed corresponding to different inputs respectively. The iterative algorithm of HFPMB presented. in this paper can be applied to calculate accurately the dimensions of GHE according to ground parameters, and analysis on the three factors is helpful to choose capacity of heat pump and circulating pump, which can make the system operate efficiently and minimize the adverse effects on the installation cost of GCHP.
引用
收藏
页码:2226 / 2233
页数:8
相关论文
共 50 条
  • [21] Double U-pipe Borehole Heat Exchangers: sensitivity analysis of their energy efficiency
    Casasso, Alessandro
    Sethi, Rajandrea
    GEAM-GEOINGEGNERIA AMBIENTALE E MINERARIA-GEAM-GEOENGINEERING ENVIRONMENT AND MINING, 2014, (141): : 51 - 62
  • [22] Heat transfer of horizontal parallel pipe ground heat exchanger and experimental verification
    Demir, Hakan
    Koyun, Ahmet
    Temir, Galip
    APPLIED THERMAL ENGINEERING, 2009, 29 (2-3) : 224 - 233
  • [23] Vertical U-pipe flow characteristics in absorption heat pump: Experimental study under vacuum conditions
    Zhu, Chaoyi
    Xie, Xiaoyun
    Jiang, Yi
    APPLIED THERMAL ENGINEERING, 2020, 172
  • [24] Study of Gas-to-Liquid Heat Pipe Heat Exchanger
    Gupta, Pratik Prakash
    Senthilkumar, Sundararaj
    Kang, Shung-Wen
    PROCESSES, 2022, 10 (05)
  • [25] Effects of ground heat exchanger variable pipe separation in ground-source heat pump systems
    Makasis, N.
    Narsilio, G. A.
    Bidarmaghz, A.
    Johnston, I. W.
    ENERGY GEOTECHNICS, 2016, : 155 - 161
  • [26] Applicability of the pipe structure and flow velocity of vertical ground heat exchanger for ground source heat pump
    Zhou, Hong
    Lv, Jian
    Li, Tailu
    ENERGY AND BUILDINGS, 2016, 117 : 109 - 119
  • [27] Optimization of Circumferential Temperature Uniformity of a PTC Absorber with U-pipe Exchanger
    Mohammed, Halimi
    Ayoub, Oumachtaq
    Choukri, Messaoudi
    Aumeur, El Amrani
    PROCEEDINGS OF 2021 9TH INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC), 2021, : 377 - 380
  • [28] Comparison of the thermal performance of double U-pipe borehole heat exchangers measured in situ
    Pahud, D
    Matthey, B
    ENERGY AND BUILDINGS, 2001, 33 (05) : 503 - 507
  • [29] Experimental investigation of absorbed flux circumferential distribution of an absorber with U-pipe tube exchanger for Parabolic Trough Collectors
    Halimi, Mohammed
    Outana, Imane
    Diouri, Jaouad
    El Amrani, Aumeur
    Messaoudi, Choukri
    APPLIED THERMAL ENGINEERING, 2018, 129 : 1230 - 1239
  • [30] Study on heat transfer effect of single U-shaped buried pipe heat exchanger in Karst area
    Yang B.
    Pei P.
    Luo T.
    Hao D.
    Wang C.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (12): : 510 - 519