Model-based RSA of a femoral hip stem using surface and geometrical shape models

被引:50
作者
Kaptein, Bart L.
Valstar, Edward R.
Spoor, Cees W.
Stoel, Berend C.
Rozing, Piet M.
机构
[1] Leiden Univ, Med Ctr, Dept Orthopaed, NL-2300 RC Leiden, Netherlands
[2] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, Delft, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, Div Image Proc LKEB, Leiden, Netherlands
关键词
D O I
10.1097/01.blo.0000224010.04551.14
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Roentgen stereophotogrammetry (RSA) is a highly accurate three-dimensional measuring technique for assessing micromotion of orthopaedic implants. A drawback is that markers have to be attached to the implant. Model-based techniques have been developed to prevent using special marked implants. We compared two model-based RSA methods with standard marker-based RSA techniques. The first model-based RSA method used surface models, and the second method used elementary geometrical shape (EGS) models. We used a commercially available stem to perform experiments with a phantom as well as reanalysis of patient RSA radiographs. The data from the phantom experiment indicated the accuracy and precision of the elementary geometrical shape model-based RSA method is equal to marker-based RSA. For model-based RSA using surface models, the accuracy is equal to the accuracy of marker-based RSA, but its precision is worse. We found no difference in accuracy and precision between the two model-based RSA techniques in clinical data. For this particular hip stem, EGS model-based RSA is a good alternative for marker-based RSA.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 17 条
[1]   INSTABILITY AND WEAR OF TOTAL HIP PROSTHESES DETERMINED WITH ROENTGEN STEREOPHOTOGRAMMETRY [J].
BALDURSSON, H ;
EGUND, N ;
HANSSON, LI ;
SELVIK, G .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1979, 95 (04) :257-263
[2]   The precision of radiostereometric measurements.: Manual vs. digital measurements [J].
Börlin, N ;
Thien, T ;
Kärrholm, J .
JOURNAL OF BIOMECHANICS, 2002, 35 (01) :69-79
[4]   Evaluation of three pose estimation algorithms for model-based Roentgen stereophotogrammetric analysis [J].
Kaptein, BL ;
Valstar, ER ;
Stoel, BC ;
Rozing, PM ;
Reiber, JHC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2004, 218 (H4) :231-238
[5]   A new model-based RSA method validated using CAD models and models from reversed engineering [J].
Kaptein, BL ;
Valstar, ER ;
Stoel, BC ;
Rozing, PM ;
Reiber, JHC .
JOURNAL OF BIOMECHANICS, 2003, 36 (06) :873-882
[6]  
Kiss J, 1995, Proc Inst Mech Eng H, V209, P169, DOI 10.1243/PIME_PROC_1995_209_340_02
[7]   CHRONIC LATERAL INSTABILITY OF THE ANKLE - ROENTGEN STEREOPHOTOGRAMMETRY OF TALAR POSITION [J].
LOFVENBERG, R ;
KARRHOLM, J ;
SELVIK, G ;
HANSSON, LI ;
AHLGREN, O .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (01) :34-39
[8]  
Ranstam J, 2000, ACTA ORTHOP SCAND, V71, P106
[9]  
Snorrason F, 1990, J Arthroplasty, V5, P217, DOI 10.1016/S0883-5403(08)80076-9
[10]   An SQP method for general nonlinear programs using only equality constrained subproblems [J].
Spellucci, P .
MATHEMATICAL PROGRAMMING, 1998, 82 (03) :413-448