Automatic control and safety concepts for extracorporeal lung support

被引:4
作者
Kopp, Ruedger [1 ]
Walter, Marian [2 ]
Arens, Jutta [3 ]
Stollenwerk, Andre [4 ]
Leonhardt, Steffen [2 ]
Schmitz-Rode, Thomas [3 ]
Kowalewski, Stefan [4 ]
Rossaint, Rolf [1 ,5 ]
机构
[1] Univ Klinikum Aachen, Rhein Westfal TH Aachen, Fachubergreifende Klin Operat Intens Med, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Helmholtz Inst, Lehrstuhl Med Informat Tech, Aachen, Germany
[3] Rhein Westfal TH Aachen, Helmholtz Inst, Lehrstuhl Angew Med Tech, Aachen, Germany
[4] Rhein Westfal TH Aachen, Lehrstuhl Informat 11, Aachen, Germany
[5] Univ Klinikum Aachen, Rhein Westfal TH Aachen, Anasthesiol Klin, D-52074 Aachen, Germany
来源
BIOMEDIZINISCHE TECHNIK | 2009年 / 54卷 / 05期
关键词
acute respiratory distress syndrome; automation; control engineering; extracorporeal lung support; extracorporeal membrane oxygenation; model-based safety concepts; RESPIRATORY-DISTRESS-SYNDROME; PHYSIOLOGICAL CONTROL; LIFE-SUPPORT; BLOOD PUMPS; ASSIST; SYSTEM; TRANSPLANTATION; OXYGENATOR; EXPERIENCE; DIAGNOSIS;
D O I
10.1515/BMT.2009.036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In some cases of severe acute respiratory distress syndrome, hypoxemia occurs despite optimized conservative therapy; however, extracorporeal membrane oxygenation (ECMO) can assure sufficient gas exchange. To increase safety and reliability of devices, the oxygenator design was optimized integrating new plasma-resistant composite membranes and new blood pumps are used with longer durability and reduced blood cell damage. Another approach is the use of an arterio-venous pumpless extracorporeal lung assist (pECLA) using an oxygenator with reduced pressure drop to simplify management and to avoid pump-related complications. First attempts were made to integrate basic control and safety concepts in ECMO circuits, but this does not seem to be sufficient to overcome the specific problems of ECMO (long-term use and limited supervision of the intensive care unit). The integration of sophisticated automated control and safety concepts in combination with revised ECMO circuits could allow a more reliable application of ECMO of the intensive care unit without continuous observation by a perfusionist. Easier intra- and interhospital transfer of patients with running ECMO would be another advantage.
引用
收藏
页码:289 / 297
页数:9
相关论文
共 52 条
[1]  
Alkalai L, 1998, COMPUTER, V31, P37
[2]   DEVELOPMENT OF A DIGITAL ADAPTIVE-CONTROL SYSTEM FOR PO2 REGULATION IN A MEMBRANE-OXYGENATOR [J].
ALLEN, J ;
FISHER, AC ;
GAYLOR, JDS ;
RAZIEH, AR .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (05) :404-411
[3]   First experiences with a new miniaturised life support system for mobile percutaneous cardiopulmonary bypass [J].
Arlt, Matthias ;
Philipp, Alois ;
Zimmermann, Markus ;
Voelkel, Sabine ;
Hilker, Michael ;
Hobbhahn, Jonny ;
Schmid, Christof .
RESUSCITATION, 2008, 77 (03) :345-350
[4]   A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller [J].
Asama, J ;
Shinshi, T ;
Hoshi, H ;
Takatani, S ;
Shimokohbe, A .
ARTIFICIAL ORGANS, 2006, 30 (03) :160-167
[5]  
BECKSCHULZE E, FAULT HANDLING APPRO, P82
[6]   A new pumpless extracorporeal interventional lung assist in critical hypoxemia/hypercapnia [J].
Bein, T ;
Weber, F ;
Philipp, A ;
Prasser, C ;
Pfeifer, M ;
Schmid, FX ;
Butz, B ;
Birnbaum, D ;
Taeger, K ;
Schlitt, HJ .
CRITICAL CARE MEDICINE, 2006, 34 (05) :1372-1377
[7]   Pump-induced haemolysis: a comparison of short-term ventricular assist devices [J].
Bennett, M ;
Horton, S ;
Thuys, C ;
Augustin, S ;
Rosenberg, M ;
Brizard, C .
PERFUSION-UK, 2004, 19 (02) :107-111
[8]  
Birnbaum D, 1997, Biomed Tech (Berl), V42 Suppl, P313, DOI 10.1515/bmte.1997.42.s2.313
[9]  
CHAUVEAU N, 1992, P IEEE EMBS, V14, P377
[10]   Arteriovenous extracorporeal carbon dioxide removal - A mathematical model and experimental evaluation [J].
Conrad, SA ;
Brown, EG ;
Grier, LR ;
Baier, J ;
Blount, J ;
Heming, T ;
Zwischenberger, JB ;
Bidani, A .
ASAIO JOURNAL, 1998, 44 (04) :267-277