Ultrasound-Guided Fine-Needle Aspiration With Optional Core Needle Biopsy of Head and Neck Lymph Nodes and Masses: Comparison of Diagnostic Performance in Treated Squamous Cell Cancer Versus All Other Lesions

被引:9
|
作者
Wagner, Jason M. [1 ]
Monfore, Natosha [1 ]
McCullough, Austin J. [4 ]
Zhao, Lichao [2 ]
Conrad, Rachel D. [2 ]
Krempl, Greg A. [3 ]
Alleman, Anthony M. [1 ]
机构
[1] Univ Oklahoma, Hlth Sci Ctr, Dept Radiol Sci, 940 NE 13th St,4G-4250, Oklahoma City, OK 73104 USA
[2] Univ Oklahoma, Hlth Sci Ctr, Dept Pathol, Oklahoma City, OK USA
[3] Univ Oklahoma, Hlth Sci Ctr, Dept Otorhinolaryngol, Oklahoma City, OK USA
[4] Univ Oklahoma, Hlth Sci Ctr, Coll Med, Oklahoma City, OK 73190 USA
关键词
cervical lymph node; core needle biopsy; fine-needle aspiration; squamous cell carcinoma; ultrasound; CYTOLOGY; ACCURACY; ADEQUACY; US;
D O I
10.1002/jum.14918
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To evaluate the diagnostic performance of ultrasound (US)-guided fine-needle aspiration with optional core needle biopsy of head and neck lymph nodes and masses, with attention to differences between biopsy of treated squamous cell carcinoma (SCC) and biopsy of other lesions. Methods Institutional Review Board approval was obtained, and the need for consent was waived for this retrospective study. All 861 US-guided biopsies of head and neck lymph nodes and masses performed between March 1, 2012, and May 16, 2016, were reviewed. Results Of the 861 biopsies, 53 targeted SCC with residual masses after treatment. The biopsy procedures yielded benign or malignant pathologic results in 71.7% (38 of 53) of treated SCC and 90.7% (733 of 808) of all other lesions (P < .001). A reference standard based on subsequent pathologic results or clinical and imaging follow-up was established in 68.4% of procedures. In cases with benign or malignant biopsy results and a subsequent reference standard, the sensitivity values for malignancy were 87.5% (95% confidence interval, 64.0%-96.5%) in treated SCC and 98.3% (95% confidence interval, 96.0%-99.3%) in all other cases (P = .047), and the specificity values were 63.6% (95% confidence interval, 35.4%-84.8%) in treated SCC and 99.5% (95% confidence interval, 97.3%-99.9%) in all other cases (P < .001). There were no major complications related to the biopsy procedures. Conclusions Excluding treated SCC, US-guided fine-needle aspiration with optional core needle biopsy of head and neck lymph nodes and masses has excellent diagnostic performance. Needle biopsy of head and neck SCC with a residual mass after therapy has a high rate of nondiagnostic samples, suboptimal sensitivity, and poor specificity.
引用
收藏
页码:2275 / 2284
页数:10
相关论文
共 50 条
  • [31] Endoscopic ultrasound guided fine-needle aspiration vs core needle biopsy for solid pancreatic lesions: Comparison of diagnostic accuracy and procedural efficiency
    Syed, Aslam
    Babich, Olivia
    Rao, Bharat
    Singh, Shailendra
    Carleton, Neil
    Gulati, Abhishek
    Kulkarni, Archana
    Garg, Mrinal
    Farah, Katie
    Kochhar, Gursimran
    Morrissey, Suzanne
    Mitre, Marcia
    Kulkarni, Abhijit
    Dhawan, Manish
    Silverman, Jan F.
    Pharaon, Majed
    Thakkar, Shyam
    DIAGNOSTIC CYTOPATHOLOGY, 2019, 47 (11) : 1138 - 1144
  • [32] Initial staging of the neck in head and neck squamous cell carcinoma: A comparison of CT, PET/CT, and ultrasound-guided fine-needle aspiration cytology
    Stoeckli, Sandro J.
    Haerle, Stephan K.
    Strobel, Klaus
    Haile, Sarah R.
    Hany, Thomas F.
    Schuknecht, Bernhard
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2012, 34 (04): : 469 - 476
  • [33] Fine-needle aspiration cytology versus core needle lymph node biopsy in axillary staging of breast cancer
    Omar M. Mahmoud
    Mai El-MoatazBellah Khedrawy
    Hasan Ibrahim Megally
    Mahmoud Farouk Mohamed
    Momtaz Thabet Allam
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [34] Maximizing the Diagnostic Yield of Endoscopic Ultrasound-Guided Fine-Needle Aspiration Biopsy
    Artifon, Everson L. A.
    Guedes, Hugo G.
    Cheng, Spencer
    GASTROENTEROLOGY, 2017, 153 (04) : 881 - 885
  • [35] The role of ultrasound and ultrasound-guided fine needle aspiration biopsy of lymph nodes in patients with skin tumours
    Solivetti, Francesco Maria
    Elia, Fulvia
    Santaguida, Maria Giulia
    Guerrisi, Antonino
    Visca, Paolo
    Cercato, Maria Cecilia
    Di Carlo, Aldo
    RADIOLOGY AND ONCOLOGY, 2014, 48 (01) : 29 - 34
  • [36] Evaluation of endoscopic ultrasound-guided fine-needle aspiration biopsy for pancreatic lesions
    Min, Chenzhi
    Xing, Jianghai
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 881 - 881
  • [37] Contribution of ultrasound-guided fine-needle aspiration cell blocks of metastatic supraclavicular lymph nodes to the diagnosis of lung cancer
    Tian, Hai-Ying
    Xu, Dong
    Liu, Jun-Ping
    Mao, Wei-Min
    Chen, Li-Yu
    Yang, Chen
    Wang, Li-Ping
    Shi, Kai-Yuan
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2015, 11 (08) : 234 - 238
  • [38] Contribution of endoscopic ultrasound-guided fine-needle aspiration in the workup of mediastinal lymph nodes
    Salom, F.
    Mangialavori, L.
    Roseau, G.
    Chaussade, S.
    Prat, F.
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2010, 34 (01): : 88 - 94
  • [39] Ultrasound-guided fine-needle aspiration of axillary lymph nodes in breast cancer: Diagnostic accuracy and role in surgical management
    Iwamoto, Naoko
    Aruga, Tomoyuki
    Horiguchi, Shinichiro
    Asami, Hidekazu
    Saita, Chiaki
    Onishi, Mai
    Goto, Risa
    Ishiba, Toshiyuki
    Honda, Yayoi
    Miyamoto, Hiromi
    Kuroi, Katsumasa
    DIAGNOSTIC CYTOPATHOLOGY, 2019, 47 (08) : 788 - 792
  • [40] False-negative ultrasound-guided fine-needle aspiration of axillary lymph nodes in breast cancer patients
    Iwamoto, Naoko
    Aruga, Tomoyuki
    Asami, Hidekazu
    Horiguchi, Shin-ichiro
    CYTOPATHOLOGY, 2020, 31 (05) : 463 - 467