Energy and exergy analysis of forced and natural convection indirect solar dryers: Estimation of exergy inflow, outflow, losses, exergy efficiencies and sustainability indicators from drying experiments

被引:136
作者
Mugi, Vishnuvardhan Reddy [1 ]
Chandramohan, V. P. [1 ]
机构
[1] Natl Inst Technol Warangal, Mech Engn Dept, Warangal 506004, Telangana, India
关键词
Indirect solar dryer; Forced and natural convection; Energy and exergy analysis; Improvement potential; Exergy efficiency; THERMODYNAMIC ANALYSIS; KINETICS; PERFORMANCE; LEAVES;
D O I
10.1016/j.jclepro.2020.124421
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, energy and exergy analysis (EEA) was performed during drying of okra (Abelmoschus esculentus) in an indirect solar dryer (ISD) under forced and natural convection and results were compared for better assessment of the performance of ISD and optimize the drying process by considering the quantity of energy. A divergent duct integrated with central processing unit (CPU) fans was attached to solar air collector (SAC) in forced convection ISD and this fitting was removed during natural convection experiments. The average SAC and drying efficiencies were 74.98% and 24.95% under forced convection and the same were 61.49% and 20.13% under natural convection, respectively. The exergy inflow, outflow and losses were determined for the collector and drying chamber for both setups. The exergy outflow of SAC was in a range of 1.04-46.85 W and 1.13-50.94 W, in forced and natural convection mode, respectively. The exergy loss for the drying chamber varied from 0.062 to 21.99 W and 0.394-24.99 W, under forced and natural convection, respectively. The values of average exergy efficiencies for SAC and drying chamber in forced convection ISD were 2.03 and 59.32%, while in natural convection, these were 2.44 and 55.45%, respectively. In forced convection ISD, the improvement potential was in the range of 0.0095-10.51 W while the sustainability index and waste exergy ratio varied from 1.19 to 17.05 and 0.06 to 0.83, respectively. EEA analysis revealed that the performance of forced convection was better than the natural convection ISD. Uncertainty of all parameters was estimated and updated in all plots in terms of error bars. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:15
相关论文
共 32 条
[1]   Energy and exergy analysis of a flat-plate solar air heater coated with carbon nanotubes and cupric oxide nanoparticles embedded in black paint [J].
Abdelkader, Tarek Kh ;
Zhang, Yanlin ;
Gaballah, Eid S. ;
Wang, Shaowei ;
Wan, Qiang ;
Fan, Qizhou .
JOURNAL OF CLEANER PRODUCTION, 2020, 250
[2]   Numerical analysis on solar air collector provided with artificial square shaped roughness for indirect type solar dryer [J].
Abhay, L. ;
Chandramohan, V. P. ;
Raju, V. R. K. .
JOURNAL OF CLEANER PRODUCTION, 2018, 190 :353-367
[3]   Energy, exergy, economic and environmental (4E) analyses of flat-plate and V-groove solar air collectors based on aluminium and copper [J].
Abuska, Mesut ;
Sevik, Seyfi .
SOLAR ENERGY, 2017, 158 :259-277
[4]   Drying of mint leaves in a solar dryer and under open sun: Modelling, performance analyses [J].
Akpinar, E. Kayak .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (12) :2407-2418
[5]   The effects of some exergetic indicators on the performance of thin layer drying process of long green pepper in a solar dryer [J].
Akpinar, Ebru Kavak .
HEAT AND MASS TRANSFER, 2019, 55 (02) :299-308
[7]  
Cengel Y. A., 2006, Thermodynamics: An Engineering Approach, 5th Ed, V5th
[8]   Decoupling or delusion? Mapping carbon emission per capita based on the human development index in Southwest China [J].
Chen, Liu ;
Cai, Weiguang ;
Ma, Minda .
SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 741
[9]   Energy and exergy analysis of the solar drying of jackfruit leather [J].
Chowdhury, M. M. I. ;
Bala, B. K. ;
Haque, M. A. .
BIOSYSTEMS ENGINEERING, 2011, 110 (02) :222-229
[10]   Microwave drying kinetics of okra [J].
Dadali, Gokce ;
Apar, Dilek Kilic ;
Ozbek, Belma .
DRYING TECHNOLOGY, 2007, 25 (4-6) :917-924