2-D SHEAR WAVE ELASTOGRAPHY FOR FOCAL LESIONS IN LIVER PHANTOMS: EFFECTS OF BACKGROUND STIFFNESS, DEPTH AND SIZE OF FOCAL LESIONS ON STIFFNESS MEASUREMENT

被引:9
作者
Hwang, Jeong Ah [1 ]
Jeong, Woo Kyoung [2 ,3 ]
Song, Kyoung Doo [2 ,3 ]
Kang, Kyung A. [4 ]
Lim, Hyo K. [2 ,3 ]
机构
[1] Soonchunhyang Univ, Cheonan Hosp, Dept Radiol, Coll Med, Cheonan, Chungcheongnam, South Korea
[2] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[3] Sungkyunkwan Univ, Ctr Imaging Sci, Samsung Med Ctr, Sch Med, 81 Irwon Ro, Seoul 06351, South Korea
[4] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Sch Med, Seoul, South Korea
关键词
Elasticity imaging techniques; Ultrasonography; Elastic modulus; Phantoms; imaging; Liver neoplasms; TOUCH TISSUE QUANTIFICATION; SOLID BREAST MASSES; DIFFERENT FREQUENCIES; RELIABLE MEASUREMENT; ULTRASOUND; DIAGNOSIS; BENIGN; VARIABILITY; ACCURACY; FIBROSIS;
D O I
10.1016/j.ultrasmedbio.2019.08.006
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of this study was to determine the factors influencing stiffness and conspicuity of focal lesions in deep organs by focusing on target properties using 2-D shear wave elastography (SWE). Two normal (4 +/- 1 kPa) and cirrhotic (16 +/- 2 kPa) liver-mimicking phantoms with spherical inclusions (23 +/- 3 kPa) were used. Inclusions of three sizes (20, 15 and 10 mm in diameter) were arranged in a row at depths of 3, 5 and 7 cm. Two observers acquired quantitative stiffness values and a qualitative five-grade morphologic score at each inclusion using SWE. The coefficients of variation (CVs) of stiffness were calculated to assess measurement reliability. The generalized estimating equation was used to identify whether stiffness, CV and morphologic score were independent of background stiffness, depth and size of inclusions and observer. In the quantitative assessment, stiffness of the inclusion and CV were dependent on the type of phantom and depth of inclusion (p < 0.001). There were no significant differences in stiffness and CV according to the observer. Morphologic score differed significantly only in the size of the inclusion (p < 0.001). When the depth of the inclusion was 7 cm, the stiffness was the highest, and the 10 mm-sized inclusions had lower morphologic scores than the other inclusions (all p values < 0.001). In conclusion, 2-D SWE assessment of focal lesions could be affected by background stiffness and depth of focal lesions, and may be limited in evaluating focal hepatic lesions. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:3261 / 3268
页数:8
相关论文
共 34 条
  • [1] Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement
    Barr, Richard G.
    Ferraioli, Giovanna
    Palmeri, Mark L.
    Goodman, Zachary D.
    Garcia-Tsao, Guadalupe
    Rubin, Jonathan
    Garra, Brian
    Myers, Robert P.
    Wilson, Stephanie R.
    Rubens, Deborah
    Levine, Deborah
    [J]. RADIOLOGY, 2015, 276 (03) : 845 - 861
  • [2] Supersonic shear imaging: A new technique for soft tissue elasticity mapping
    Bercoff, J
    Tanter, M
    Fink, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (04) : 396 - 409
  • [3] Shear-wave Elastography Improves the Specificity of Breast US: The BE1 Multinational Study of 939 Masses
    Berg, Wendie A.
    Cosgrove, David O.
    Dore, Caroline J.
    Schaefer, Fritz K. W.
    Svensson, William E.
    Hooley, Regina J.
    Ohlinger, Ralf
    Mendelson, Ellen B.
    Balu-Maestro, Catherine
    Locatelli, Martina
    Tourasse, Christophe
    Cavanaugh, Barbara C.
    Juhan, Valerie
    Stavros, A. Thomas
    Tardivon, Anne
    Gay, Joel
    Henry, Jean-Pierre
    Cohen-Bacrie, Claude
    [J]. RADIOLOGY, 2012, 262 (02) : 435 - 449
  • [4] Variability of ShearWave Velocity using Different Frequencies in Acoustic Radiation Force Impulse (ARFI) Elastography: A Phantom and Normal Liver Study
    Chang, S.
    Kim, M. -J.
    Kim, J.
    Lee, M. -J.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2013, 34 (03): : 260 - 265
  • [5] Shear wave elastography for breast masses is highly reproducible
    Cosgrove, David O.
    Berg, Wendie A.
    Dore, Caroline J.
    Skyba, Danny M.
    Henry, Jean-Pierre
    Gay, Joel
    Cohen-Bacrie, Claude
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (05) : 1023 - 1032
  • [6] Dietrich CF, 2017, ULTRASCHALL MED, V38, pE16, DOI 10.1055/s-0043-103952
  • [7] Differentiating benign from malignant solid breast masses: value of shear wave elastography according to lesion stiffness combined with greyscale ultrasound according to BI-RADS classification
    Evans, A.
    Whelehan, P.
    Thomson, K.
    Brauer, K.
    Jordan, L.
    Purdie, C.
    McLean, D.
    Baker, L.
    Vinnicombe, S.
    Thompson, A.
    [J]. BRITISH JOURNAL OF CANCER, 2012, 107 (02) : 224 - 229
  • [8] LIVER ULTRASOUND ELASTOGRAPHY: AN UPDATE TO THE WORLD FEDERATION FOR ULTRASOUND IN MEDICINE AND BIOLOGY GUIDELINES AND RECOMMENDATIONS
    Ferraioli, Giovanna
    Wong, Vincent Wai-Sun
    Castera, Laurent
    Berzigotti, Annalisa
    Sporea, Loan
    Dietrich, Christoph F.
    Choi, Byung Ihn
    Wilson, Stephanie R.
    Kudo, Masatoshi
    Barr, Richard G.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (12) : 2419 - 2440
  • [9] Accuracy of Real-Time Shear Wave Elastography for Assessing Liver Fibrosis in Chronic Hepatitis C: A Pilot Study
    Ferraioli, Giovanna
    Tinelli, Carmine
    Dal Bello, Barbara
    Zicchetti, Mabel
    Filice, Gaetano
    Filice, Carlo
    [J]. HEPATOLOGY, 2012, 56 (06) : 2125 - 2133
  • [10] Evaluation of 2D-Shear Wave Elastography for Characterisation of Focal Liver Lesions
    Gerber, Ludmila
    Fitting, Daniel
    Srikantharajah, Kajana
    Weiler, Nina
    Kyriakidou, Georgia
    Bojunga, Joerg
    Schulze, Falko
    Bone, Dimitra
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    [J]. JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2017, 26 (03) : 283 - 290