The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo

被引:28
作者
Byakova, S. F. [1 ]
Novozhilova, N. E. [1 ]
Makeeva, I. M. [1 ]
Grachev, V. I. [2 ]
Kasatkina, I. V. [3 ]
机构
[1] Sechenov Univ, IM Sechenov Moscow State Med Univ 1, Fed State Autonomous Educ Inst Higher Educ, Dept Therapeut Dent,Minist Hlth Russian Federat, Narodnogo Opolcheniya St 42-3-9, Moscow 123298, Russia
[2] 3D Lab, Independent Xray Diagnost Lab, Moscow, Russia
[3] RAS, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
关键词
cone-beam computed tomography; diagnosis; vertical root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; FILLED TEETH; VITRO; PREVALENCE; DENTIN; POSTS; AGE;
D O I
10.1111/iej.13114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results The average sensitivity of CBCT for the diagnosis of VRFs was 0.84 +/- 0.2. The accuracy and AUC values were 0.81 +/- 0.08 and 0.84 +/- 0.17, respectively. The sensitivity, accuracy and AUC values for the detection of VRFs were significantly lower: 0.17 +/- 0.24 (P = 0.042), 0.54 +/- 0.07 (P = 0.043), and 0.52 +/- 0.09 (P = 0.043), respectively. The specificity of CBCT for the detection and diagnosis of VRFs did not differ significantly (P = 0.50). Conclusion Cone-beam computed tomography was helpful in VRF diagnosis even when it was not possible to visualize the fracture line.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 50 条
  • [31] Does anthropomorphic model design in ex vivo studies affect diagnostic accuracy for dental root fracture using CBCT?
    Yalda, Fedil Andraws
    Clarkson, Rosalyn J.
    Davies, Jonathan
    Rout, Peter G. J.
    Sengupta, Anita
    Horner, Keith
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2020, 49 (07)
  • [32] Vertical Root Fractures and Dentin Defects: Effects of Root Canal Preparation, Filling, and Mechanical Cycling
    Barreto, Mirela Sangoi
    Moraes, Rafael do Amaral
    da Rosa, Ricardo Abreu
    Cunha Moreira, Carlos Heitor
    Reis So, Marcus Vinicius
    Souza Bier, Carlos Alexandre
    [J]. JOURNAL OF ENDODONTICS, 2012, 38 (08) : 1135 - 1139
  • [33] Accuracy of High-resolution Small-volume Cone-Beam Computed Tomography in the Diagnosis of Vertical Root Fracture: An In Vivo Analysis
    Dias, Debora R.
    Iwaki, Lilian C., V
    de Oliveira, Alexandre C. A.
    Martinhao, Felipe S.
    Rossi, Robson M.
    Araujo, Mauricio G.
    Hayacibara, Roberto M.
    [J]. JOURNAL OF ENDODONTICS, 2020, 46 (08) : 1059 - 1066
  • [34] Diagnosis of Vertical Root Fractures in Endodontically Treated Teeth by Cone-Beam Computed Tomography
    Mizuhashi, Fumi
    Watarai, Yuko
    Ogura, Ichiro
    [J]. JOURNAL OF IMAGING, 2022, 8 (03)
  • [35] Diagnosis of vertical root fractures with optical coherence tomography
    Shemesh, Hagay
    van Soest, Gis
    Wu, Min-Kai
    Wesselink, Paul R.
    [J]. JOURNAL OF ENDODONTICS, 2008, 34 (06) : 739 - 742
  • [36] Digital subtraction radiography in detection of vertical root fractures: accuracy evaluation for root canal filling, fracture orientation and width variables. An ex-vivo study
    Vasileios Kapralos
    Andreas Koutroulis
    Eleni Irinakis
    Pantelis Kouros
    Kleoniki Lyroudia
    Ioannis Pitas
    Georgios Mikrogeorgis
    [J]. Clinical Oral Investigations, 2020, 24 : 3671 - 3681
  • [37] Accuracy of Different Imaging CBCT Systems for the Detection of Natural External Radicular Resorption Cavities: An Ex Vivo Study
    Deliga Schroder, Angela Graciela
    Westphalen, Fernando Henrique
    Schroder, Julio Cesar
    Fernandes, Angela
    Ditzel Westphalen, Vania Portela
    [J]. JOURNAL OF ENDODONTICS, 2019, 45 (06) : 761 - 767
  • [38] Accuracy and Reliability of CBCT Compared to Clinical Probing in Detection of Trifurcation Defects: An In Vivo Study
    Alsakr, Abdulaziz Mohammad
    Creanga, Adriana G.
    Alqahtani, Abdullah Saad
    Gufran, Khalid
    [J]. BIOMED RESEARCH INTERNATIONAL, 2022, 2022
  • [39] Performance of Bioceramic-based Root Filling Material with Artifact Reduction Properties in the Detection of Vertical Root Fractures Using Cone-beam Computed Tomography
    Bahmani, Ali
    Karkehabadi, Hamed
    Shokri, Abbas
    Farhadian, Maryam
    [J]. OPEN DENTISTRY JOURNAL, 2021, 15 : 170 - 175
  • [40] Differential diagnosis of vertical root fractures using reconstructed three-dimensional models of bone defects
    Komatsu, K.
    Abe, Y.
    Yoshioka, T.
    Ishimura, H.
    Ebihara, A.
    Suda, H.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (08)