The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo

被引:28
作者
Byakova, S. F. [1 ]
Novozhilova, N. E. [1 ]
Makeeva, I. M. [1 ]
Grachev, V. I. [2 ]
Kasatkina, I. V. [3 ]
机构
[1] Sechenov Univ, IM Sechenov Moscow State Med Univ 1, Fed State Autonomous Educ Inst Higher Educ, Dept Therapeut Dent,Minist Hlth Russian Federat, Narodnogo Opolcheniya St 42-3-9, Moscow 123298, Russia
[2] 3D Lab, Independent Xray Diagnost Lab, Moscow, Russia
[3] RAS, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
关键词
cone-beam computed tomography; diagnosis; vertical root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; FILLED TEETH; VITRO; PREVALENCE; DENTIN; POSTS; AGE;
D O I
10.1111/iej.13114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results The average sensitivity of CBCT for the diagnosis of VRFs was 0.84 +/- 0.2. The accuracy and AUC values were 0.81 +/- 0.08 and 0.84 +/- 0.17, respectively. The sensitivity, accuracy and AUC values for the detection of VRFs were significantly lower: 0.17 +/- 0.24 (P = 0.042), 0.54 +/- 0.07 (P = 0.043), and 0.52 +/- 0.09 (P = 0.043), respectively. The specificity of CBCT for the detection and diagnosis of VRFs did not differ significantly (P = 0.50). Conclusion Cone-beam computed tomography was helpful in VRF diagnosis even when it was not possible to visualize the fracture line.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 50 条
  • [21] Diagnosis of alveolar and root fractures: an in vitro study comparing CBCT imaging with periapical radiographs
    Kobayashi-Velasco, Solange
    Sales Salineiro, Fernanda Cristina
    Gialain, Ivan Onone
    Paraiso Cavalcanti, Marcelo Gusmao
    JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (02) : 227 - 233
  • [22] Diagnosis of Vertical Root Fractures in Restored Endodontically Treated Teeth: A Time-dependent Retrospective Cohort Study
    PradeepKumar, Angambakkam Rajasekaran
    Shemesh, Hagay
    Jothilatha, Sundaramurthy
    Vijayabharathi, Rangarajan
    Jayalakshmi, Somasundaram
    Kishen, Anil
    JOURNAL OF ENDODONTICS, 2016, 42 (08) : 1175 - 1180
  • [23] Diagnosis of root fractures using cone-beam computed tomography: difference of vertical and horizontal root fracture
    Fumi Mizuhashi
    Ichiro Ogura
    Yoshihiro Sugawara
    Makoto Oohashi
    Ryo Mizuhashi
    Hisato Saegusa
    Oral Radiology, 2021, 37 : 305 - 310
  • [24] The 'Sharpen' filter improves the radiographic detection of vertical root fractures
    Nascimento, H. A. R.
    Ramos, A. C. A.
    Neves, F. S.
    de-Azevedo-Vaz, S. L.
    Freitas, D. Q.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (05) : 428 - 434
  • [25] Detection of artificially induced vertical root fractures of different widths by cone beam computed tomography invitro and invivo
    Makeeva, I. M.
    Byakova, S. F.
    Novozhilova, N. E.
    Adzhieva, E. K.
    Golubeva, G. I.
    Grachev, V. I.
    Kasatkina, I. V.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) : 980 - 989
  • [26] Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width
    Guo, X. L.
    Li, G.
    Zheng, J. Q.
    Ma, R. H.
    Liu, F. C.
    Yuan, F. S.
    Lyu, P. J.
    Guo, Y. J.
    Yin, S.
    INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) : 887 - 898
  • [27] Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures
    Caetano, Aline P. F.
    Sousa, Thiago O.
    Oliveira, Mariana R.
    Evanglista, Karine
    Bueno, Juliano M.
    Silva, Maria A. G.
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (03)
  • [28] The influence of metallic posts in the detection of vertical root fractures using different imaging examinations
    Jakobson, S. J. M.
    Westphalen, V. P. D.
    Silva Neto, U. X.
    Fariniuk, L. F.
    Schroeder, A. G. D.
    Carneiro, E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2014, 43 (01)
  • [29] Effect of fracture orientation on detection accuracy of vertical root fractures in non-endodontically treated teeth using cone beam computed tomography
    Xiao-Long Guo
    Gang Li
    Shuang Yin
    Ruo-Han Ma
    Yu-Jiao Guo
    Michael M. Bornstein
    Clinical Oral Investigations, 2019, 23 : 4433 - 4439
  • [30] Effect of fracture orientation on detection accuracy of vertical root fractures in non-endodontically treated teeth using cone beam computed tomography
    Guo, Xiao-Long
    Li, Gang
    Yin, Shuang
    Ma, Ruo-Han
    Guo, Yu-Jiao
    Bornstein, Michael M.
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (12) : 4433 - 4439