The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo

被引:29
作者
Byakova, S. F. [1 ]
Novozhilova, N. E. [1 ]
Makeeva, I. M. [1 ]
Grachev, V. I. [2 ]
Kasatkina, I. V. [3 ]
机构
[1] Sechenov Univ, IM Sechenov Moscow State Med Univ 1, Fed State Autonomous Educ Inst Higher Educ, Dept Therapeut Dent,Minist Hlth Russian Federat, Narodnogo Opolcheniya St 42-3-9, Moscow 123298, Russia
[2] 3D Lab, Independent Xray Diagnost Lab, Moscow, Russia
[3] RAS, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
关键词
cone-beam computed tomography; diagnosis; vertical root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; FILLED TEETH; VITRO; PREVALENCE; DENTIN; POSTS; AGE;
D O I
10.1111/iej.13114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results The average sensitivity of CBCT for the diagnosis of VRFs was 0.84 +/- 0.2. The accuracy and AUC values were 0.81 +/- 0.08 and 0.84 +/- 0.17, respectively. The sensitivity, accuracy and AUC values for the detection of VRFs were significantly lower: 0.17 +/- 0.24 (P = 0.042), 0.54 +/- 0.07 (P = 0.043), and 0.52 +/- 0.09 (P = 0.043), respectively. The specificity of CBCT for the detection and diagnosis of VRFs did not differ significantly (P = 0.50). Conclusion Cone-beam computed tomography was helpful in VRF diagnosis even when it was not possible to visualize the fracture line.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 50 条
[21]   Diagnosis and management of teeth with vertical root fractures [J].
Moule, AJ ;
Kahler, B .
AUSTRALIAN DENTAL JOURNAL, 1999, 44 (02) :75-87
[22]   Diagnosis of Vertical Root Fractures in Restored Endodontically Treated Teeth: A Time-dependent Retrospective Cohort Study [J].
PradeepKumar, Angambakkam Rajasekaran ;
Shemesh, Hagay ;
Jothilatha, Sundaramurthy ;
Vijayabharathi, Rangarajan ;
Jayalakshmi, Somasundaram ;
Kishen, Anil .
JOURNAL OF ENDODONTICS, 2016, 42 (08) :1175-1180
[23]   Diagnosis of alveolar and root fractures: an in vitro study comparing CBCT imaging with periapical radiographs [J].
Kobayashi-Velasco, Solange ;
Sales Salineiro, Fernanda Cristina ;
Gialain, Ivan Onone ;
Paraiso Cavalcanti, Marcelo Gusmao .
JOURNAL OF APPLIED ORAL SCIENCE, 2017, 25 (02) :227-233
[24]   Diagnosis of root fractures using cone-beam computed tomography: difference of vertical and horizontal root fracture [J].
Fumi Mizuhashi ;
Ichiro Ogura ;
Yoshihiro Sugawara ;
Makoto Oohashi ;
Ryo Mizuhashi ;
Hisato Saegusa .
Oral Radiology, 2021, 37 :305-310
[25]   Accuracy of three cone-beam CT devices and two software systems in the detection of vertical root fractures [J].
Caetano, Aline P. F. ;
Sousa, Thiago O. ;
Oliveira, Mariana R. ;
Evanglista, Karine ;
Bueno, Juliano M. ;
Silva, Maria A. G. .
DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (03)
[26]   The 'Sharpen' filter improves the radiographic detection of vertical root fractures [J].
Nascimento, H. A. R. ;
Ramos, A. C. A. ;
Neves, F. S. ;
de-Azevedo-Vaz, S. L. ;
Freitas, D. Q. .
INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (05) :428-434
[27]   Detection of artificially induced vertical root fractures of different widths by cone beam computed tomography invitro and invivo [J].
Makeeva, I. M. ;
Byakova, S. F. ;
Novozhilova, N. E. ;
Adzhieva, E. K. ;
Golubeva, G. I. ;
Grachev, V. I. ;
Kasatkina, I. V. .
INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (10) :980-989
[28]   Accuracy of detecting vertical root fractures in non-root filled teeth using cone beam computed tomography: effect of voxel size and fracture width [J].
Guo, X. L. ;
Li, G. ;
Zheng, J. Q. ;
Ma, R. H. ;
Liu, F. C. ;
Yuan, F. S. ;
Lyu, P. J. ;
Guo, Y. J. ;
Yin, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2019, 52 (06) :887-898
[29]   Effect of fracture orientation on detection accuracy of vertical root fractures in non-endodontically treated teeth using cone beam computed tomography [J].
Xiao-Long Guo ;
Gang Li ;
Shuang Yin ;
Ruo-Han Ma ;
Yu-Jiao Guo ;
Michael M. Bornstein .
Clinical Oral Investigations, 2019, 23 :4433-4439
[30]   Effect of fracture orientation on detection accuracy of vertical root fractures in non-endodontically treated teeth using cone beam computed tomography [J].
Guo, Xiao-Long ;
Li, Gang ;
Yin, Shuang ;
Ma, Ruo-Han ;
Guo, Yu-Jiao ;
Bornstein, Michael M. .