The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo

被引:29
作者
Byakova, S. F. [1 ]
Novozhilova, N. E. [1 ]
Makeeva, I. M. [1 ]
Grachev, V. I. [2 ]
Kasatkina, I. V. [3 ]
机构
[1] Sechenov Univ, IM Sechenov Moscow State Med Univ 1, Fed State Autonomous Educ Inst Higher Educ, Dept Therapeut Dent,Minist Hlth Russian Federat, Narodnogo Opolcheniya St 42-3-9, Moscow 123298, Russia
[2] 3D Lab, Independent Xray Diagnost Lab, Moscow, Russia
[3] RAS, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
关键词
cone-beam computed tomography; diagnosis; vertical root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; FILLED TEETH; VITRO; PREVALENCE; DENTIN; POSTS; AGE;
D O I
10.1111/iej.13114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results The average sensitivity of CBCT for the diagnosis of VRFs was 0.84 +/- 0.2. The accuracy and AUC values were 0.81 +/- 0.08 and 0.84 +/- 0.17, respectively. The sensitivity, accuracy and AUC values for the detection of VRFs were significantly lower: 0.17 +/- 0.24 (P = 0.042), 0.54 +/- 0.07 (P = 0.043), and 0.52 +/- 0.09 (P = 0.043), respectively. The specificity of CBCT for the detection and diagnosis of VRFs did not differ significantly (P = 0.50). Conclusion Cone-beam computed tomography was helpful in VRF diagnosis even when it was not possible to visualize the fracture line.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 42 条
[1]  
*AM AC FAM PHYS, 1997, AAFP POLICY ACTION, P1
[2]   A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth [J].
Brady, E. ;
Mannocci, F. ;
Brown, J. ;
Wilson, R. ;
Patel, S. .
INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (08) :735-746
[3]   Spatial resolution in CBCT machines for dental/maxillofacial applications-what do we know today? [J].
Bruellmann, D. ;
Schulze, R. K. W. .
DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (01)
[4]   Comparing the In Vivo Diagnostic Accuracy of Digital Periapical Radiography with Cone-beam Computed Tomography for the Detection of Vertical Root Fracture [J].
Chavda, Rajesh ;
Mannocci, Francesco ;
Andiappan, Manoharan ;
Patel, Shanon .
JOURNAL OF ENDODONTICS, 2014, 40 (10) :1524-1529
[5]   A demographic analysis of vertical root fractures [J].
Cohen, Stephen ;
Berman, Louis H. ;
Blanco, Lucia ;
Bakland, Leif ;
Kim, Jay S. .
JOURNAL OF ENDODONTICS, 2006, 32 (12) :1160-1163
[6]   Cone beam computed tomography for the diagnosis of vertical root fractures: a systematic review of the literature and meta-analysis [J].
Corbella, Stefano ;
Del Fabbro, Massimo ;
Tamse, Aviad ;
Rosen, Eyal ;
Tsesis, Igor ;
Taschieri, Silvio .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 118 (05) :593-602
[7]   Diagnosis of Mesiodistal Vertical Root Fractures in Teeth with Metal Posts: Influence of Applying Filters in Cone-beam Computed Tomography Images at Different Resolutions [J].
De Martin e Silva, Debora ;
Campos, Celso Neiva ;
Pires Carvalho, Antonio Carlos ;
Devito, Karina Lopes .
JOURNAL OF ENDODONTICS, 2018, 44 (03) :470-474
[8]   Detection of vertical root fractures in endodontically treated teeth in the absence and in the presence of metal post by cone-beam computed tomography [J].
de Menezes, Rebeca Ferraz ;
de Araujo, Natalia Costa ;
Costa Santa Rosa, Joedy Maria ;
Macedo Carneiro, Vanda Sanderana ;
dos Santos Neto, Alexandrino Pereira ;
Costa, Vanio ;
Moreno, Lara Marques ;
Miranda, Jessica Meirinhos ;
de Albuquerque, Diana Santana ;
Albuquerque, Monica ;
dos Santos, Roberto Alves ;
Marquez de Martinez Gerbi, Marleny Elizabeth .
BMC ORAL HEALTH, 2016, 16
[9]   Detection of Vertical Root Fractures by Using Cone-beam Computed Tomography: A Clinical Study [J].
Edlund, Mitchell ;
Nair, Madhu K. ;
Nair, Umadevi P. .
JOURNAL OF ENDODONTICS, 2011, 37 (06) :768-772
[10]   Different Representations of Vertical Root Fractures Detected by Cone-Beam Volumetric Tomography: A Case Series Report [J].
Fayad, Mohamed I. ;
Ashkenaz, Paul J. ;
Johnson, Bradford R. .
JOURNAL OF ENDODONTICS, 2012, 38 (10) :1435-1442