The accuracy of CBCT for the detection and diagnosis of vertical root fractures in vivo

被引:28
|
作者
Byakova, S. F. [1 ]
Novozhilova, N. E. [1 ]
Makeeva, I. M. [1 ]
Grachev, V. I. [2 ]
Kasatkina, I. V. [3 ]
机构
[1] Sechenov Univ, IM Sechenov Moscow State Med Univ 1, Fed State Autonomous Educ Inst Higher Educ, Dept Therapeut Dent,Minist Hlth Russian Federat, Narodnogo Opolcheniya St 42-3-9, Moscow 123298, Russia
[2] 3D Lab, Independent Xray Diagnost Lab, Moscow, Russia
[3] RAS, AN Frumkin Inst Phys Chem & Electrochem, Moscow, Russia
关键词
cone-beam computed tomography; diagnosis; vertical root fracture; BEAM COMPUTED-TOMOGRAPHY; PERIAPICAL RADIOGRAPHY; FILLED TEETH; VITRO; PREVALENCE; DENTIN; POSTS; AGE;
D O I
10.1111/iej.13114
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To compare the in vivo accuracy of CBCT for the detection of fracture lines versus the diagnosis of vertical root fractures (VRFs) according to characteristic patterns of associated bone resorption. Methodology Eighty-eight patients with symptoms typical of VRFs in root filled teeth, who underwent a CBCT examination and later had the teeth extracted, were divided into two groups: the fracture group (n = 65) and the control group (n = 23). Five blinded observers assessed the CBCT images in two sessions. During the first session, they were asked to state the diagnosis according to the CBCT and clinical data. During the second session after 2 weeks, they assessed only axial slices and were asked to detect a fracture line. The mean CBCT specificity, sensitivity, accuracy values and area under the receiver operating characteristic (AUROC) curve were calculated and compared using the Wilcoxon signed-rank test. Results The average sensitivity of CBCT for the diagnosis of VRFs was 0.84 +/- 0.2. The accuracy and AUC values were 0.81 +/- 0.08 and 0.84 +/- 0.17, respectively. The sensitivity, accuracy and AUC values for the detection of VRFs were significantly lower: 0.17 +/- 0.24 (P = 0.042), 0.54 +/- 0.07 (P = 0.043), and 0.52 +/- 0.09 (P = 0.043), respectively. The specificity of CBCT for the detection and diagnosis of VRFs did not differ significantly (P = 0.50). Conclusion Cone-beam computed tomography was helpful in VRF diagnosis even when it was not possible to visualize the fracture line.
引用
收藏
页码:1255 / 1263
页数:9
相关论文
共 50 条
  • [1] The detection of vertical root fractures in root filled teeth with periapical radiographs and CBCT scans
    Patel, S.
    Brady, E.
    Wilson, R.
    Brown, J.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (12) : 1140 - 1152
  • [2] Accuracy of Digital Subtraction Radiography in the Detection of Vertical Root Fractures
    Queiroz, Polyane Mazucatto
    Ribeiro Nascimento, Helena Aguiar
    Jacome da Paz, Thais Diniz
    Anacleto, Felipe Nogueira
    Freitas, Deborah Queiroz
    JOURNAL OF ENDODONTICS, 2016, 42 (06) : 896 - 899
  • [3] Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study
    Lagos de Melo, Larissa Pereira
    Queiroz, Polyane Mazucatto
    Moreira-Souza, Larissa
    Nadaes, Mariana Rocha
    Santaella, Gustavo Machado
    Oliveira, Matheus Lima
    Freitas, Deborah Queiroz
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2023, 48 (02)
  • [4] Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts
    Bezerra, I. S. Q.
    Neves, F. S.
    Vasconcelos, T. V.
    Ambrosano, G. M. B.
    Freitas, D. Q.
    DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (06)
  • [5] Digital subtraction radiography in detection of vertical root fractures: accuracy evaluation for root canal filling, fracture orientation and width variables. An ex-vivo study
    Kapralos, Vasileios
    Koutroulis, Andreas
    Irinakis, Eleni
    Kouros, Pantelis
    Lyroudia, Kleoniki
    Pitas, Ioannis
    Mikrogeorgis, Georgios
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (10) : 3671 - 3681
  • [6] Influence of CBCT enhancement filters on diagnosis of vertical root fractures: a simulation study in endodontically treated teeth with and without intracanal posts
    Ferreira, L. M.
    Visconti, M. A. P. G.
    Nascimento, H. A.
    Dallemolle, R. R.
    Ambrosano, G. M.
    Freitas, D. Q.
    DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (05)
  • [7] Influence of the technical parameters of CBCT image acquisition on vertical root fracture diagnosis: a systematic review and meta-analysis
    de Lima, Kaique Leite
    Silva, Lorena Rosa
    de Paiva Prado, Thayse Bernardes
    Silva, Maria Alves Garcia
    de Freitas Silva, Brunno Santos
    Yamamoto-Silva, Fernanda Paula
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (2) : 433 - 474
  • [8] Impact of Fracture Line Width on Radiographic Diagnosis of Vertical Root Fractures: Analysis of the Generalised Estimating Equation Model
    de Lima, Kaique Leite
    Silva, Lorena Rosa
    Neto, Mozar Andrade Mota
    Cavalcanti, Marcelo Gusmao Paroiso
    Leles, Claudio Rodrigues
    Silva, Maria Alves Garcia Santos
    Estrela, Carlos
    Silva, Brunno Santos de Freitas
    Yamamoto-Silva, Femanda P.
    CHINESE JOURNAL OF DENTAL RESEARCH, 2022, 25 (03) : 197 - 204
  • [9] Influence of a Metal Artifact Reduction Filter on the Diagnostic Accuracy of Complete and Incomplete Vertical Root Fractures
    Dias-Junior, Luiz Carlos de Lima
    Correa, Marcio
    Porto, Olavo Cesar Lyra
    Estrela, Carlos
    Teixeira, Cleonice da Silveira
    Garcia, Lucas da Fonseca Roberti
    Bortoluzzi, Eduardo Antunes
    JOURNAL OF ENDODONTICS, 2023, 49 (10) : 1352 - 1361
  • [10] Diagnosis of root fractures using cone-beam computed tomography: difference of vertical and horizontal root fracture
    Mizuhashi, Fumi
    Ogura, Ichiro
    Sugawara, Yoshihiro
    Oohashi, Makoto
    Mizuhashi, Ryo
    Saegusa, Hisato
    ORAL RADIOLOGY, 2021, 37 (02) : 305 - 310