Suture-guided sulcus implantation of a single-piece foldable acrylic intraocular lens after posterior capsule rupture

被引:2
作者
Sethi, Harinder Singh
Naik, Mayuresh P. [1 ]
机构
[1] Safdarjang Hosp, Room 430 Eye OPD,4th Floor OPD Bldg,Ring Rd, New Delhi 110029, India
关键词
CATARACT-SURGERY; PHACOEMULSIFICATION;
D O I
10.1016/j.jcrs.2017.02.001
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We describe a technique for suture-guided sulcus implantation of a foldable acrylic posterior chamber IOL (PC IOL). A 100 monofilament nylon suture is used to control insertion of the PC IOL over the ciliary sulcus and enable safe retrieval if the PC IOL drops during insertion, stabilization, or centration. In this technique, the 10-0 monofilament nylon suture acts as a guy rope to hold onto the PC IOL, enabling the surgeon to inject the IOL into the sulcus, unfold it in the iris plane, dial it in the appropriate meridian, and stabilize it. (C) 2017 ASCRS and ESCRS
引用
收藏
页码:309 / 311
页数:3
相关论文
共 37 条
[21]   Incidence of posterior capsule opacification following the implantation of a foldable hydrophilic acrylic intraocular lens: a 4 year follow-up study [J].
Jorge, Priscilla de Almeida ;
Jorge, Delano ;
Ventura, Camila Vieira ;
Ventura, Bruna Vieira ;
Lira, Wagner ;
Ventura, Marcelo Carvalho ;
Santhiago, Marcony Rodrigues ;
Kara-Junior, Newton .
ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (04) :222-224
[22]   Two single-piece acrylic intraocular lens choices and their effect on patient-reported driving habits [J].
Wright, Alex J. ;
Singh, Malkit K. ;
Henriksen, Bradley S. ;
McFadden, Molly ;
Olson, Randall J. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (02) :239-245
[23]   Rotational Stability of a Single-Piece Hydrophobic Acrylic Intraocular Lens During Removal of Ophthalmic Viscosurgical Devices [J].
Hyon, Joon Young ;
Yeo, Hwan Eok .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (02) :253-257
[24]   Management of sulcus-fixated single-piece intraocular lens-induced pigmentary glaucoma with 3-piece IOL exchange [J].
Rabie, Hossein Mohammad ;
Esfandiari, Hamed ;
Rikhtegar, Mohammad Hassan ;
Hekmat, Vahid .
INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (01) :145-150
[25]   Intermediate term follow-up after a single-piece-acrylic intraocular lens implantation in the ciliary sulcus- a cross-sectional study [J].
Bar-Sela, Shai M. ;
Fleissig, Efrat .
BMC OPHTHALMOLOGY, 2013, 13
[26]   Bilateral Implantation of a Single-Piece Bifocal Diffractive Intraocular Lens in Presbyopic Patients: A Prospective Case Series [J].
Chang, John S. M. .
ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (01) :12-21
[27]   A Case of Pigment Dispersion Syndrome after Placement of Sulcus Intraocular Lens with 7-mm Optic Diameter after Posterior Capsule Rupture [J].
Nagata, Mayumi ;
Matsushima, Hiroyuki ;
Senoo, Tadashi .
CASE REPORTS IN OPHTHALMOLOGY, 2022, 13 (03) :1012-+
[28]   Visual function after monocular implantation of apodized diffractive multifocal or single-piece monofocal intraocular lens Randomized prospective comparison [J].
Zhao, Guiqiu ;
Zhang, Jing ;
Zhou, Yang ;
Hu, Liting ;
Che, Chengye ;
Jiang, Nan .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (02) :282-285
[29]   Rotational stability and capsular bag performance of a hydrophobic acrylic open-loop single-piece intraocular lens [J].
Ullrich, Marlies ;
Fisus, Andreea D. ;
Palkovits, Stefan ;
Hienert, Julius ;
Hirnschall, Nino ;
Findl, Oliver .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (06) :1899-1908
[30]   Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification [J].
Iwase, Takeshi ;
Nishi, Yutarou ;
Oveson, Brian C. ;
Jo, Young-Joon .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) :1060-1068