AN LC-MS ASSAY WITH ISOCRATIC SEPARATION AND ON-LINE SOLID PHASE EXTRACTION TO IMPROVE THE ROUTINE THERAPEUTIC DRUG MONITORING OF BUSULFAN IN PLASMA

被引:4
作者
Ialongo, Cristiano [1 ,2 ]
Mozzi, Alessia Francesca [2 ]
Bernardini, Sergio [2 ,3 ]
机构
[1] Sapienza Univ Rome, Dept Physiol & Pharmacol, Rome, Italy
[2] Tor Vergata Univ Hosp Rome, Dept Lab Med, Rome, Italy
[3] Univ Roma Tor Vergata, Dept Expt Med & Surg, Rome, Italy
关键词
busulfan; drug monitoring; tandem-mass spectrometry; solid phase extraction; hematopoietic stem cell transplantation; TANDEM-MASS-SPECTROMETRY; STEM-CELL TRANSPLANTATION; INTRAVENOUS BUSULFAN; QUANTIFICATION; MS/MS; CHILDREN; PHARMACOKINETICS;
D O I
10.1515/jomb-2016-0031
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Background: Busulfan (Bu) requires therapeutic drug monitoring (TDM) in subjects undergoing a conditioning regimen for hematopoietic stem cell transplantation (HSCT). To speed up the procedure and increase reproducibility, we improved our routine LC-MS/MS assay using the on-line solid-phase extraction (SPE) of samples. Methods: A protein precipitation (PP) step was performed before the on-line SPE of Bu from 200 mu L of plasma spiked with octa-deuterated Bu (D8-Bu) as the internal standard. Bias was assessed with respect to our routine LC-MS/MS Bu assay with off-line extraction using the Passing-Bablok robust regression. Root cause of bias for individual samples was assessed by analyzing the regression residuals. Results: The method was linear in the range 37.75-2,416 ng/mL (r2> 0.999), with 19.74 ng/mL LLOQ and 10.5% CV at 20 ng/mL. Precision and accuracy were both within +/- 5%, and neither appreciable matrix nor carryover effects were observed. The Passing-Bablok regression analysis returned a 0.99 slope (95% CI: 0.97 to 1.01) and -6.82 intercept (95% CI: -15.23 to 3.53). Residuals analysis against the 2.5th-97.5th percentiles range showed four samples with significant bias individually. Conclusions: The method presented can be successfully employed for the routine analysis of Bu in plasmatic samples, and can replace the LC-MS/MS method with off-line extraction without any statistically significant overall bias. In this regard, samples with individual significant bias were reasonably produced by preanalytical issues which had no relation with the conversion to the on-line SPE extraction.
引用
收藏
页码:113 / 121
页数:9
相关论文
共 32 条
[1]   Therapeutic drug monitoring and LC-MS/MS [J].
Adaway, Joanne E. ;
Keevil, Brian G. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 883 :33-49
[2]   Acute safety and pharmacokinetics of intravenous busulfan when used with oval busulfan and cyclophosphamide as pretransplantation conditioning therapy: A phase I study [J].
Andersson, BS ;
Madden, T ;
Tran, HT ;
Hu, WW ;
Blume, KG ;
Chow, DSL ;
Champlin, RE ;
Vaughan, WP .
BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2000, 6 (5A) :548-554
[3]   Busulfan systemic exposure relative to regimen-related toxicity and acute graft-versus-host disease: Defining a therapeutic window for IV BuCy2 in chronic myelogenous leukemia [J].
Andersson, BS ;
Thall, PF ;
Madden, T ;
Couriel, D ;
Wang, XM ;
Tran, HT ;
Anderlini, P ;
de Lima, M ;
Gajewski, J ;
Champlin, RE .
BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2002, 8 (09) :477-485
[4]   Ion suppression in mass spectrometry [J].
Annesley, TM .
CLINICAL CHEMISTRY, 2003, 49 (07) :1041-1044
[5]   A simplified method for busulfan monitoring using dried blood spot in combination with liquid chromatography/tandem mass spectrometry [J].
Ansari, Marc ;
Uppugunduri, Chakradhara Rao S. ;
Deglon, Julien ;
Theoret, Yves ;
Versace, Francois ;
Gumy-Pause, Fabienne ;
Ozsahin, Hulya ;
Dayer, Pierre ;
Desmules, Jules ;
Daali, Youssef .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (12) :1437-1446
[6]  
Balasubramanian P, 2001, CLIN CHEM, V47, P766
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   A fast and simple assay for busulfan in serum or plasma by liquid chromatography-tandem mass spectrometry using turbulent flow online extraction technology [J].
Bunch, Dustin R. ;
Heideloff, Courtney ;
Ritchie, James C. ;
Wang, Sihe .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (31) :3255-3258
[9]   On-line Coupling of Solid-Phase Extraction to Liquid Chromatography-A Review [J].
Chen, Ligang ;
Wang, Hui ;
Zeng, Qinglei ;
Xu, Yang ;
Sun, Lei ;
Xu, Haoyan ;
Ding, Lan .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (08) :614-623
[10]   Determination of Busulfan in Human Plasma Using an ELISA Format [J].
Courtney, Jodi B. ;
Harney, Rebecca ;
Li, Yunying ;
Lundell, Gregory ;
McMillin, Gwendolyn A. ;
Agarwal, Geeta ;
Juenke, JoEtta M. ;
Mathew, Anu ;
Gonzalez-Espinoza, Rita ;
Fleisher, Martin ;
Salamone, Salvatore J. .
THERAPEUTIC DRUG MONITORING, 2009, 31 (04) :489-494