Remote Atmospheric Pressure Infrared Matrix-Assisted Laser Desorption-Ionization Mass Spectrometry (Remote IR-MALDI MS) of Proteins

被引:9
作者
Fatou, Benoit [1 ,2 ]
Ziskind, Michael [2 ]
Saudemont, Philippe [1 ,3 ]
Quanico, Jusal [1 ,2 ]
Focsa, Cristian [2 ]
Salzet, Michel [1 ]
Fournier, Isabelle [1 ]
机构
[1] Univ Lille, INSERM, U1192, Lab Prote Reponse Inflammatoire & Spectrometrie M, F-59000 Lille, France
[2] Univ Lille, CNRS, UMR 8523, PhLAM, F-59000 Lille, France
[3] SATT Nord, Immeuble Cent Gare, 4e Etage,25 Ave Charles St Venant, F-59800 Lille, France
关键词
UV-MALDI; CHARGED PEPTIDE; ION EXTRACTION; DESORPTION/IONIZATION; IDENTIFICATION; BIOMOLECULES; CLUSTERS; YIELDS;
D O I
10.1074/mcp.TIR117.000582
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Remote Infrared Matrix-Assisted Laser Desorption/Ionization (Remote IR-MALDI) system using tissue endogenous water as matrix was shown to enable in vivo real-time mass spectrometry analysis with minimal invasiveness. Initially the system was used to detect metabolites and lipids. Here, we demonstrate its capability to detect and analyze peptides and proteins. Very interestingly, the corresponding mass spectra show ESI-like charge state distribution, opening many applications for structural elucidation to be performed in real-time by Top-Down strategy. The charge states show no dependence toward laser wavelength or length of the transfer tube. Indeed, remote analysis can be performed 5 m away from the mass spectrometer without modification of spectra. On the contrary, addition of glycerol to water shift the charge state distributions toward even higher charge states. The desorption/ionization process is very soft, allowing to maintain protein conformation as in ESI. Observation of proteins and similar spectral features on tissue, when protein standards are deposited on raw tissue pieces, could potentially open the way to their direct analysis from biological samples. This also brings interesting features that could contribute to the understanding of IR MALDI ionization mechanism.
引用
收藏
页码:1637 / 1649
页数:13
相关论文
共 41 条
[1]   Ambient mass spectrometry: bringing MS into the "real world" [J].
Alberici, Rosana M. ;
Simas, Rosineide C. ;
Sanvido, Gustavo B. ;
Romao, Wanderson ;
Lalli, Priscila M. ;
Benassi, Mario ;
Cunha, Ildenize B. S. ;
Eberlin, Marcos N. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (01) :265-294
[2]   In Vivo Endoscopic Tissue Identification by Rapid Evaporative Ionization Mass Spectrometry (REIMS) [J].
Balog, Julia ;
Kumar, Sacheen ;
Alexander, James ;
Golf, Ottmar ;
Huang, Juzheng ;
Wiggins, Tom ;
Abbassi-Ghadi, Nima ;
Enyedi, Attila ;
Kacska, Sandor ;
Kinross, James ;
Hanna, George B. ;
Nicholson, Jeremy K. ;
Takats, Zoltan .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2015, 54 (38) :11059-11062
[3]   Intraoperative Tissue Identification Using Rapid Evaporative Ionization Mass Spectrometry [J].
Balog, Julia ;
Sasi-Szabo, Laszlo ;
Kinross, James ;
Lewis, Matthew R. ;
Muirhead, Laura J. ;
Veselkov, Kirill ;
Mirnezami, Reza ;
Dezso, Balazs ;
Damjanovich, Laszlo ;
Darzi, Ara ;
Nicholson, Jeremy K. ;
Takats, Zoltan .
SCIENCE TRANSLATIONAL MEDICINE, 2013, 5 (194)
[4]   Identification of Biological Tissues by Rapid Evaporative Ionization Mass Spectrometry [J].
Balog, Julia ;
Szaniszlo, Tamas ;
Schaefer, Karl-Christian ;
Denes, Julia ;
Lopata, Antal ;
Godorhazy, Lajos ;
Szalay, Daniel ;
Balogh, Lajos ;
Sasi-Szabo, Laszlo ;
Toth, Mikos ;
Takats, Zoltan .
ANALYTICAL CHEMISTRY, 2010, 82 (17) :7343-7350
[5]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[6]   Liquid AP-UV-MALDI Enables Stable Ion Yields of Multiply Charged Peptide and Protein Ions for Sensitive Analysis by Mass Spectrometry [J].
Cramer, Rainer ;
Pirkl, Alexander ;
Hillenkamp, Franz ;
Dreisewerd, Klaus .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (08) :2364-2367
[7]   Recent methodological advances in MALDI mass spectrometry [J].
Dreisewerd, Klaus .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (9-10) :2261-2278
[8]   In vivo Real-Time Mass Spectrometry for Guided Surgery Application [J].
Fatou, Benoit ;
Saudemont, Philippe ;
Leblanc, Eric ;
Vinatier, Denis ;
Mesdag, Violette ;
Wisztorski, Maxence ;
Focsa, Cristian ;
Salzet, Michel ;
Ziskind, Michael ;
Fournier, Isabelle .
SCIENTIFIC REPORTS, 2016, 6
[9]   Substrate-Mediated Laser Ablation under Ambient Conditions for Spatially-Resolved Tissue Proteomics [J].
Fatou, Benoit ;
Wisztorski, Maxence ;
Focsa, Cristian ;
Salzet, Michel ;
Ziskind, Michael ;
Fournier, Isabelle .
SCIENTIFIC REPORTS, 2015, 5
[10]   Ambient Ionization Mass Spectrometry for Point-of-Care Diagnostics and Other Clinical Measurements [J].
Ferreira, Christina R. ;
Yanne, Karen E. ;
Jarmusch, Alan K. ;
Pirro, Valentina ;
Ouyang, Zheng ;
Cooks, R. Graham .
CLINICAL CHEMISTRY, 2016, 62 (01) :99-110