Evaluation of tumor measurements in oncology: Use of film-based and electronic techniques

被引:82
作者
Schwartz, LH
Ginsberg, MS
DeCorato, D
Rothenberg, LN
Einstein, S
Kijewski, P
Panicek, DM
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Cornell Univ, Weill Med Coll, New York, NY USA
[4] Bioimaging Technol, W Trenton, NJ USA
关键词
D O I
10.1200/JCO.2000.18.10.2179
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To evaluate the variability in bidimensional computed tomography (CT) measurements obtained of actual tumors and of tumor phantoms by use of three measurement techniques: hand-held calipers on film, electronic calipers on a workstation, and an autocontour technique on a workstation. Materials and Methods: Three radiologists measured 45 actual tumors (in the lung, liver, and lymph nodes) on CT images, using each of the three techniques. Bidimensional measurements were recorded, and their cross-products calculated. The coefficient of variation was calculated to assess interobserver variability. CT images of 48 phantoms were measured by three radiologists with each of the techniques, In addition to the coefficient of variation, the differences between the cross-product measurements of tumor phantoms themselves and the measurements obtained with each of the techniques were calculated. Results: The differences between the coefficients of variation were statistically significantly different for the autocontour technique, compared with the other techniques, both for actual tumors and for tumor phantoms, There was no statistically significant difference in the coefficient of variation between measurements obtained with hand-held calipers and electronic calipers. The cross-products for tumor phantoms were 12% less than the actual cross-product when calipers on film were used, 11% less using electronic calipers, and 1% greater using the autocontour technique. Conclusion: Tumor size is obtained more accurately and consistently between readers using an automated autocontour technique than between those using handheld or electronic calipers. This finding has substantial implications for monitoring tumor therapy in an individual patient, as well as for evaluating the effectiveness of new therapies under development. J Clin Oncol 18:2179-2184. (C) 2000 by American Society of Clinical Oncology.
引用
收藏
页码:2179 / 2184
页数:6
相关论文
共 21 条
  • [1] Integrated multimedia timeline of medical images and data for thoracic oncology patients
    Aberle, DR
    Dionisio, JDN
    McNittGray, MF
    Taira, RK
    Cardenas, AF
    Goldin, JG
    Brown, K
    Figlin, RA
    Chu, WW
    [J]. RADIOGRAPHICS, 1996, 16 (03) : 669 - 681
  • [2] Evaluation of manual vs semi-automated delineation of liver lesions on CT images
    Bellon, E
    Feron, M
    Maes, F
    VanHoe, L
    Delaere, D
    Haven, F
    Sunaert, S
    Baert, AL
    Marchal, G
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (03) : 432 - 438
  • [3] Bui AAT, 1998, J AM MED INFORM ASSN, P165
  • [4] Chaney, 1992, Semin Radiat Oncol, V2, P215, DOI 10.1016/1053-4296(92)90019-H
  • [5] MEASURING MASSES ON CROSS-SECTIONAL IMAGES
    FORNAGE, BD
    [J]. RADIOLOGY, 1993, 187 (01) : 289 - 289
  • [6] Gurland J, 1966, Cancer Chemother Rep, V50, P119
  • [7] The impact of 2D versus 3D quantitation of tumor bulk determination on current methods of assessing response to treatment
    Hopper, KD
    Kasales, CJ
    Eggli, KD
    TenHave, TR
    Belman, NM
    Potok, PS
    VanSlyke, MA
    Olt, GJ
    Close, P
    Lipton, A
    Harvey, HA
    Hartzel, JS
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1996, 20 (06) : 930 - 937
  • [8] Analysis of interobserver and intraobserver variability in CT tumor measurements
    Hopper, KD
    Kasales, CJ
    VanSlyke, MA
    Schwartz, TA
    TenHave, TR
    Jozefiak, JA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (04) : 851 - 854
  • [9] LAVIN PT, 1980, CANCER, V46, P1286, DOI 10.1002/1097-0142(19800901)46:5<1286::AID-CNCR2820460533>3.0.CO
  • [10] 2-F