Support vector machines improve the accuracy of evaluation for the performance of laparoscopic training tasks

被引:28
作者
Allen, Brian [1 ]
Nistor, Vasile [2 ]
Dutson, Erik [3 ]
Carman, Greg [2 ]
Lewis, Catherine [3 ]
Faloutsos, Petros [1 ]
机构
[1] Univ Calif Los Angeles, Dept Comp Sci, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Dept Mech Engn, Los Angeles, CA 90024 USA
[3] Univ Calif Los Angeles, Dept Surg, Los Angeles, CA 90024 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2010年 / 24卷 / 01期
关键词
Minimally invasive surgery; Motion analysis; Objective evaluation; Support vector machines; Training; SKILLS; SURGERY; PROGRAM; CELTS;
D O I
10.1007/s00464-009-0556-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Despite technological advances in the tracking of surgical motions, automatic evaluation of laparoscopic skills remains remote. A new method is proposed that combines multiple discrete motion analysis metrics. This new method is compared with previously proposed metric combination methods and shown to provide greater ability for classifying novice and expert surgeons. Methods For this study, 30 participants (four experts and 26 novices) performed 696 trials of three training tasks: peg transfer, pass rope, and cap needle. Instrument motions were recorded and reduced to four metrics. Three methods of combining metrics into a prediction of surgical competency (summed-ratios, z-score normalization, and support vector machine [SVM]) were compared. The comparison was based on the area under the receiver operating characteristic curve (AUC) and the predictive accuracy with a previously unseen validation data set. Results For all three tasks, the SVM method was superior in terms of both AUC and predictive accuracy with the validation set. The SVM method resulted in AUCs of 0.968, 0.952, and 0.970 for the three tasks compared respectively with 0.958, 0.899, and 0.884 for the next best method (weighted z-normalization). The SVM method correctly predicted 93.7, 91.3, and 90.0% of the subjects' competencies, whereas the weighted z-normalization respectively predicted 86.6, 79.3, and 75.7% accurately (p < 0.002). Conclusions The findings show that an SVM-based analysis provides more accurate predictions of competency at laparoscopic training tasks than previous analysis techniques. An SVM approach to competency evaluation should be considered for computerized laparoscopic performance evaluation systems.
引用
收藏
页码:170 / 178
页数:9
相关论文
共 18 条
[1]   A valid method of laparoscopic simulation training and competence assessment [J].
Adrales, GL ;
Park, AE ;
Chu, UB ;
Witzke, DB ;
Donnelly, MB ;
Hoskins, JD ;
Mastrangelo, MJ ;
Gandsas, A .
JOURNAL OF SURGICAL RESEARCH, 2003, 114 (02) :156-162
[2]   Laparoscopic skills training and assessment [J].
Aggarwal, R ;
Moorthy, K ;
Darzi, A .
BRITISH JOURNAL OF SURGERY, 2004, 91 (12) :1549-1558
[3]   An evidence-based virtual reality training program for novice laparoscopic surgeons [J].
Aggarwal, Rajesh ;
Grantcharov, Teodor P. ;
Eriksen, Jens R. ;
Blirup, Dorthe ;
Kristiansen, Viggo B. ;
Funch-Jensen, Peter ;
Darzi, Ara .
ANNALS OF SURGERY, 2006, 244 (02) :310-314
[4]   LIBSVM: A Library for Support Vector Machines [J].
Chang, Chih-Chung ;
Lin, Chih-Jen .
ACM TRANSACTIONS ON INTELLIGENT SYSTEMS AND TECHNOLOGY, 2011, 2 (03)
[5]   Retracting and seeking movements during laparoscopic goal-oriented movements. Is the shortest path length optimal? [J].
Chmarra, Magdalena K. ;
Jansen, Frank Willem ;
Grimbergen, Cornelis A. ;
Dankelman, Jenny .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (04) :943-949
[6]  
Donias HW, 2002, AM SURGEON, V68, P177
[7]  
Fraser SA, 2003, SURG ENDOSC, V17, P964, DOI 10.1007/s00464-002-8828-4
[8]   Manual vs robotically assisted laparoscopic surgery in the performance of basic manipulation and suturing tasks [J].
Garcia-Ruiz, A ;
Gagner, M ;
Miller, JH ;
Steiner, CP ;
Hahn, JF .
ARCHIVES OF SURGERY, 1998, 133 (09) :957-961
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   Construct and face validity of MIST-VR, Endotower, and CELTS - Are we ready for skills assessment using simulators? [J].
Maithel, S ;
Sierra, R ;
Korndorffer, J ;
Neumann, P ;
Dawson, S ;
Callery, M ;
Jones, D ;
Scott, D .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2006, 20 (01) :104-112