High-resolution myocardial perfusion iImaging in mice with high-frequency echocardiographic detection of a depot contrast agent

被引:22
作者
Kaufmann, Beat A.
Lankford, Miles
Behm, Carolyn Z.
French, Brent A.
Klibanov, Alexander L.
Xu, Yaqin
Lindner, Jonathan R.
机构
[1] Oregon Hlth & Sci Univ, Div Cardiovasc, Portland, OR 97239 USA
[2] Univ Virginia, Charlottesville, VA USA
关键词
D O I
10.1016/j.echo.2006.08.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High-resolution methods for assessing myocardial perfusion in murine models of cardiovascular disease are needed. We hypothesized that regional hypoperfusion could be assessed with ultrahigh-frequency myocardial contrast echocardiography (MCE) and a novel strategy of depot contrast enhancement. MCE was performed with 30-MHz transthoracic imaging 10 seconds and 10 minutes after intravenous administration of microbubbles in control mice, and in mice after left anterior descending coronary artery ligation. MCE was also performed using size-segregated microbubbles. Microbubble behavior in the microcirculation was evaluated with intravital microscopy. In control mice anterior myocardial enhancement was robust at 10 seconds, but left ventricular cavity attenuation precluded evaluation of posterior segments. After 10 minutes, left ventricular cavity signal cleared but myocardial enhancement persisted, permitting analysis of all segments. The degree of enhancement at 10 min was related to microbubble size, implying retention of large microbubbles transiting pulmonary arteriovenous shunts. Intravital microscopy confirmed capillary lodging of large microbubbles. infarct size by delayed MCE correlated with fluorescent nanospheres (r = 0.94, P <.001). We conclude that complete assessment of regional myocardial perfusion in the mouse heart is possible with high-frequency MCE and a single intravenous contrast agent injection. This technique can be used for characterizing murine models of myocardial infarction and left ventricular remodeling.
引用
收藏
页码:136 / 143
页数:8
相关论文
共 19 条
[1]   MICROSPHERE AND DILUTION TECHNIQUES FOR THE DETERMINATION OF BLOOD FLOWS AND VOLUMES IN CONSCIOUS MICE [J].
BARBEE, RW ;
PERRY, BD ;
RE, RN ;
MURGO, JP .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (03) :R728-R733
[2]   ABSORPTION AND SCATTER OF ENCAPSULATED GAS FILLED MICROSPHERES - THEORETICAL CONSIDERATIONS AND SOME MEASUREMENTS [J].
DEJONG, N ;
HOFF, L ;
SKOTLAND, T ;
BOM, N .
ULTRASONICS, 1992, 30 (02) :95-103
[3]   Influence of microbubble surface charge on capillary transit and myocardial contrast enhancement [J].
Fisher, NG ;
Christiansen, JP ;
Klibanov, A ;
Taylor, RP ;
Kaul, S ;
Lindner, JR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (04) :811-819
[4]   ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR MASS AND SYSTOLIC FUNCTION IN MICE [J].
GARDIN, JM ;
SIRI, FM ;
KITSIS, RN ;
EDWARDS, JG ;
LEINWAND, LA .
CIRCULATION RESEARCH, 1995, 76 (05) :907-914
[5]   CAPILLARY DIAMETER IN RAT-HEART INSITU - RELATION TO ERYTHROCYTE DEFORMABILITY, O-2 TRANSPORT, AND TRANSMURAL O-2 GRADIENTS [J].
HENQUELL, L ;
LACELLE, PL ;
HONIG, CR .
MICROVASCULAR RESEARCH, 1976, 12 (03) :259-274
[6]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79
[7]   IN-VIVO ECHOCARDIOGRAPHIC DETECTION OF ENHANCED LEFT-VENTRICULAR FUNCTION IN GENE-TARGETED MICE WITH PHOSPHOLAMBAN DEFICIENCY [J].
HOIT, BD ;
HOURY, SF ;
KRANIAS, EG ;
BALL, N ;
WALSH, RA .
CIRCULATION RESEARCH, 1995, 77 (03) :632-637
[8]   Assessment of endogenous and therapeutic arteriogenesis by contrast ultrasound molecular Imaging of integrin expression [J].
Leong-Poi, H ;
Christiansen, J ;
Heppner, P ;
Lewis, CW ;
Klibanov, AL ;
Kaul, S ;
Lindner, JR .
CIRCULATION, 2005, 111 (24) :3248-3254
[9]   Ultrasound assessment of inflammation and renal tissue injury with microbubbles targeted to P-selectin [J].
Lindner, JR ;
Song, J ;
Christiansen, J ;
Klibanov, AL ;
Xu, F ;
Ley, K .
CIRCULATION, 2001, 104 (17) :2107-2112
[10]  
Lindner JR, 2000, CIRCULATION, V102, P531