Sensitivity studies of parameters for damage detection of plate-like structures using static and dynamic approaches

被引:105
作者
Yam, LH [1 ]
Li, YY [1 ]
Wong, WO [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Mech Engn, Kowloon, Hong Kong, Peoples R China
关键词
sensitivity analysis; damage detection; damage index; static and dynamic parameters; plate-like structures;
D O I
10.1016/S0141-0296(02)00094-9
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the sensitivities of static and dynamic parameters to damage occurring in plate-like structures are investigated systematically, and corresponding damage indices are proposed to analyse their identification capabilities. For static analyses, damage indices are formulated using the out-of-plane deflection, and its slope and curvature based on a finite element model; for dynamic analyses, two damage indices related to the curvature mode shape (CMS) and the strain frequency response function (SFRF) are proposed. Compared with the existing results, the effects of the numbers of the selected modes and defective areas on the CMS index and the influence of the "natural frequency shift" on the SFRF index are investigated. Numerical simulations and experimental tests are performed to verify the identification capability of the proposed indices, and guidance on selecting the proper parameters for damage detection is given. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1465 / 1475
页数:11
相关论文
共 14 条
[1]   Damage detection of plate-like structures [J].
Battipede, M ;
Ruotolo, R ;
Surace, C .
DAMAGE ASSESSMENT OF STRUCTURES, 2001, 204-2 :27-34
[2]   Application of the strain energy damage detection method to platelike structures [J].
Cornwell, P ;
Doebling, SW ;
Farrar, CR .
JOURNAL OF SOUND AND VIBRATION, 1999, 224 (02) :359-374
[3]  
DOEBLING SW, 1996, LA13070VA5 LOS AL NA
[4]   Sensitivity of parameter changes in structural damage detection [J].
Jenkins, CH ;
Kjerengtroen, L ;
Oestensen, H .
SHOCK AND VIBRATION, 1997, 4 (01) :27-37
[5]   Sensitivity analyses of sensor locations for vibration control and damage detection of thin-plate systems [J].
Li, YY ;
Yam, LH .
JOURNAL OF SOUND AND VIBRATION, 2001, 240 (04) :623-636
[6]   Sensitivity analysis of local/global modal parameters for identification of a crack in a beam [J].
Narayana, KL ;
Jebaraj, C .
JOURNAL OF SOUND AND VIBRATION, 1999, 228 (05) :977-994
[7]   Structural damage assessment with combined data of static and modal tests [J].
Oh, BH ;
Jung, BS .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (08) :956-965
[8]  
Rao JS., 1999, Dynamics of plates
[9]   Damage detection using the frequency-response-function curvature method [J].
Sampaio, RPC ;
Maia, NMM ;
Silva, JMM .
JOURNAL OF SOUND AND VIBRATION, 1999, 226 (05) :1029-1042
[10]  
*SPECTR DYN INC, 1994, 34050114 SPECTR DYN