Wide-detector CT combined iterative reconstruction in pediatric low-dose scan of the paranasal sinus

被引:4
作者
Kong, Que [1 ]
Lu, Fengqi [1 ]
Gao, Yu [1 ]
Qiao, Peng [1 ]
Shao, Min [1 ]
Xie, Min [1 ]
机构
[1] Nanjing Med Univ, Affiliated Wuxi Hosp 2, Dept Radiol, Wuxi, Jiangsu, Peoples R China
关键词
320-detector computed tomography (CT); wide-detector; iterative reconstruction; pediatric; paranasal sinus; low dose; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER; ANGIOGRAPHY; RISKS;
D O I
10.3233/XST-180487
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Computed tomography (CT) is considered a standard modality for imaging the paranasal sinus (PS), but increasingly radiation dose is of concern, especially in children. Objective: This study aims to investigate the feasibility of using a 320-detector CT scanner with a 16 cm wide-detector combined with iterative reconstruction (IR) algorithm to further reduce radiation dose when scanning the PS. METHODS: A total of 90 children who underwent CT of the PS were randomly allocated into three groups namely, (1) the experimental group using low-dose wide-detector scan (n = 30, 9 +/- 4 years); (2) low-dose helical group (n = 30, 9 +/- 4 years); and (3) pediatric conventional group (n = 30, 8 +/- 4 years). Statistical software SPSS 19.0 was used for one-way ANOVA analysis of the general data (age, BMI), image quality, and radiation dose. Multiple comparisons of data without homogeneity of variance were analyzed by Bonferroni test and Tamhane's test. RESULTS: All patients underwent successful CT examinations. No significant differences in the general data and image quality evaluation were detected between three groups (all P values > 0.05). CTDIvol and DLP were 2.87 mGy and 32.58 mGy.cm in the experimental group, 4.92 mGy and 70.84 mGy.cm in the low-dose helical group, and 9.95 mGy and 131.83 mGy.cm in the conventional group, respectively, which were significantly different among these three groups as indicated by multiple comparisons (all P values < 0.05). In the experimental group, the effective radiation dose was 0.07 mSv, which was reduced by 76% and 56% comparing to the conventional group and the low-dose helical group, respectively. CONCLUSIONS: The 320-detector CT scanner equipped with the wide-detector combined with IR can further reduce radiation dose, while maintaining good image quality comparing to the low-dose helical or pediatric modes.
引用
收藏
页码:731 / 738
页数:8
相关论文
共 25 条
  • [1] Bongarts G., 1999, 16262 EUR
  • [2] Blunt nasal trauma in children: a frequent diagnostic challenge
    Borner, Urs
    Anschuetz, Lukas
    Kaiser, Nadine
    Rieke, Alexander
    Dubach, Patrick
    Caversaccio, Marco
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (01) : 85 - 91
  • [3] Estimated risks of radiation-induced fatal cancer from pediatric CT
    Brenner, DJ
    Elliston, CD
    Hall, EJ
    Berdon, WE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) : 289 - 296
  • [4] Guidance on radiation dose limits for the lens of the eye: overview of the recommendations in NCRP Commentary No. 26
    Dauer, Lawrence T.
    Ainsbury, Elizabeth A.
    Dynlacht, Joseph
    Hoel, David
    Klein, Barbara E. K.
    Maye, Donald
    Prescott, Christina R.
    Thornton, Raymond H.
    Vano, Eliseo
    Woloschak, Gayle E.
    Flannery, Cynthia M.
    Goldstein, Lee E.
    Hamada, Nobuyuki
    Tran, Phung K.
    Grissom, Michael P.
    Blakely, Eleanor A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2017, 93 (10) : 1015 - 1023
  • [5] Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007
    de Gonzalez, Amy Berrington
    Mahesh, Mahadevappa
    Kim, Kwang-Pyo
    Bhargavan, Mythreyi
    Lewis, Rebecca
    Mettler, Fred
    Land, Charles
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) : 2071 - 2077
  • [6] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    Gay, F.
    Pavia, Y.
    Pierrat, N.
    Lasalle, S.
    Neuenschwander, S.
    Brisse, H. J.
    [J]. EUROPEAN RADIOLOGY, 2014, 24 (01) : 102 - 111
  • [7] Comparison of radiation dose estimates, image noise, and scan duration in pediatric body imaging for volumetric and helical modes on 320-detector CT and helical mode on 64-detector CT
    Johnston, Jennifer H.
    Podberesky, Daniel J.
    Yoshizumi, Terry T.
    Angel, Erin
    Toncheva, Greta
    Larson, David B.
    Egelhoff, John C.
    Anderson-Evans, Colin
    Nguyen, Giao B.
    Barelli, Alessandra
    Alsip, Christopher
    Salisbury, Shelia R.
    Frush, Donald P.
    [J]. PEDIATRIC RADIOLOGY, 2013, 43 (09) : 1117 - 1127
  • [8] Individual radiation exposure from computed tomography: a survey of paediatric practice in French university hospitals, 2010-2013
    Journy, Neige M. Y.
    Dreuil, Serge
    Boddaert, Nathalie
    Chateil, Jean-Francois
    Defez, Didier
    Ducou-le-Pointe, Hubert
    Garcier, Jean-Marc
    Guersen, Joel
    Geryes, Bouchra Habib
    Jahnen, Andreas
    Lee, Choonsik
    Payen-de-la-Garanderie, Jacqueline
    Pracros, Jean-Pierre
    Sirinelli, Dominique
    Thierry-chef, Isabelle
    Bernier, Marie-Odile
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (02) : 630 - 641
  • [9] Scan time and patient dose for thoracic imaging in neonates and small children using axial volumetric 320-detector row CT compared to helical 64-, 32-, and 16- detector row CT acquisitions
    Kroft L.J.M.
    Roelofs J.J.H.
    Geleijns J.
    [J]. Pediatric Radiology, 2010, 40 (3) : 294 - 300
  • [10] Application of 640-slice CT wide-detector volume scan in low-dose CT pulmonary angiography
    Lu, Fengqi
    Gao, Yu
    Kong, Que
    Qiao, Peng
    Shao, Min
    Xie, Min
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2019, 27 (02) : 197 - 205