Systematic review with meta-analysis: faecal occult blood tests show lower colorectal cancer detection rates in the proximal colon in colonoscopy-verified diagnostic studies

被引:54
作者
Hirai, H. W. [1 ,2 ,3 ]
Tsoi, K. K. F. [1 ,2 ]
Chan, J. Y. C. [1 ]
Wong, S. H. [3 ,4 ]
Ching, J. Y. L. [3 ]
Wong, M. C. S. [1 ,3 ]
Wu, J. C. Y. [3 ,4 ]
Chan, F. K. L. [3 ,4 ]
Sung, J. J. Y. [3 ,4 ]
Ng, S. C. [3 ,4 ]
机构
[1] Chinese Univ Hong Kong, Sch Publ Hlth & Primary Care, Shatin, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Stanley Ho Big Data Decis Analyt Res Ctr, Shatin, Hong Kong, Peoples R China
[3] Chinese Univ Hong Kong, Inst Digest Dis, Shatin, Hong Kong, Peoples R China
[4] Chinese Univ Hong Kong, Dept Med & Therapeut, LKS Inst Hlth Sci, State Key Lab Digest Dis, Shatin, Hong Kong, Peoples R China
关键词
IMMUNOCHEMICAL TESTS; SENSITIVITY; POPULATION; SPECIFICITY; ACCURACY;
D O I
10.1111/apt.13556
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BackgroundThe performance of faecal occult blood tests (FOBTs) to screen proximally located colorectal cancer (CRC) has produced inconsistent results. AimTo assess in a meta-analysis, the diagnostic accuracy of FOBTs for relative detection of CRC according to anatomical location of CRC. MethodsDiagnostic studies including both symptomatic and asymptomatic cohorts assessing performance of FOBTs for CRC were searched from MEDINE and EMBASE. Primary outcome was accuracy of FOBTs according to the anatomical location of CRC. Bivariate random-effects model was used. Subgroup analyses were performed to evaluate test performance of guaiac-based FOBT (gFOBT) and immunochemical-based FOBT (iFOBT). ResultsThirteen studies, with 17 cohorts, reporting performance of FOBT were included; a total of 26342 patients (mean age 58.9years; 58.1% male) underwent both colonoscopy and FOBT. Pooled sensitivity, specificity, positive likelihood ratio and negative likelihood ratio of FOBTs for CRC detection in the proximal colon were 71.2% (95% CI 61.3-79.4%), 93.6% (95% CI 90.7-95.7%), 11.1 (95% CI 7.8-15.8) and 0.3 (95% CI 0.2-0.4) respectively. Corresponding findings for CRC detection in distal colon were 80.1% (95% CI 70.9-87.0%), 93.6% (95% CI 90.7-95.7%), 12.6 (95% CI 8.8-18.1) and 0.2 (95% CI 0.1-0.3). The area-under-curve for FOBT detection for proximal and distal CRC were 90% vs. 94% (P=0.0143). Both gFOBT and iFOBT showed significantly lower sensitivity but comparable specificity for the detection of proximally located CRC compared with distal CRC. ConclusionFaecal occult blood tests, both guaiac- and immunochemical-based, show better diagnostic performance for the relative detection of colorectal cancer in the distal colon than in the proximal bowel.
引用
收藏
页码:755 / 764
页数:10
相关论文
共 46 条
  • [41] MEASURING THE ACCURACY OF DIAGNOSTIC SYSTEMS
    SWETS, JA
    [J]. SCIENCE, 1988, 240 (4857) : 1285 - 1293
  • [42] Well adjusted qualitative immunochemical faecal occult blood tests could be a promising alternative for inexpensive, high-quality colorectal cancer screening
    Tao, Sha
    Brenner, Hermann
    [J]. EUROPEAN JOURNAL OF CANCER PREVENTION, 2013, 22 (04) : 305 - 310
  • [43] CHEMICAL AND IMMUNOLOGICAL TESTING FOR FECAL OCCULT BLOOD - A COMPARISON OF 2 TESTS IN SYMPTOMATIC PATIENTS
    THOMAS, WM
    HARDCASTLE, JD
    JACKSON, J
    PYE, G
    [J]. BRITISH JOURNAL OF CANCER, 1992, 65 (04) : 618 - 620
  • [44] False negative fecal occult blood tests due to delayed sample return in colorectal cancer screening
    van Rossum, Leo G. M.
    van Rijn, Anne F.
    van Oijen, Martijn G. H.
    Fockens, Paul
    Laheij, Robert J. F.
    Verbeek, Andre L. M.
    Jansen, Jan B. M. J.
    Dekker, Evelien
    [J]. INTERNATIONAL JOURNAL OF CANCER, 2009, 125 (04) : 746 - 750
  • [45] QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies
    Whiting, Penny F.
    Rutjes, Anne W. S.
    Westwood, Marie E.
    Mallett, Susan
    Deeks, Jonathan J.
    Reitsma, Johannes B.
    Leeflang, Mariska M. G.
    Sterne, Jonathan A. C.
    Bossuyt, Patrick M. M.
    [J]. ANNALS OF INTERNAL MEDICINE, 2011, 155 (08) : 529 - U104
  • [46] Prescreening evaluation of a brush-based faecal immunochemical test for haemoglobin
    Young, GP
    St John, DJB
    Cole, SR
    Bielecki, BE
    Pizzey, C
    Sinatra, MA
    Polglase, AL
    Cadd, B
    Morcom, J