Tc-99m ethylene cysteinate dimer SPECT in the differential diagnosis of parkinsonism

被引:71
|
作者
Feigin, A
Antonini, A
Fukuda, M
De Notaris, R
Benti, R
Pezzoli, G
Mentis, MJ
Moeller, JR
Eidelberg, D
机构
[1] N Shore Univ Hosp, Ctr Neurosci, Manhasset, NY 11030 USA
[2] NYU, Sch Med, New York, NY USA
[3] Parkinsons Inst, Inst Clin Perfezionamento, Milan, Italy
[4] Columbia Univ Coll Phys & Surg, Dept Psychiat, New York, NY 10032 USA
关键词
ECD/SPECT; parkinsonism; differential diagnosis; network analysis;
D O I
10.1002/mds.10270
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Positron emission tomography (PET) and network analysis have been used to identify a reproducible pattern of regional metabolic covariation that is associated with idiopathic Parkinson's disease (PD). The activity of this PD-related pattern can be quantified in individual subjects and used to discriminate PD patients from atypical parkinsonians. Because PET is not commonly available, we sought to determine whether similar discrimination could be achieved using more routine single photon emission computed tomography (SPECT) perfusion methods. Twenty-three subjects with PD (age, 63 +/- 9 years), 22 subjects with multiple system atrophy (MSA; age, 64 +/- 7 years), and 20 age-matched healthy controls (age, 62 +/- 13 years) underwent SPECT imaging of regional cerebral perfusion with Tc-99m ethylene cysteinate dimer (ECD). Using network analysis, we determined whether a PD-related pattern existed in the SPECT data, and whether its expression discriminated PD from MSA patients. Additionally, we compared the accuracy of group discrimination achieved by this pattern with that of the PET-derived PD-related pattern applied to the SPECT data. Network analysis of the SPECT data identified a significant pattern characterized by relative increases in cerebellar, lentiform, and thalamic perfusion covarying with decrements in the frontal operculum and in the medial temporal cortex. Subject scores for this pattern discriminated PD patients from controls (P < 0.01) and from MSA patients (P < 0.03). Subject scores for the PET-derived PD-related pattern computed in the individual SPECT scans more accurately distinguished PD patients from controls (P < 0.005) and from MSA patients (P = 0.0002). A significant PD-related covariance pattern can be identified in SPECT perfusion data. Moreover, the disease related pattern identified previously with PET can be applied to individual SPECT perfusion scans to provide group discrimination between PD patients, healthy controls, and individuals with MSA. Because of significant individual subject overlap between groups, however, the clinical utility of this method in the differential diagnosis of Parkinsonism remains uncertain. (C) 2002 Movement Disorder Society.
引用
收藏
页码:1265 / 1270
页数:6
相关论文
共 50 条
  • [31] MEASUREMENT OF ABSOLUTE DIFFERENTIAL GFR USING TC-99M DMSA AND TC-99M DTPA
    POWERS, TA
    GROVE, RB
    BOWEN, RD
    PLUNKETT, JM
    KADIR, S
    ROLLO, FD
    PATTON, JA
    STONE, WJ
    INVESTIGATIVE RADIOLOGY, 1979, 14 (05) : 386 - 386
  • [32] Dual-tracer subtraction parathyroid SPECT using Tc-99m pertechnetate and Tc-99m MIBI
    Ekjeen, T.
    Chaichana, A.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [33] Comparison of parathyroid imaging with Tc-99m pertechnetate/sestamibi subtraction, dual-phase Tc-99m sestamibi, and Tc-99m sestamibi SPECT.
    Chen, CC
    Holder, LE
    Scovill, WA
    Tehan, AM
    Gann, DS
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 51 - 51
  • [34] Nodular regenerative hyperplasia of the liver SPECT evaluation with Tc-99m stannous colloid and Tc-99m neoglycoalbumin
    Yamamoto, W
    Shuke, N
    Saito, Y
    Usui, K
    Komura, K
    Ishizaki, A
    Ojima, H
    Aburano, T
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (10) : 806 - 808
  • [35] Analysis of Tc-99m TRODAY study in patients with Parkinsonism
    Lin, Yu-Wei
    Wang, Han-Cheng
    NEUROLOGY, 2018, 90
  • [36] Tc-99m DMSA and Tc-99m DTPA imaging in the diagnosis of crossed renal ectopia
    Büyükdereli, G
    Hazar, B
    Sargin, Ö
    Tuncer, R
    CLINICAL NUCLEAR MEDICINE, 2001, 26 (03) : 257 - 258
  • [37] Comparison of Tc-99m THY and Tc-99m MIBI scans for diagnosis of breast lesions
    Gutfilen, B
    da Fonseca, LMB
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2001, 20 (03) : 385 - 391
  • [38] NEUROPSYCHOLOGICAL TESTS AND [TC-99M]-HM PAO SPECT IN THE DIAGNOSIS OF ALZHEIMERS DEMENTIA
    VILLA, G
    CAPPA, A
    TAVOLOZZA, M
    GAINOTTI, G
    GIORDANO, A
    CALCAGNI, ML
    DEROSSI, G
    JOURNAL OF NEUROLOGY, 1995, 242 (06) : 359 - 366
  • [39] Tc-99m V-DMSA SPECT for the diagnosis of active Graves' ophthalmopathy
    Reyhan, M.
    Bakiner, O. S.
    Toygar, O.
    Sukan, A.
    Aydin, M.
    Yapar, A. F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S369 - S369
  • [40] Tc-99m HMPAO brain SPECT Imaging for the diagnosis of gray matter heterotopia
    Wince, WB
    Burt, R
    Schauwecker, DS
    Phillips, MD
    CLINICAL NUCLEAR MEDICINE, 2003, 28 (01) : 62 - 63