Preliminary Studies of Perovskite-Loaded Plastic Scintillator Prototypes for Radioactive Strontium Detection

被引:13
作者
Kang, Hara [1 ,2 ]
Min, Sujung [1 ,2 ]
Seo, Bumkyung [2 ]
Roh, Changhyun [2 ,3 ]
Hong, Sangbum [2 ]
Cheong, Jae Hak [1 ]
机构
[1] Kyung Hee Univ, Dept Nucl Engn, Yongin 17104, Gyeonggi Do, South Korea
[2] Korea Atom Energy Res Inst, Decommissioning Technol Res Div, Daejeon 34057, South Korea
[3] Univ Sci & Technol UST, Quantum Energy Chem Engn, 217 Gajeong Ro, Daejeon 34113, South Korea
基金
新加坡国家研究基金会;
关键词
sensor; nanomaterial; perovskite; plastic scintillator; beta-ray emitter; decommissioning; strontium detection;
D O I
10.3390/chemosensors9030053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Functional plastic scintillators have attracted much attention for their usefulness in on-site monitoring and detection in environments. In this study, we elucidated a highly reliable and functional plastic scintillator for detection of radioactive strontium, which means a potent perovskite-loaded polymeric scintillation material based on epoxy and 2,5-diphenyloxazole (PPO). Moreover, Monte Carlo N-Particle (MCNP) simulation was performed to optimize the thickness of a plastic scintillator for efficient strontium detection. A thickness of 2 mm was found to be the optimum thickness for strontium beta-ray detection. A newly developed plastic scintillator with 430 nm emission from perovskite loading could trigger scintillation enhancement employing potential indication of perovskite energy transfer into a photomultiplier (PMT) detector. Furthermore, the response to beta-ray emitter of Sr-90 was compared to commercial scintillator of BC-400 by exhibiting detection efficiency in the energy spectrum with a fabricated perovskite-loaded plastic scintillator. We believe that this suggested functional plastic scintillator could be employed as a radiation detector for strontium detection in a wide range of applications including decommissioning sites in nuclear facilities, nuclear security and monitoring, nonproliferation, and safeguards.
引用
收藏
页数:14
相关论文
共 53 条
  • [1] Microsecond-sustained lasing from colloidal quantum dot solids
    Adachi, Michael M.
    Fan, Fengjia
    Sellan, Daniel P.
    Hoogland, Sjoerd
    Voznyy, Oleksandr
    Houtepen, Arjan J.
    Parrish, Kevin D.
    Kanjanaboos, Pongsakorn
    Malen, Jonathan A.
    Sargent, Edward H.
    [J]. NATURE COMMUNICATIONS, 2015, 6
  • [2] Semiconductor clusters, nanocrystals, and quantum dots
    Alivisatos, AP
    [J]. SCIENCE, 1996, 271 (5251) : 933 - 937
  • [3] Pr3+-doped fluoro-oxide lithium glass as scintillator for nuclear fusion diagnostics
    Arikawa, Yasunobu
    Yamanoi, Kohei
    Nakazato, Tomoharu
    Estacio, Elmer Surat
    Shimizu, Toshihiko
    Sarukura, Nobuhiko
    Nakai, Mitsuo
    Norimatsu, Takayoshi
    Azechi, Hiroshi
    Murata, Takahiro
    Fujino, Shigeru
    Yoshida, Hideki
    Kamada, Kei
    Usuki, Yoshiyuki
    Suyama, Toshihisa
    Yoshikawa, Akira
    Sato, Nakahiro
    Kan, Hirofumi
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2009, 80 (11)
  • [4] A NEW RADIATION-HARD PLASTIC SCINTILLATOR
    BOWEN, M
    MAJEWSKI, S
    PETTEY, D
    WALKER, J
    WOJCIK, R
    ZORN, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 276 (1-2) : 391 - 393
  • [5] Fiber optically coupled radioluminescence detectors: A short review of key strengths and weaknesses of BCF-60 and Al2O3: C scintillating-material based systems in radiotherapy dosimetry applications.
    Buranurak, S.
    Andersen, C. E.
    [J]. INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016, 2017, 860
  • [6] Cerrito L., 2017, Radiation and Detectors: Introduction to the Physics of Radiation and Detection Devices, DOI [10.1007/978-3-319-53181-6, DOI 10.1007/978-3-319-53181-6]
  • [7] Evaluations of the Chemical Stability and Cytotoxicity of CuInS2 and CuInS2/ZnS Core/Shell Quantum Dots
    Chen, Chieh-Wei
    Wu, Dai-Ying
    Chan, Yung-Chieh
    Lin, Chun Che
    Chung, Po-Hsiang
    Hsiao, Michael
    Liu, Ru-Shi
    [J]. JOURNAL OF PHYSICAL CHEMISTRY C, 2015, 119 (05) : 2852 - 2860
  • [8] All-inorganic perovskite nanocrystal scintillators
    Chen, Qiushui
    Wu, Jing
    Ou, Xiangyu
    Huang, Bolong
    Almutlaq, Jawaher
    Zhumekenov, Ayan A.
    Guan, Xinwei
    Han, Sanyang
    Liang, Liangliang
    Yi, Zhigao
    Li, Juan
    Xie, Xiaoji
    Wang, Yu
    Li, Ying
    Fan, Dianyuan
    Teh, Daniel B. L.
    All, Angelo H.
    Mohammed, Omar F.
    Bakr, Osman M.
    Wu, Tom
    Bettinelli, Marco
    Yang, Huanghao
    Huang, Wei
    Liu, Xiaogang
    [J]. NATURE, 2018, 561 (7721) : 88 - 93
  • [9] Overcoming the electroluminescence efficiency limitations of perovskite light-emitting diodes
    Cho, Himchan
    Jeong, Su-Hun
    Park, Min-Ho
    Kim, Young-Hoon
    Wolf, Christoph
    Lee, Chang-Lyoul
    Heo, Jin Hyuck
    Sadhanala, Aditya
    Myoung, NoSoung
    Yoo, Seunghyup
    Im, Sang Hyuk
    Friend, Richard H.
    Lee, Tae-Woo
    [J]. SCIENCE, 2015, 350 (6265) : 1222 - 1225
  • [10] Pulse shape discrimination performance of a pixelated plastic scintillator (EJ-299-34) for a coded-aperture based dual particle imaging system
    Cieslak, M. J.
    Gamage, K. A. A.
    Glover, R.
    Taylor, C. J.
    [J]. JOURNAL OF INSTRUMENTATION, 2019, 14 (07)