Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics

被引:54
作者
Patrizi, Alfredo [1 ]
Pennestri, Ettore [1 ]
Valentini, Pier Paolo [1 ]
机构
[1] Univ Roma Tor Vergata, Dept Enterprise Engn, Via Politecn 1, I-00133 Rome, Italy
关键词
working posture; motion capture; Microsoft Kinect; marker-less; ergonomics; KINECT(TM) SENSOR; MICROSOFT KINECT; ACCURACY; POSTURES; VALIDITY; EXPOSURE;
D O I
10.1080/00140139.2015.1057238
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The paper deals with the comparison between a high-end marker-based acquisition system and a low-cost marker-less methodology for the assessment of the human posture during working tasks. The low-cost methodology is based on the use of a single Microsoft Kinect V1 device. The high-end acquisition system is the BTS SMART that requires the use of reflective markers to be placed on the subject's body. Three practical working activities involving object lifting and displacement have been investigated. The operational risk has been evaluated according to the lifting equation proposed by the American National Institute for Occupational Safety and Health. The results of the study show that the risk multipliers computed from the two acquisition methodologies are very close for all the analysed activities. In agreement to this outcome, the marker-less methodology based on the Microsoft Kinect V1 device seems very promising to promote the dissemination of computer-aided assessment of ergonomics while maintaining good accuracy and affordable costs. Practitioner's Summary: The study is motivated by the increasing interest for on-site working ergonomics assessment. We compared a low-cost marker-less methodology with a high-end marker-based system. We tested them on three different working tasks, assessing the working risk of lifting loads. The two methodologies showed comparable precision in all the investigations.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 23 条
[1]   Using Kinect™ sensor in observational methods for assessing postures at work [J].
Antonio Diego-Mas, Jose ;
Alcaide-Marzal, Jorge .
APPLIED ERGONOMICS, 2014, 45 (04) :976-985
[2]  
Berliner T., 2010, US Patent Application Publication, Patent No. [US 2010/0034457 A1, 20100034457]
[3]   Determination of the precision and accuracy of morphological measurements using the Kinect™ sensor: comparison with standard stereophotogrammetry [J].
Bonnechere, B. ;
Jansen, B. ;
Salvia, P. ;
Bouzahouene, H. ;
Sholukha, V. ;
Cornelis, J. ;
Rooze, M. ;
Jan, S. Van Sint .
ERGONOMICS, 2014, 57 (04) :622-631
[4]   Validity and reliability of the Kinect within functional assessment activities: Comparison with standard stereophotogrammetry [J].
Bonnechere, B. ;
Jansen, B. ;
Salvia, P. ;
Bouzahouene, H. ;
Omelina, L. ;
Moiseev, F. ;
Sholukha, V. ;
Cornelis, J. ;
Rooze, M. ;
Jan, S. Van Sint .
GAIT & POSTURE, 2014, 39 (01) :593-598
[5]   Validity of the Microsoft Kinect for assessment of postural control [J].
Clark, Ross A. ;
Pua, Yong-Hao ;
Fortin, Karine ;
Ritchie, Callan ;
Webster, Kate E. ;
Denehy, Linda ;
Bryant, Adam L. .
GAIT & POSTURE, 2012, 36 (03) :372-377
[7]   Accuracy of the Microsoft Kinect sensor for measuring movement in people with Parkinson's disease [J].
Galna, Brook ;
Barry, Gillian ;
Jackson, Dan ;
Mhiripiri, Dadirayi ;
Olivier, Patrick ;
Rochester, Lynn .
GAIT & POSTURE, 2014, 39 (04) :1062-1068
[8]  
Guerra-Filho G.B., 2005, J THEORETICAL APPL I, VRITA 12, P61
[9]  
ISO (International Organization for Standardization), 2003, 112282003 ISO
[10]   Assessment of work postures and movements using a video-based observation method and direct technical measurements [J].
Juul-Kristensen, B ;
Hansson, GÅ ;
Fallentin, N ;
Andersen, JH ;
Ekdahl, C .
APPLIED ERGONOMICS, 2001, 32 (05) :517-524