Thermal plume simulation of VRF air conditioners for cooling system in high-rise buildings: A case study in China

被引:0
作者
Zhang, Yin [1 ]
Zhang, Xiao [2 ]
Guo, Shurui [1 ]
Long, Enshen [1 ]
机构
[1] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Sichuan, Peoples R China
[2] HUAWEI Technol Ltd Co, Shenzhen 518116, Peoples R China
来源
JOURNAL OF ENGINEERING RESEARCH | 2019年 / 7卷 / 03期
基金
中国国家自然科学基金;
关键词
air conditioner; outdoor air; inlet temperature; thermal plume; simulation; FLOW; ENERGY; CFD; PERFORMANCE; MODEL;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Variable refrigerant flow (VRF) air conditioning system is widely used in commercial and residential buildings for space cooling and heating. However, some practical VRF systems used in high-rise buildings cannot work efficiently or even stop working because of the relatively high ambient temperature, caused by thermal plume effect of exhaust heat from outdoor units. In this paper, the thermal plume air flow of layer-based VRF systems is investigated through computational fluids dynamics (CFD) simulation. Moreover, an illustrative example in a 30-storey office building in China is conducted to optimize the layout of VRF outdoor units. Preliminary results show that the exhaust heat of outdoor units can cause ascending thermal plume flow, leading to higher inlet temperatures for VRF air conditioners on upper floors. It also indicates that enlarging the distance between outdoor units on different floors is an effective way to impair such thermal plume effect and improve the system thermal performance. For the studied case, a modified layout of VRF outdoor units is presented with floor interval, and the average inlet temperatures can be decreased by 22%. This work can provide guidance to the optimization layout design of practical VRF air conditioning systems used in high-rise buildings.
引用
收藏
页码:48 / 61
页数:14
相关论文
共 26 条
  • [1] Effect of welding polarity on bead geometry, microstructure, microhardness, and residual stresses of 1020 steel
    Aloraier, Abdulkareem
    Al-Fadhalah, Khaled
    Paradowska, Anna M.
    Alfaraj, Emad
    [J]. Journal of Engineering Research, 2014, 2 (04): : 137 - 160
  • [2] [Anonymous], 2006, Key World Energy Statistics
  • [3] Experimental evaluation of the ventilation effect on the performance of a VRV system in cooling mode - Part I: Experimental evaluation
    Aynur, Tolga N.
    Hwang, Yunho
    Radermacher, Reinhard
    [J]. HVAC&R RESEARCH, 2008, 14 (04): : 615 - 630
  • [4] CFD modelling of air flow and thermal performance of an atrium integrated with photovoltaics
    Gan, GH
    Riffat, SB
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (07) : 735 - 748
  • [5] A combined low temperature water heating system consisting of radiators and floor heating
    Hasan, Ala
    Kurnitski, Jarek
    Jokiranta, Kai
    [J]. ENERGY AND BUILDINGS, 2009, 41 (05) : 470 - 479
  • [6] MODIFIED COLLOCATED SIMPLEC ALGORITHM APPLIED TO BUOYANCY-AFFECTED TURBULENT-FLOW USING A MULTIGRID SOLUTION PROCEDURE
    JOHANSSON, P
    DAVIDSON, L
    [J]. NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1995, 28 (01) : 39 - 57
  • [7] Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD
    Karmare, S. V.
    Tikekar, A. N.
    [J]. SOLAR ENERGY, 2010, 84 (03) : 409 - 417
  • [8] Experimental validation of the simulation module of the water-cooled variable refrigerant flow system under cooling operation
    Li, Yue Ming
    Wu, Jing Yi
    Shiochi, Sumio
    [J]. APPLIED ENERGY, 2010, 87 (05) : 1513 - 1521
  • [9] Modeling and energy simulation of the variable refrigerant flow air conditioning system with water-cooled condenser under cooling conditions
    Li, Yueming
    Wu, Jingyi
    Shiochi, Sumio
    [J]. ENERGY AND BUILDINGS, 2009, 41 (09) : 949 - 957
  • [10] A review of recent development in variable refrigerant flow systems
    Lin, Xiaojie
    Lee, Hoseong
    Hwang, Yunho
    Radermacher, Reinhard
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (07) : 917 - 933