In vitro analysis of the flow fields of a rotary blood pump

被引:0
作者
Morsi, Y [1 ]
Yang, W [1 ]
Chan, S [1 ]
机构
[1] Swinburne Univ Technol, Sch Sci & Engn, Hawthorn, Vic 3122, Australia
来源
COMPUTATIONAL MECHANICS, VOLS 1 AND 2, PROCEEDINGS: NEW FRONTIERS FOR THE NEW MILLENNIUM | 2001年
关键词
rotary blood pump; laser Doppler anemometry; computational fluid dynamics;
D O I
暂无
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Thrombosis formation and hemolysis have been linked to the dynamics of the flowing blood and the hydrodynamic performance of the pump in a rotary blood pumps and ventricular assist devices (VADs). Hemolysis occurs as the blood passes through the pump housing and thrombosis in stagnation and low velocity regions. In our on-going research on VAD some experiments using LDA and CFD numerical analysis were performed on the Medtronic and Terumo blood pumps respectively. In this paper preliminary flow characteristics in terms of mean velocity and tangential velocity vectors are presented and discussed. These preliminary in vitro test data reveal that the use of LDA and CFD techniques are powerful tools in new pump designs and pump improvement.
引用
收藏
页码:875 / 880
页数:6
相关论文
共 50 条
  • [21] Experimental and Numerical Investigation of an Axial Rotary Blood Pump
    Schuele, Chan Yong
    Thamsen, Bente
    Bluemel, Bastian
    Lommel, Michael
    Karakaya, Tamer
    Paschereit, Christian Oliver
    Affeld, Klaus
    Kertzscher, Ulrich
    ARTIFICIAL ORGANS, 2016, 40 (11) : E192 - E202
  • [22] Paradoxical effects of viscosity on the VentrAssist rotary blood pump
    Vidakovic, S
    Ayre, P
    Woodard, J
    Lingard, N
    Tansley, G
    Reizes, J
    ARTIFICIAL ORGANS, 2000, 24 (06) : 478 - 482
  • [23] Bearing dynamic characteristics of the ventrassist rotary blood pump
    Chung, M
    Zhang, N
    Tansley, GD
    Woodard, JC
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON VIBRATION ENGINEERING, 2002, : 155 - 161
  • [24] Numerical Simulation of the Flow Field Inside the Rotary Pump
    Shi, Xiong
    Chen, Jun
    2011 INTERNATIONAL CONFERENCE ON COMPUTERS, COMMUNICATIONS, CONTROL AND AUTOMATION (CCCA 2011), VOL III, 2010, : 543 - 546
  • [25] A validated computational fluid dynamics model to estimate hemolysis in a rotary blood pump
    Arvand, A
    Hormes, M
    Reul, H
    ARTIFICIAL ORGANS, 2005, 29 (07) : 531 - 540
  • [26] The estimation of cardiac function from the rotary blood pump
    Nakata, K
    Shiono, M
    Akiyama, K
    Orime, Y
    Saito, A
    Tutomu, H
    Negishi, N
    Sezai, Y
    Sankai, T
    ARTIFICIAL ORGANS, 2001, 25 (09) : 709 - 712
  • [27] A two-stage rotary blood pump design with potentially lower blood trauma: a computational study
    Thamsen, Bente
    Mevert, Ricardo
    Lommel, Michael
    Preikschat, Philip
    Gaebler, Julia
    Krabatsch, Thomas
    Kertzscher, Ulrich
    Hennig, Ewald
    Affeld, Klaus
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2016, 39 (04) : 178 - 183
  • [28] Hemodynamic investigation and in vitro evaluation of a novel mixed-flow blood pump
    Qu, Yifei
    Guo, Ziyu
    Zhang, Jing
    Li, Guiling
    Zhang, Song
    Li, Donghai
    ARTIFICIAL ORGANS, 2022, 46 (08) : 1533 - 1543
  • [29] Magnetic Drive System for a New Centrifugal Rotary Blood Pump
    Hilton, Andrew
    Tansley, Geoff
    ARTIFICIAL ORGANS, 2008, 32 (10) : 772 - 777
  • [30] Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump
    Tompkins, Landon H.
    Gellman, Barry N.
    Morello, Gino F.
    Prina, Steven R.
    Roussel, Thomas J.
    Kopechek, Jonathan A.
    Petit, Priscilla C.
    Slaughter, Mark S.
    Koenig, Steven C.
    Dasse, Kurt A.
    ASAIO JOURNAL, 2021, 67 (09) : 1026 - 1035