In-vitro Study for Cerenkov Luminescence Imaging Application in Hepatic Metastasectomy

被引:2
作者
Ciarrocchi, Esther [1 ,2 ]
Saponaro, Sara [1 ]
Bartoli, Francesco [3 ]
Cataldi, Angela Gabriella [3 ]
Vitali, Sara [3 ,4 ]
Erba, Paola Anna [3 ,5 ]
Belcari, Nicola [1 ,2 ]
机构
[1] Univ Pisa, Dept Phys, Pisa, Italy
[2] Natl Inst Nucl Phys, Sect Pisa, Pisa, Italy
[3] Univ Pisa, Dept Translat Res New Technol Med & Surg, Pisa, Italy
[4] Azienda Unitaria Sanit Locale AUSL Piacenza, Piacenza, Italy
[5] Univ Hosp Pisa Azienda Osped Univ Pisana AOUP, Nucl Med Unit, Pisa, Italy
关键词
cerenkov luminescence imaging (CLI); image-guided surgery (IGS); margin assessment; detection limit; liver;
D O I
10.3389/fphy.2021.635540
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cerenkov luminescence imaging (CLI) has been recently proposed as a method to visualize surgical margins in the operating theater, immediately after resection, to allow refining surgery in a single procedure. Our group is preparing a pilot clinical study to evaluate the impact of CLI during hepatic metastasectomy, using F-18-FDG and Ga-68-DOTATOC. Currently, we are optimizing the clinical protocol in terms of patient inclusion criteria, activity to inject, maximum allowed delay for imaging, and radiation monitoring. This paper describes a preliminary study we have performed to define the clinical protocol. The study is composed of two branches: 1) an in-vitro study to predict the typical signals and optical attenuation in the liver with F-18 and Ga-68, 2) an analysis of clinical PET/CT data to determine typical values of relevant parameters, such as uptake and lesion dimension. The combined information by these two branches gives us an indication of the feasibility of CLI for margin assessment in liver metastasectomy. For Ga-68, we obtained detection limits ranging from 0.55 to 3.5 kBq/cc, to be compared with minimum and mean clinical uptakes of 1.6 and 7 kBq/cc, respectively. For F-18, the detection limits ranged from 12 to 145 kBq/cc, and the minimum and mean clinical uptakes were 5 and 11 kBq/cc, respectively. From these values, we expect CLI with Ga-68 to be able to detect surgical margins in most patients, while with F-18 the activities to inject for sufficient signal-to-noise ratio should be larger than standards, or the time delay between injection and imaging largely reduced. The results reported here can be useful also more in general, for studies dedicated to other CLI applications in the liver.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Weak biophoton emission after laser surgery application in soft tissues: Analysis of the optical features [J].
Boschi, Federico ;
Basso, Petra R. ;
Corridori, Darla ;
Durando, Giovanni ;
Sandri, Angela ;
Segalla, Gabriel ;
Raspanti, Mario ;
Spinelli, Antonello E. .
JOURNAL OF BIOPHOTONICS, 2019, 12 (09)
[2]   Performance evaluation of the LightPath imaging system for intra-operative Cerenkov luminescence imaging [J].
Ciarrocchi, Esther ;
Vanhove, Christian ;
Descamps, Benedicte ;
De Lombaerd, Stef ;
Vandenberghe, Stefaan ;
Belcari, Nicola .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 52 :122-128
[3]   Cerenkov luminescence imaging: physics principles and potential applications in biomedical sciences [J].
Ciarrocchi, Esther ;
Belcari, Nicola .
EJNMMI PHYSICS, 2017, 4
[4]   Intraoperative 68Ga-PSMA Cerenkov Luminescence Imaging for Surgical Margins in Radical Prostatectomy: A Feasibility Study [J].
Darr, Christopher ;
Harke, Nina N. ;
Radtke, Jan Philipp ;
Yirga, Leubet ;
Kesch, Claudia ;
Grootendorst, Maarten R. ;
Fendler, Wolfgang P. ;
Costa, Pedro Fragoso ;
Rischpler, Christoph ;
Praus, Christine ;
Haubold, Johannes ;
Reis, Henning ;
Hager, Thomas ;
Herrmann, Ken ;
Binse, Ina ;
Hadaschik, Boris .
JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (10) :1500-1506
[5]   Detection rate of unknown primary tumour by using somatostatin receptor PET/CT in patients with metastatic neuroendocrine tumours: a meta-analysis [J].
De Dosso, Sara ;
Treglia, Giorgio ;
Pascale, Mariarosa ;
Tamburello, Adriana ;
Santhanam, Prasanna ;
Kroiss, Alexander S. ;
Mestre, Ricardo Pereira ;
Saletti, Piercarlo ;
Giovanella, Luca .
ENDOCRINE, 2019, 64 (03) :456-468
[6]   Cerenkov luminescence imaging (CLI) for image-guided cancer surgery [J].
Grootendorst M.R. ;
Cariati M. ;
Kothari A. ;
Tuch D.S. ;
Purushotham A. .
Clinical and Translational Imaging, 2016, 4 (5) :353-366
[7]   Intraoperative Assessment of Tumor Resection Margins in Breast-Conserving Surgery Using 18F-FDG Cerenkov Luminescence Imaging: A First-in-Human Feasibility Study [J].
Grootendorst, Maarten R. ;
Cariati, Massimiliano ;
Pinder, Sarah E. ;
Kothari, Ashutosh ;
Douek, Michael ;
Kovacs, Tibor ;
Hamed, Hisham ;
Pawa, Amit ;
Nimmo, Fiona ;
Owen, Julie ;
Ramalingam, Vernie ;
Sethi, Sweta ;
Mistry, Sanjay ;
Vyas, Kunal ;
Tuch, David S. ;
Britten, Alan ;
Van Hemelrijck, Mieke ;
Cook, Gary J. ;
Sibley-Allen, Chris ;
Allen, Sarah ;
Purushotham, Arnie .
JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (06) :891-898
[8]   Performance evaluation of Cerenkov luminescence imaging: a comparison of 68Ga with 18F [J].
Heuvel, J. Olde ;
de Wit-van der Veen, B. J. ;
Vyas, K. N. ;
Tuch, D. S. ;
Grootendorst, M. R. ;
Stokkel, M. P. M. ;
Slump, C. H. .
EJNMMI PHYSICS, 2019, 6 (01)
[9]   68Ga-PSMA Cerenkov luminescence imaging in primary prostate cancer: first-in-man series [J].
Heuvel, Judith Olde ;
de Wit-van der Veen, Berlinda J. ;
van der Poel, Henk G. ;
Bekers, Elise M. ;
Grootendorst, Maarten R. ;
Vyas, Kunal N. ;
Slump, Cornelis H. ;
Stokkel, Marcel P. M. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (11) :2624-2632
[10]   Comparison of Diagnostic Sensitivity and Quantitative Indices Between 68Ga-DOTATOC PET/CT and 111In-Pentetreotide SPECT/CT in Neuroendocrine Tumors: a Preliminary Report [J].
Lee I. ;
Paeng J.C. ;
Lee S.J. ;
Shin C.S. ;
Jang J.-Y. ;
Cheon G.J. ;
Lee D.S. ;
Chung J.-K. ;
Kang K.W. .
Nuclear Medicine and Molecular Imaging, 2015, 49 (4) :284-290