In-vitro Study for Cerenkov Luminescence Imaging Application in Hepatic Metastasectomy

被引:1
|
作者
Ciarrocchi, Esther [1 ,2 ]
Saponaro, Sara [1 ]
Bartoli, Francesco [3 ]
Cataldi, Angela Gabriella [3 ]
Vitali, Sara [3 ,4 ]
Erba, Paola Anna [3 ,5 ]
Belcari, Nicola [1 ,2 ]
机构
[1] Univ Pisa, Dept Phys, Pisa, Italy
[2] Natl Inst Nucl Phys, Sect Pisa, Pisa, Italy
[3] Univ Pisa, Dept Translat Res New Technol Med & Surg, Pisa, Italy
[4] Azienda Unitaria Sanit Locale AUSL Piacenza, Piacenza, Italy
[5] Univ Hosp Pisa Azienda Osped Univ Pisana AOUP, Nucl Med Unit, Pisa, Italy
关键词
cerenkov luminescence imaging (CLI); image-guided surgery (IGS); margin assessment; detection limit; liver;
D O I
10.3389/fphy.2021.635540
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cerenkov luminescence imaging (CLI) has been recently proposed as a method to visualize surgical margins in the operating theater, immediately after resection, to allow refining surgery in a single procedure. Our group is preparing a pilot clinical study to evaluate the impact of CLI during hepatic metastasectomy, using F-18-FDG and Ga-68-DOTATOC. Currently, we are optimizing the clinical protocol in terms of patient inclusion criteria, activity to inject, maximum allowed delay for imaging, and radiation monitoring. This paper describes a preliminary study we have performed to define the clinical protocol. The study is composed of two branches: 1) an in-vitro study to predict the typical signals and optical attenuation in the liver with F-18 and Ga-68, 2) an analysis of clinical PET/CT data to determine typical values of relevant parameters, such as uptake and lesion dimension. The combined information by these two branches gives us an indication of the feasibility of CLI for margin assessment in liver metastasectomy. For Ga-68, we obtained detection limits ranging from 0.55 to 3.5 kBq/cc, to be compared with minimum and mean clinical uptakes of 1.6 and 7 kBq/cc, respectively. For F-18, the detection limits ranged from 12 to 145 kBq/cc, and the minimum and mean clinical uptakes were 5 and 11 kBq/cc, respectively. From these values, we expect CLI with Ga-68 to be able to detect surgical margins in most patients, while with F-18 the activities to inject for sufficient signal-to-noise ratio should be larger than standards, or the time delay between injection and imaging largely reduced. The results reported here can be useful also more in general, for studies dedicated to other CLI applications in the liver.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] NICOTINAMIDE METHYLATION AND HEPATIC ENERGY RESERVE - A STUDY BY LIVER PERFUSION IN-VITRO
    CUOMO, R
    PUMPO, R
    SARNELLI, G
    CAPUANO, G
    BUDILLON, G
    JOURNAL OF HEPATOLOGY, 1995, 23 (04): : 465 - 470
  • [2] Intraoperative 68Ga-PSMA Cerenkov Luminescence Imaging for Surgical Margins in Radical Prostatectomy: A Feasibility Study
    Darr, Christopher
    Harke, Nina N.
    Radtke, Jan Philipp
    Yirga, Leubet
    Kesch, Claudia
    Grootendorst, Maarten R.
    Fendler, Wolfgang P.
    Costa, Pedro Fragoso
    Rischpler, Christoph
    Praus, Christine
    Haubold, Johannes
    Reis, Henning
    Hager, Thomas
    Herrmann, Ken
    Binse, Ina
    Hadaschik, Boris
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61 (10) : 1500 - 1506
  • [3] METABOLISM OF DILTIAZEM IN HEPATIC AND EXTRAHEPATIC TISSUES OF RABBITS - IN-VITRO STUDIES
    HOMSY, W
    LEFEBVRE, M
    CAILLE, G
    DUSOUICH, P
    PHARMACEUTICAL RESEARCH, 1995, 12 (04) : 609 - 614
  • [4] Hepatic Perfusion Imaging: Concepts and Application
    Haider, Masoom A.
    Farhadi, Farzin A.
    Milot, Laurent
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2010, 18 (03) : 465 - +
  • [5] A comparative experimental study of the in-vitro efficiency of hypertonic saline-enhanced hepatic bipolar and monopolar radiofrequency ablation
    Lee, JM
    Han, JK
    Kim, SH
    Sohn, KL
    Lee, KH
    Ah, SK
    Choi, BI
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (03) : 163 - 169
  • [6] Noncontact versus contact imaging: An atomic force microscopic study on hepatic endothelial cells in vitro
    Braet, F
    DeZanger, R
    Kammer, S
    Wisse, E
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1997, 8 (02) : 162 - 167
  • [7] Application of radionuclide imaging to hepatic impact injury in rabbits
    金榕兵
    麻晓林
    温建良
    唐维佳
    中华创伤杂志(英文版), 2004, (01) : 45 - 48
  • [8] HEPATIC AMINO-ACID-UPTAKE IS DECREASED IN LACTATING RATS - IN-VIVO AND IN-VITRO STUDIES
    DELAASUNCION, JG
    DEVESA, A
    VINA, JR
    BARBER, T
    JOURNAL OF NUTRITION, 1994, 124 (11) : 2163 - 2171
  • [9] Radiation Protection and Occupational Exposure on 68Ga-PSMA-11-Based Cerenkov Luminescence Imaging Procedures in Robot-Assisted Prostatectomy
    Costa, Pedro Fragoso
    Fendler, Wolfgang P.
    Herrmann, Ken
    Sandach, Patrick
    Grafe, Hong
    Grootendorst, Maarten R.
    Puellen, Lukas
    Kesch, Claudia
    Krafft, Ulrich
    Radtke, Jan P.
    Tschirdewahn, Stephan
    Hadaschik, Boris A.
    Darr, Christopher
    JOURNAL OF NUCLEAR MEDICINE, 2022, 63 (09) : 1349 - 1356
  • [10] IN-VITRO AND IN-VIVO REGULATION OF HEPATIC MITOGEN-ACTIVATED PROTEIN-KINASES IN FETAL RATS
    BOYLAN, JM
    GRUPPUSO, PA
    AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 1994, 267 (06): : G1078 - G1086