Apical left ventricular radiotracer uptake on attenuation correction with SPECT/TDM myocardial perfusion scintigraphy in non-ischemic patients

被引:0
作者
Dechmi-Khiar, A. [1 ]
Amegassi, F. [1 ]
Kotbi, O. [1 ]
Clerc, J. [1 ]
Daou, D. [1 ,2 ]
机构
[1] CHU Cochin, AP HP, Dept Med Nucl, 27 Rue Faubourg St Jacques, F-75679 Paris 14, France
[2] Univ Paris Diderot, Sorbonne Paris Cite, EA REMES 7334, Paris, France
来源
MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE | 2018年 / 42卷 / 02期
关键词
Attenuation correction; Apical thinning; SPECT/CT; Myocardial perfusion scintigraphy; CORONARY-ARTERY-DISEASE; COMPUTED-TOMOGRAPHY; CARDIAC SPECT; TRANSMISSION; RESOLUTION; ACCURACY; IMAGES; CT;
D O I
10.1016/j.mednuc.2018.02.003
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Introduction. - Attenuation correction (AC) has been shown to improve the accuracy of myocardial perfusion single photon emission computed scintigraphy (SPECT). It often reveals a decrease in apical uptake in the AC of the left ventricular (LV) in non-ischemic patients. We aimed to identify the parameters that could affect the apical radiotracer uptake in non-ischemic patients. Materials and methods. - Prospectively, we included 340 consecutive non-ischemic patients. They underwent sequential CT and myocardial SPECT imaging. We studied the apical uptake with the AC (combined to scatter correction, resolution recovery and noise regularization) and its correlation with various parameters related to patient and the technique. Results. - The apical uptake with AC was lower than with filtered back projection (FBP). On univariate analysis, several parameters correlated to apical uptake with AC, of which only 4 remained significant on step-by-step regression analysis: uptake with FBP, angle of the LV in the frontal plane, type of stress, arm's position at acquisition. These four parameters explain 51% of the variation of apical uptake with CA. Conclusions. - Apical uptake in myocardial perfusion scintigraphy is lower with AC compared with RPF in non-ischemic patients. The apical uptake with AC is correlated to that of FBP, angle of the LV in the frontal plane, type of stress and arm's position at acquisition. (C) 2018 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:88 / 96
页数:9
相关论文
共 19 条
  • [1] Apostolopoulos DJ, 2016, HELL J NUCL MED, V19, P89, DOI 10.1967/s0024499100360
  • [2] Improvement of image resolution and quantitative accuracy in clinical Single Photon Emission Computed Tomography
    Beekman, FJ
    Kamphuis, C
    King, MA
    van Rijk, PP
    Viergever, MA
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2001, 25 (02) : 135 - 146
  • [3] BRADFIELD JWB, 1977, BRIT HEART J, V39, P806
  • [4] FICARO EP, 1995, J NUCL MED, V36, P921
  • [5] Attenuation and scatter compensation in myocardial perfusion SPECT
    Galt, JR
    Cullom, SJ
    Garcia, EV
    [J]. SEMINARS IN NUCLEAR MEDICINE, 1999, 29 (03) : 204 - 220
  • [6] Prevalence of misregistration between SPECT and CT for attenuation-corrected myocardial perfusion SPECT
    Goetze, Sibyll
    Wahl, Richard L.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) : 200 - 206
  • [7] Effect of patient obesity on the accuracy of thallium-201 myocardial perfusion imaging
    Hansen, CL
    Woodhouse, S
    Kramer, M
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (06) : 749 - 752
  • [8] The value and practice of attenuation correction for myocardial perfusion SPECT imaging: A joint position statement from the American Society of Nuclear Cardiology and the Society of Nuclear Medicine
    Hendel, RC
    Corbett, JR
    Cullom, SJ
    DePuey, EG
    Garcia, EV
    Bateman, TM
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (01) : 135 - 143
  • [9] EANM/ESC guidelines for radionuclide imaging of cardiac function
    Hesse, B.
    Lindhardt, T. B.
    Acampa, W.
    Anagnostopoulos, C.
    Ballinger, J.
    Bax, J. J.
    Edenbrandt, L.
    Flotats, A.
    Germano, G.
    Stopar, T. Gmeiner
    Franken, P.
    Kelion, A.
    Kjaer, A.
    Le Guludec, D.
    Ljungberg, M.
    Maenhout, A. F.
    Marcassa, C.
    Marving, J.
    McKiddie, F.
    Schaefer, W. M.
    Stegger, L.
    Underwood, R.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (04) : 851 - 885
  • [10] Diagnostic Performance of Attenuation-Corrected Myocardial Perfusion Imaging for Coronary Artery Disease: A Systematic Review and Meta-Analysis
    Huang, Jei-Yie
    Huang, Chun-Kai
    Yen, Ruoh-Fang
    Wu, Hon-Yen
    Tu, Yu-Kang
    Cheng, Mei-Fang
    Lu, Ching-Chu
    Tzen, Kai-Yuan
    Chien, Kuo-Liong
    Wu, Yen-Wen
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (12) : 1893 - 1898