Challenges of implementing Point-of-Care Testing (POCT) glucose meters in a pediatric acute care setting

被引:20
作者
Kavsak, PA
Zielinski, N
Li, DL
McNamara, PJ
Adeli, K
机构
[1] Univ Toronto, Hosp Sick Children, Div Clin Biochem, Toronto, ON M5G 1X8, Canada
[2] Univ Toronto, Hosp Sick Children, Div Neonatol, Toronto, ON M5G 1X8, Canada
关键词
glucose measurements; NICU; glucose meters; Point-of-Care Testing; POCT;
D O I
10.1016/j.clinbiochem.2004.06.003
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: To investigate factors contributing to analytical bias in POCT glucose values generated by the NICU versus the core laboratory. Methods: The LifeScan Flexx hospital system glucose meters (SureStep) were used in precision and comparison studies between the NICU and laboratory (ABL715 and Vitros 950). Results: Analysis of 40 neonatal blood samples revealed a positive bias between the NICU glucose meters versus either the laboratory glucose meter or instrument (mean difference of 0.28 and 0.21 mmol/L, respectively). Linear regression analysis (R-2 = 0.0584) of the difference in glucose results versus time elapsed between measurements indicated that the bias observed between the NICU and laboratory glucose meters was not due to in vitro glycolysis for samples transported on ice. Further analysis indicated that the bias appeared to be mostly operator driven, with different NICU operators exhibiting different mean biases. Increasing the amount of blood applied to the SureStep Pro test strip (e.g., 60 vs. 20 muL), led to higher values for glucose concentration for the same blood. Nearly 50% of all glucose values reported for the NICU were obtained by the SureStep Flexx glucose meters in a 3-month period following the introduction of POCT, yet the number of laboratory-reported glucose results for the same period increased by 21% as compared to the previous year. Conclusions: Operator error appears to be a source of bias present between the NICU and laboratory, and despite glucose meter utilization in the NICU, the number of glucose measurements by the central laboratory increased after POCT introduction. (C) 2004 The Canadian Society of Clinical Chemists. All rights reserved.
引用
收藏
页码:811 / 817
页数:7
相关论文
共 50 条
  • [21] Point-of-care testing in haemostasis
    Perry, David J.
    Fitzmaurice, David A.
    Kitchen, Steve
    Mackie, Ian J.
    Mallett, Sue
    BRITISH JOURNAL OF HAEMATOLOGY, 2010, 150 (05) : 501 - 514
  • [22] Point-of-Care Pregnancy Testing
    Sluss, Patrick M.
    POINT OF CARE, 2016, 15 (04): : 164 - 171
  • [23] The Future of Point-of-Care Testing
    Nichols, James H.
    POINT OF CARE, 2008, 7 (04): : 271 - 273
  • [24] Point-of-care testing: An introduction
    Gutierres, SL
    Welty, TE
    ANNALS OF PHARMACOTHERAPY, 2004, 38 (01) : 119 - 125
  • [25] Quality in point-of-care testing
    Nichols, JH
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2003, 3 (05) : 563 - 572
  • [26] Osteoporosis: Point-of-care testing
    DeHart, RM
    Gonzalez, EH
    ANNALS OF PHARMACOTHERAPY, 2004, 38 (03) : 473 - 481
  • [27] Lactate and point-of-care testing
    Mizock, BA
    CRITICAL CARE MEDICINE, 1998, 26 (09) : 1474 - 1476
  • [28] Point-of-care testing of proteins
    Axel Warsinke
    Analytical and Bioanalytical Chemistry, 2009, 393 : 1393 - 1405
  • [29] Point-of-care testing of proteins
    Warsinke, Axel
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (05) : 1393 - 1405
  • [30] Accuracy and precision of point-of-care testing for glucose and prothrombin time at the critical care units
    Yuoh, C
    Elghetany, MT
    Petersen, JR
    Mohammad, A
    Okorodudu, AO
    CLINICA CHIMICA ACTA, 2001, 307 (1-2) : 119 - 123