SOLED STATE DETECTORS FOR QUALITY ASSURANCE IN BRACHYTHERAPY

被引:0
|
作者
Marinello, Ginette [1 ]
机构
[1] CHU Henri Mondor, Unite Radiophys & Radioprotect, F-94000 Creteil, France
来源
RADIOTHERAPY AND BRACHYTHERAPY | 2009年
关键词
Brachytherapy; solid state detectors; diodes; MOSFETs; EPR-alanine; Gafchromic films; plastic scintillators; TLD; RADIOCHROMIC FILM; DOSIMETRY; ENERGY; RADIATION; SCINTILLATORS; DEPENDENCE; SCANNER; PHOTON;
D O I
10.1007/978-90-481-3097-9_20
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Because of the low energy of photon or beta radioactive sources currently used for modem techniques of brachytherapy, and the high dose gradient existing around them, the dosimeters to be used for quality controls of the sources or absorbed dose measurements should have special characteristics such as an accurate and reproducible response, a low dose response dependence as a function of energy, a high sensitivity under a small volume, a response independent of the dose-rate, etc. Commercial solid state detectors, such as diodes, MOSFETs, EPR-alanine, Gafchromic films, plastic scintillators and radiothermoluminescent (RTL) dosimeters, can be interesting in the concerned field. After a brief reminder of their principle, a review of their dosimetric advantages and disadvantages is presented. A selection of detectors the best suited for brachytherapy with examples of use for quality assurance controls or in-vivo dosimetry is also presented.
引用
收藏
页码:227 / 237
页数:11
相关论文
共 50 条
  • [21] A system to use electromagnetic tracking for the quality assurance of brachytherapy catheter digitization
    Damato, Antonio L.
    Viswanathan, Akila N.
    Don, Sarah M.
    Hansen, Jorgen L.
    Cormack, Robert A.
    MEDICAL PHYSICS, 2014, 41 (10)
  • [22] Performance assessment of a 2D array of plastic scintillation detectors for IMRT quality assurance
    Guillot, Mathieu
    Gingras, Luc
    Archambault, Louis
    Beddar, Sam
    Beaulieu, Luc
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (13): : 4439 - 4454
  • [23] Monte Carlo calculation of beam quality correction for solid-state detectors and phantom scatter correction at 137Cs energy
    Selvam, T. Palani
    Mishra, Subhalaxmi
    Vishwakarma, R. S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 339 - 350
  • [24] The Effect of Dose and Quality Assurance in Early Prostate Cancer Treated with Low Dose Rate Brachytherapy as Monotherapy
    Henry, A. M.
    Rodda, S. L.
    Mason, M.
    Musurunu, H.
    Al-Qaisieh, B.
    Bownes, P.
    Smith, J.
    Franks, K.
    Carey, B.
    Bottomley, D.
    CLINICAL ONCOLOGY, 2015, 27 (07) : 382 - 386
  • [25] Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector
    Golshan, Maryam
    Spadinger, Ingrid
    Chng, Nick
    MEDICAL PHYSICS, 2016, 43 (06) : 3008 - 3018
  • [26] Recommendations of the American Association of Physicists in Medicine on dosimetry, imaging, and quality assurance procedures for 90Y microsphere brachytherapy in the treatment of hepatic malignancies
    Dezarn, William A.
    Cessna, Jeffery T.
    DeWerd, Larry A.
    Feng, Wenzheng
    Gates, Vanessa L.
    Halama, James
    Kennedy, Andrew S.
    Nag, Subir
    Sarfaraz, Mehrdad
    Sehgal, Varun
    Selwyn, Reed
    Stabin, Michael G.
    Thomadsen, Bruce R.
    Williams, Lawrence E.
    Salem, Riad
    MEDICAL PHYSICS, 2011, 38 (08) : 4824 - 4845
  • [27] Innovative detectors for quality assurance dosimetry in SBRT of stationary and movable targets
    Newall, M. K.
    Petasecca, M.
    Duncan, M.
    Fuduli, I.
    Al Shukaili, K.
    Booth, J. T.
    Keall, P.
    Corde, S.
    Pereveratylo, V.
    Lerch, M.
    Rosenfeld, A. B.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777
  • [28] GEC-ESTRO/ACROP recommendations for quality assurance of ultrasound imaging in brachytherapy
    Siebert, Frank-Andre
    Kirisits, Christian
    Hellebust, Taran Paulsen
    Baltas, Dimos
    Verhaegen, Frank
    Camps, Saskia
    Pieters, Bradley
    Kovacs, Gyorgy
    Thomadsen, Bruce
    RADIOTHERAPY AND ONCOLOGY, 2020, 148 : 51 - 56
  • [29] Fluorescent screen for high-dose-rate (HDR) brachytherapy quality assurance
    Lightstone, AW
    MEDICAL DOSIMETRY, 2005, 30 (03) : 143 - 144
  • [30] Imaging Cherenkov emission for quality assurance of high-dose-rate brachytherapy
    Yogo, Katsunori
    Matsushita, Akihiro
    Tatsuno, Yuya
    Shimo, Takahiro
    Hirota, Seiko
    Nozawa, Marika
    Ozawa, Shuichi
    Ishiyama, Hiromichi
    Yasuda, Hiroshi
    Nagata, Yasushi
    Hayakawa, Kazushige
    SCIENTIFIC REPORTS, 2020, 10 (01)