Lifetime Absolute Calibration of the EO-1 Hyperion Sensor and its Validation

被引:15
作者
Jing, Xin [1 ,2 ]
Leigh, Larry [1 ]
Helder, Dennis [1 ]
Pinto, Cibele Teixeira [1 ]
Aaron, David [1 ]
机构
[1] South Dakota State Univ, Coll Engn, Image Proc Lab, Brookings, SD 57007 USA
[2] Univ Maryland, Dept Astron, College Pk, MD 20740 USA
来源
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING | 2019年 / 57卷 / 11期
关键词
Calibration; Radiometry; Stability analysis; Orbits; Uncertainty; Market research; Cloud computing; All bands; calibration; Hyperion; lifetime; stability; RADIOMETRIC CALIBRATION; VICARIOUS CALIBRATION; IMAGING SPECTROMETER; RAILROAD VALLEY; LANDSAT; PERFORMANCE; STABILITY; RADIANCE; MISSION;
D O I
10.1109/TGRS.2019.2926663
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
The Earth-Observing One Hyperion sensor was decommissioned on March 20, 2017. Analysis of Libya 4 Pseudo-Invariant Calibration Sites (PICSs) image data acquired from 2004 to final decommissioning indicated statistically significant drifts in sensor response in the bands 8 to 16 (426.82, 436.99, 447.17, 457.34, 467.52, 477.69, 487.87, 498.04, and 508.22 nm) and bands 206 (2213.93 nm), 209 (2244.22 nm), and 210 (2254.22 nm). The estimated yearly drift in these bands ranges between 0.136 and 0.049. After correction accounting for the estimated drift, the absolute radiometric calibration of the sensor was evaluated through vicarious reflectance-based calibrations performed at the South Dakota State University (SDSU) test site and the Radiometric Calibration Network (RadCalNet) Railroad Valley site using data from 2002 to 2015. Calibration correction coefficients including gain as much as 1.40 and bias as large as 0.132 were found except absorption bands (890980, 10901180, 13051520, and 17502050 nm). Finally, the yearly drift and calibration correction coefficients were validated by comparison of the banded multispectral Hyperion data after any significant drift and calibration coefficient correction with Landsat 7 data. The validation showed that after drift and calibration coefficient correction, there is no significant gain and bias using different test sites at different signal levels. The drift and calibration correction coefficients of each band are provided in this paper.
引用
收藏
页码:9466 / 9475
页数:10
相关论文
共 27 条
[1]   Design and calibration of field deployable ground-viewing radiometers [J].
Anderson, Nikolaus ;
Czapla-Myers, Jeffrey ;
Leisso, Nathan ;
Biggar, Stuart ;
Burkhart, Charles ;
Kingston, Rob ;
Thome, Kurtis .
APPLIED OPTICS, 2013, 52 (02) :231-240
[2]  
[Anonymous], 2016, QA4EOWGCVIVOCSP002RV
[3]   Landsat-7 mission and early results [J].
Barker, JL ;
Dolan, SK ;
Sabelhaus, PA ;
Williams, DL ;
Irons, JR ;
Markham, BL ;
Bolek, JT ;
Scott, SS ;
Thompson, RJ ;
Rapp, JJ ;
Arvidson, TJ ;
Kane, JF ;
Storey, JC .
SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES III, 1999, 3870 :299-311
[4]  
Barry P., 2001, EO-1/Hyperion Science Data User's Guide.
[5]   Landsat-7 ETM+ Radiometric Calibration Status [J].
Barsi, Julia A. ;
Markham, Brian L. ;
Czapla-Myers, Jeffrey S. ;
Helder, Dennis L. ;
Hook, Simon J. ;
Schott, John R. ;
Haque, Md. Obaidul .
EARTH OBSERVING SYSTEMS XXI, 2016, 9972
[6]   Vicarious radiometric calibration of EO-1 sensors by reference to high-reflectance ground targets [J].
Biggar, SF ;
Thome, KJ ;
Wisniewski, W .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2003, 41 (06) :1174-1179
[7]   EO-1 Hyperion Reflectance Time Series at Calibration and Validation Sites: Stability and Sensitivity to Seasonal Dynamics [J].
Campbell, Petya K. Entcheva ;
Middleton, Elizabeth M. ;
Thome, Kurt J. ;
Kokaly, Raymond F. ;
Huemmrich, Karl Fred ;
Lagomasino, David ;
Novick, Kimberly A. ;
Brunsell, Nathaniel A. .
IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2013, 6 (02) :276-290
[8]   Overview of Intercalibration of Satellite Instruments [J].
Chander, Gyanesh ;
Hewison, Tim J. ;
Fox, Nigel ;
Wu, Xiangqian ;
Xiong, Xiaoxiong ;
Blackwell, William J. .
IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (03) :1056-1080
[9]   Monitoring on-orbit calibration stability of the Terra MODIS and Landsat 7 ETM+ sensors using pseudo-invariant test sites [J].
Chander, Gyanesh ;
Xiong, Xiaoxiong ;
Choi, Taeyoung ;
Angal, Amit .
REMOTE SENSING OF ENVIRONMENT, 2010, 114 (04) :925-939
[10]   Validation of EO-1 Hyperion and Advanced Land Imager Using the Radiometric Calibration Test Site at Railroad Valley, Nevada [J].
Czapla-Myers, Jeffrey ;
Ong, Lawrence ;
Thome, Kurtis ;
McCorkel, Joel .
IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2016, 9 (02) :816-826