Study of beam profile measurement at interaction point in international linear collider

被引:4
作者
Ito, Kazutoshi [1 ]
Miyamoto, Akiya [2 ]
Nagamine, Tadashi [1 ]
Tauchi, Toshiaki [2 ]
Yamamoto, Hitoshi [1 ]
Takubo, Yosuke [1 ]
Sato, Yutaro [1 ]
机构
[1] Tohoku Univ, Dept Phys, Sendai, Miyagi 980, Japan
[2] High Energy Accelerator Res Org, KEK, Tsukuba, Ibaraki 3050801, Japan
关键词
ILC; Beam profile; Pair monitor; Interaction point;
D O I
10.1016/j.nima.2009.07.027
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
At the international linear collider, measurement of the beam profile at the interaction point is a key issue to achieve high luminosity. We report a simulation study on a new beam profile monitor, called the pair monitor, which uses the hit distribution of the electron-positron pairs generated at the interaction point. We obtained measurement accuracies of 5.1%, 10.0%, and 4.0% for the horizontal (sigma(x)), vertical (sigma(y)), and longitudinal beam sizes (sigma(z)), respectively, for 50 bunch crossings. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 371
页数:5
相关论文
共 7 条
[1]  
*ILC GLOB DES EFF, 2007, INT LIN COLL REF DES
[2]  
SCHULTE D, 1996, STUDY ELECTROMAGNETI
[3]  
Stahl A., 2005, LCDET2005003
[4]  
TAKUBO Y, 2007, P LCWS
[5]  
Tauchi T., 1993, Particle Accelerators, V41, P29
[6]  
TAUCHI T, 1995, NANOMETER BEAM SIZE
[7]  
TERNICK M, 2002, FAST BEAM DIAGNOSTIC