Internally cooled bipolar radiofrequency ablation:: Is a lower power output more effective?

被引:10
|
作者
Clasen, S.
Geng, A.
Herberts, T.
Boss, A.
Schmidt, D.
Schraml, C.
Fritz, J.
Kroeber, S. M.
Claussen, C. D.
Pereira, P. L.
机构
[1] Univ Klinikum Tubingen, Radiol Klin, D-72076 Tubingen, Germany
[2] Univ Tubingen, Inst Med Biometrie, D-72074 Tubingen, Germany
[3] Univ Tubingen, Inst Pathol, D-72074 Tubingen, Germany
关键词
radiofrequency ablation; abdomen; ablation procedures; technology assessment; liver; bipolar;
D O I
10.1055/s-2006-927360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of bipolar radiofrequency (RF) ablation using internally cooled electrodes in an ex-vivo experiment. Materials and Methods: Bipolar RF ablations (n = 154) were performed in ex-vivo bovine liver. Both electrodes with a total length of the active tip of 4 cm were located on the same shaft of an internally cooled applicator. The power output was systematically varied between 20 and 100 watts (W). The energy application was continuous or modulated depending on the tissue resistance. In relationship to the maximum power output, the volume of coagulation was assessed. Results: In continuous energy application the induced volume of coagulation was increased at lower power outputs up to 33.7 cm(3) (20 watts). Parallel to an increased volume of coagulation, the required duration of energy application was increased up to a maximum of 51.6 minutes. Modulation of the power output as a function of the tissue resistance enabled application of a wide range of power outputs (40-75 watts) leading to a comparable extent of coagulation with a maximum of 14.9 cm(3) (10min.), 16.8 cm(3) (15 min.),and 19.1 cm(3) (20 min.). Conclusion: Continuous application of RF energy leads to an inverse relationship between volume of coagulation and power output. Modulation of the power output as a function of the tissue resistance enables application of a wider range of power outputs compared to continuous application of RIF energy.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 50 条
  • [31] Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode
    Jeong Min Lee
    Joon Koo Han
    Se Hyung Kim
    Jae Young Lee
    Hee Sun Park
    Hong Eo
    Byung Ihn Choi
    European Radiology, 2005, 15 (11) : 2385 - 2385
  • [32] Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode
    Joon Koo Han
    Jeong Min Lee
    Se Hyung Kim
    Jae Young Lee
    Hee Sun Park
    Hong Eo
    Byung Ihn Choi
    European Radiology, 2005, 15 : 2163 - 2170
  • [33] Efficacy of a cooled bipolar epicardial radiofrequency ablation probe for creating transmural myocardial lesions
    Wood, Mark A.
    Ellenbogen, Amy L.
    Pathak, Vishesh
    Ellenbogen, Kenneth A.
    Kasarajan, Vigneshwar
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (02): : 453 - 458
  • [34] Radiofrequency ablation in the liver using two cooled-wet electrodes in the bipolar mode
    Jeong Min Lee
    Joon Koo Han
    Se Hyung Kim
    Jae Young Lee
    Hee Sun Park
    Hong Eo
    Byung Ihn Choi
    European Radiology, 2005, 15 : 2171 - 2171
  • [35] Intraoperative radiofrequency ablation using a loop internally cooled-perfusion electrode:: In vitro and in vivo experiments
    Lee, JM
    Han, JK
    Eoh, H
    Kim, SH
    Lee, JY
    Lee, MW
    Choi, BI
    JOURNAL OF SURGICAL RESEARCH, 2006, 131 (02) : 215 - 224
  • [36] Radiofrequency Ablation with an Internally Cooled Monopolar Directional Electrode: Ex Vivo and in Vivo Experimental Studies in the Liver
    Yu, Mi Hye
    Lee, Jae Young
    Jun, Su Ryoung
    Kim, Kyung Won
    Kim, Se Hyung
    Han, Joon Koo
    Choi, Byung Ihn
    RADIOLOGY, 2016, 278 (02) : 395 - 404
  • [37] Comparison of Internally Cooled Wet Electrode and Hepatic Vascular Inflow Occlusion Method for Hepatic Radiofrequency Ablation
    Park, Mi-Hyun
    Cho, June-Sik
    Shin, Byung Seok
    Jeon, Gyeong Sik
    Lee, Byungmo
    Lee, Kichang
    GUT AND LIVER, 2012, 6 (04) : 471 - 475
  • [38] Utility of tip thermometry during radiofrequency ablation in humans using an internally perfused saline cooled catheter
    Wharton, JM
    Wilber, DJ
    Calkins, H
    Epstein, AE
    Ellenbogen, KA
    Carlson, MD
    Stevenson, WG
    Packer, DL
    Hummel, J
    Stark, S
    Kopelman, H
    Tohou, PJ
    CIRCULATION, 1997, 96 (08) : 1775 - 1775
  • [39] Percutaneous radiofrequency ablation of HCC: reduced ablation duration and increased ablation size using single, internally cooled electrodes with an optimized pulsing algorithm
    Solbiati, Luigi
    Ierace, Tiziana
    Gennaro, Nicolo
    Muglia, Riccardo
    Cosman, Eric R., Jr.
    Goldberg, S. Nahum
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2020, 37 (01) : 861 - 867
  • [40] Radiofrequency ablation using internally cooled wet electrodes in bipolar mode for the treatment of recurrent hepatocellular carcinoma after locoregional treatment: A randomized prospective comparative study
    Choi, Jae Won
    Lee, Jeong Min
    Lee, Dong Ho
    Yoon, Jung-Hwan
    Kim, Yoon Jun
    Lee, Jeong-Hoon
    Yu, Su Jong
    Cho, Eun Ju
    PLOS ONE, 2020, 15 (09):