Internally cooled bipolar radiofrequency ablation:: Is a lower power output more effective?

被引:10
|
作者
Clasen, S.
Geng, A.
Herberts, T.
Boss, A.
Schmidt, D.
Schraml, C.
Fritz, J.
Kroeber, S. M.
Claussen, C. D.
Pereira, P. L.
机构
[1] Univ Klinikum Tubingen, Radiol Klin, D-72076 Tubingen, Germany
[2] Univ Tubingen, Inst Med Biometrie, D-72074 Tubingen, Germany
[3] Univ Tubingen, Inst Pathol, D-72074 Tubingen, Germany
关键词
radiofrequency ablation; abdomen; ablation procedures; technology assessment; liver; bipolar;
D O I
10.1055/s-2006-927360
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of bipolar radiofrequency (RF) ablation using internally cooled electrodes in an ex-vivo experiment. Materials and Methods: Bipolar RF ablations (n = 154) were performed in ex-vivo bovine liver. Both electrodes with a total length of the active tip of 4 cm were located on the same shaft of an internally cooled applicator. The power output was systematically varied between 20 and 100 watts (W). The energy application was continuous or modulated depending on the tissue resistance. In relationship to the maximum power output, the volume of coagulation was assessed. Results: In continuous energy application the induced volume of coagulation was increased at lower power outputs up to 33.7 cm(3) (20 watts). Parallel to an increased volume of coagulation, the required duration of energy application was increased up to a maximum of 51.6 minutes. Modulation of the power output as a function of the tissue resistance enabled application of a wide range of power outputs (40-75 watts) leading to a comparable extent of coagulation with a maximum of 14.9 cm(3) (10min.), 16.8 cm(3) (15 min.),and 19.1 cm(3) (20 min.). Conclusion: Continuous application of RF energy leads to an inverse relationship between volume of coagulation and power output. Modulation of the power output as a function of the tissue resistance enables application of a wider range of power outputs compared to continuous application of RIF energy.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 50 条
  • [1] Radiofrequency renal ablation: In vivo comparison of internally cooled, multitined expandable and internally cooled perfusion electrodes
    Lee, JM
    Han, JK
    Chang, JM
    Chung, SY
    Son, KR
    Kim, SH
    Lee, JY
    Choi, BI
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (03) : 549 - 556
  • [2] Computational modeling of radiofrequency ablation with an internally cooled wet electrode
    Ewertowska, E.
    Quesada-Diez, R.
    Radosevic, A.
    Andaluz, A.
    Moll, X.
    Berjano, E.
    Burdio, F.
    Trujillo, M.
    EMBEC & NBC 2017, 2018, 65 : 1069 - 1072
  • [3] A comparison of microwave ablation and bipolar radiofrequency ablation both with an internally cooled probe: Results in ex vivo and in vivo porcine livers
    Yu, Jie
    Liang, Ping
    Yu, Xiaoling
    Liu, Fangyi
    Chen, Lei
    Wang, Yang
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 124 - 130
  • [4] Percutaneous Radiofrequency Ablation with Internally Cooled versus Internally Cooled Wet Electrodes for Small Subphrenic Hepatocellular Carcinomas
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (03) : 351 - 356
  • [5] Comparison of Microwave Ablation and Multipolar Radiofrequency Ablation In Vivo Using Two Internally Cooled Probes
    Fan, WeiJun
    Li, Xin
    Zhang, Liang
    Jiang, Hua
    Zhang, JianLei
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : W46 - W50
  • [6] Radiofrequency Ablation with an Internally Cooled Electrode for Twin Reversed Arterial Perfusion Sequence
    Wagata, Maiko
    Murakoshi, Takeshi
    Ishii, Keisuke
    Muromoto, Jin
    Sasahara, Jun
    Murotsuki, Jun
    FETAL DIAGNOSIS AND THERAPY, 2016, 40 (02) : 110 - 115
  • [7] Switching bipolar hepatic radiofrequency ablation using internally cooled wet electrodes: comparison with consecutive monopolar and switching monopolar modes
    Yoon, J. H.
    Lee, J. M.
    Woo, S.
    Hwang, E. J.
    Hwang, I.
    Choi, W.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1050):
  • [8] CT findings after radiofrequency ablation in rabbit livers: Comparison of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion electrodes
    Kim, Seung Kwon
    Gu, Myung Seo
    Hong, Hyun Pyo
    Choi, Dongil
    Chae, Seoung Wan
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (11) : 1417 - 1427
  • [9] Percutaneous Radiofrequency Ablation Using Internally Cooled Wet Electrodes for the Treatment of Hepatocellular Carcinoma
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 471 - 476
  • [10] Radiofrequency Ablation in the Treatment of Large Hepatic Hemangiomas A Comparison of Multitined and Internally Cooled Electrodes
    Gao, Jun
    Ding, Xuemei
    Ke, Shan
    Xin, Zonghai
    Ning, Chunmin
    Sha, Qi
    Sun, Wenbing
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2014, 48 (06) : 540 - 547