Patient Satisfaction After Femoral Arterial Access Site Closure Using the ExoSealA® Vascular Closure Device Compared to Manual Compression: A Prospective Intra-individual Comparative Study

被引:12
作者
Pieper, Claus Christian [1 ]
Thomas, Daniel [1 ]
Nadal, Jennifer [2 ]
Willinek, Winfried A. [1 ]
Schild, Hans Heinz [1 ]
Meyer, Carsten [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
[2] Univ Bonn, Inst Med Biometry Informat & Epidemiol, D-53105 Bonn, Germany
关键词
Vascular closure device; ExoSeal (R) vascular closure device; Femoral arterial access; Angiography; Access site management; PERCUTANEOUS CORONARY INTERVENTION; ANGIO-SEAL; CARDIAC-CATHETERIZATION; SINGLE-CENTER; PUNCTURE; HEMOSTASIS; EXPERIENCE; EFFICACY; SAFETY; ECLIPSE;
D O I
10.1007/s00270-015-1204-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To intra-individually compare discomfort levels and patient satisfaction after arterial access closure using the ExoSeal(A (R)) vascular closure device (VCD) and manual compression (MC) in a prospective study design. Patients undergoing two planned interventions from 07/2013 to 09/2014 could participate in the study. Access closure was performed with an ExoSeal(A (R))-VCD in one and MC in the other intervention. Patients were clinically and sonographically examined and were given questionnaires 1 day after intervention [groin- and back-pain during bedrest (100-point visual analog scale; 0: no pain); comfortability of bedrest (10-point Likert scale, 1: comfortable), satisfaction with closure (10-point Likert scale, 1: very satisfied)]. Results were analyzed in a cross-over design. 48 patients (29 male, median age 62.5 (32-88) years) were included. An ExoSeal(A (R))-VCD was used first in 25 cases. As four of these subsequently refused MC as second intervention, data from 44 patients could be analyzed. All closures were technically successful (successful device deployment) without major complications. Groin- and back-pain after VCD-use/MC was 0 (0-15) vs. 10 (0-80) and 0 (0-75) vs. 25 (0-90), respectively (p < 0.0001). Bedrest after VCD-use was more comfortable than after MC [1 (range 1-7) vs. 6 (2-10); p < 0.0001]. Satisfaction with the closure procedure and with the intervention in general was higher after VCD-use compared to MC [1 (1-3) vs. 5 (2-10) and 1 (1-2) vs. 2 (1-4), respectively; p < 0.0001]. Intra-individual comparison showed pain levels and discomfort to be significantly lower after ExoSeal(A (R)) use compared to MC. VCD closure was associated with higher satisfaction both with the closure itself and with the intervention in general.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 27 条
  • [1] Meta-analysis of randomized trials on the efficacy of vascular closure devices after diagnostic angiography and angioplasty
    Biancari, Fausto
    D'Andrea, Vito
    Di Marco, Carlo
    Savino, Grazia
    Tiozzo, Valentina
    Catania, Antonio
    [J]. AMERICAN HEART JOURNAL, 2010, 159 (04) : 518 - 531
  • [2] Efficacy and Time-To-Hemostasis of Antegrade Femoral Access Closure Using the ExoSeal Vascular Closure Device: A Retrospective Single-Center Study
    Boschewitz, J. M.
    Pieper, C. C.
    Andersson, M.
    Nadal, J.
    Schild, H. H.
    Meyer, C.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2014, 48 (05) : 585 - 591
  • [3] Retrospective Evaluation of Safety and Effectiveness of the EXOSEAL Vascular Closure Device for Single Vascular Closure and Closure after Repeat Puncture in Diagnostic and Interventional Radiology: Single-center Experience
    Boschewitz, Jack M.
    Andersson, Magnus
    Naehle, Claas P.
    Schild, Hans H.
    Wilhelm, Kai
    Meyer, Carsten
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (05) : 698 - 702
  • [4] Vascular access and closure in coronary angiography and percutaneous intervention
    Byrne, Robert A.
    Cassese, Salvatore
    Linhardt, Maryam
    Kastrati, Adnan
    [J]. NATURE REVIEWS CARDIOLOGY, 2013, 10 (01) : 27 - 40
  • [5] Vascular closure devices - The second devices
    Dauerman, Harold L.
    Applegate, Robert J.
    Cohen, David J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (17) : 1617 - 1626
  • [6] Closure of the femoral artery after cardiac catheterization: A comparison of Angio-Seal, StarClose, and manual compression
    Deuling, J. H. H.
    Vermeulen, R. P.
    Anthonio, R. A.
    van den Heuvel, A. F. M.
    Jaarsma, T.
    Jessurun, G.
    de Smet, B. J. G. L.
    Tan, E. S.
    Zijistra, F.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (04) : 518 - 523
  • [7] Duffin D C, 2001, J Invasive Cardiol, V13, P354
  • [8] Systematic use of a collagen-based vascular closure device immediately after cardiac catheterization procedures in 1,317 consecutive patients
    Eggebrecht, H
    Haude, M
    Woertgen, U
    Schmermund, A
    von Birgelen, C
    Naber, C
    Baumgart, D
    Kaiser, C
    Oldenburg, O
    Bartel, T
    Kroeger, K
    Erbel, R
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 57 (04) : 486 - 495
  • [9] Safety and Effectiveness of Repeat Arterial Closure Using the AngioSeal Device in Patients with Hepatic Malignancy
    Hieb, Robert A.
    Neisen, Melissa J.
    Hohenwalter, Eric J.
    Molnar, Jim A.
    Rilling, William S.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (12) : 1704 - 1708
  • [10] Percutaneous arterial closure devices
    Hoffer, EK
    Bloch, RD
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (07) : 865 - 885