Comparative evaluation of BacT/ALERT 3D and BACTEC systems for the recovery of pathogens causing bloodstream infections

被引:22
作者
Jamal, Wafaa [1 ]
Tamaray, Gigette [1 ]
Pazhoor, Aleyamma [1 ]
Rotimi, V. O. [1 ]
机构
[1] Mubarak Al Kabeer Hosp, Dept Lab Med, Microbiol Unit, Jabriya, Kuwait
关键词
BacT/ALERT blood culture system; BACTEC 9240 blood culture system; bacteraemia;
D O I
10.1159/000092186
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To compare BacT/ALERT (BTA) and BACTEC 9240 (BAC), two continuously monitoring automated blood culture systems, for the recovery of bloodstream pathogens and standard media available for these systems. Materials and Methods: Blood samples from 100 adults and 50 paediatric patients suspected of having bloodstream infections were inoculated at the bedside into non-vented BTA and BAC standard blood culture bottles and incubated in their respective instruments. The time to growth detection (TD) was recorded for each bottle that became positive. A quantitative assay was also carried out with 5 standard bloodstream pathogens to assess TD of each pathogen as well as the quantity of organisms recovered. Results: A total of 23 isolates representing true infections were recovered by both BTA and BAC bottles, indicating a blood culture positivity rate of 15.3%, 18 (78.3%) by BTA bottles and 13 (56.5%) by BAC. Proteus mirabilis, Pseudomonas aeruginosa and Clostridium perfringens were recovered only by the BTA system. The average TDs were 19.0 and 24.6 h for BTA and BAC, respectively. Analysis of the quantitative growth of known pathogens in both systems was more or less the same for Staphylococcus aureus, Escherichia coli and P. aeruginosa but slightly different for Haemophilus influenzae and Streptococcus pneumoniae. The anaerobic bottle of the BTA did not support the growth of H. influenzae below an inoculum of 10(10) CFU/ml whereas the BAC did so at a lower inoculum of 10(8) CFU/ml. TD for S. pneumoniae in the BTA was about half of that in the BAC. Conclusions: The BTA system appears to be more efficient in detecting common bloodstream pathogens as a higher inoculum is needed for the BAC system to detect the same organism. Copyright (C) 2006 S. Karger AG, Basel.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 12 条
[1]  
DORSHER CW, 1991, REV INFECT DIS, V13, P633
[2]   A one-year prospective study of nosocomial bacteraemia in ICU and non-ICU patients and its impact on patient outcome [J].
Garrouste-Orgeas, M ;
Chevret, S ;
Mainardi, JL ;
Timsit, JF ;
Misset, B ;
Carlet, J .
JOURNAL OF HOSPITAL INFECTION, 2000, 44 (03) :206-213
[3]  
GILL VJ, 2000, MANDELL DOUGLAS BENN, P184
[4]  
Jorgensen J. H., 2003, Manual of clinical microbiology
[5]  
Kellogg JA, 2000, J CLIN MICROBIOL, V38, P2181
[6]   Controlled clinical comparison of BacT/ALERT standard aerobic medium with BACTEC standard aerobic medium for culturing blood [J].
Mirrett, S ;
Reller, LB ;
Petti, CA ;
Woods, CW ;
Vazirani, B ;
Sivadas, R ;
Weinstein, MP .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2391-2394
[7]   Update on detection of bacteremia and fungemia [J].
Reimer, LG ;
Wilson, ML ;
Weinstein, MP .
CLINICAL MICROBIOLOGY REVIEWS, 1997, 10 (03) :444-&
[8]  
VIGANO EF, 1999, MICROBIOLOGIA MED, V14, P280
[9]   Nosocomial primary bloodstream infections in intensive care unit patients in a nonteaching community medical center: A 21-month prospective study [J].
Warren, DK ;
Zack, JE ;
Elward, AM ;
Cox, MJ ;
Fraser, VJ .
CLINICAL INFECTIOUS DISEASES, 2001, 33 (08) :1329-1335
[10]   THE CLINICAL-SIGNIFICANCE OF POSITIVE BLOOD CULTURES - A COMPREHENSIVE ANALYSIS OF 500 EPISODES OF BACTEREMIA AND FUNGEMIA IN ADULTS .1. LABORATORY AND EPIDEMIOLOGIC OBSERVATIONS [J].
WEINSTEIN, MP ;
RELLER, LB ;
MURPHY, JR ;
LICHTENSTEIN, KA .
REVIEWS OF INFECTIOUS DISEASES, 1983, 5 (01) :35-53