Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation

被引:20
|
作者
Bernhardt, Peter [1 ]
Rodewald, Christoph [1 ]
Seeger, Julia [1 ]
Gonska, Birgid [1 ]
Buckert, Dominik [1 ]
Radermacher, Michael [1 ]
Hombach, Vinzenz [1 ]
Rottbauer, Wolfgang [1 ]
Woehrle, Jochen [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Magnetic resonance imaging; Transcatheter aortic valve implantation; ACUTE KIDNEY INJURY; MR-ANGIOGRAPHY; STENOSIS; ECHOCARDIOGRAPHY; ACETYLCYSTEINE; QUANTIFICATION; DISEASE; ANNULUS; RISK;
D O I
10.1007/s00392-015-0920-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard. Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter. Mean age of the study cohort was 82.2 +/- A 4.9 years, log EuroScore was 25.2 +/- A 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 +/- A 6.9 mm. MRI yielded a mean perimeter of 76.5 +/- A 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001). In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [21] DISTAL ABDOMINAL AORTIC THROMBOSIS DIAGNOSED BY THREE-DIMENSIONAL CONTRAST-ENHANCED MAGNETIC RESONANCE ANGIOGRAPHY
    Sharpley, Jenelle
    Thode, Hank
    Sestina, Lisbeth
    Park, Richard
    Monnet, Eric
    Kraft, Susan L.
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (04) : 370 - 375
  • [22] Incidental thoracic findings in computed tomography scans before transcatheter aortic valve implantation
    Markowiak, Till
    Holzamer, Andreas
    Hilker, Michael
    Pregler, Benedikt
    Debl, Kurt
    Hofmann, Hans-Stefan
    Ried, Michael
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2019, 28 (04) : 559 - 565
  • [23] The feasibility of relaxation-enhanced angiography without contrast and triggering for preprocedural planning of transcatheter aortic valve implantation
    Wang, Rui
    Liu, Xinmin
    Yao, Jing
    Schoepf, U. Joseph
    Griffith, Joseph
    Wang, Jiayang
    Lian, Jianxiu
    Jiang, Ke
    Song, Guangyuan
    Xu, Lei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [24] Impact of Valve Over-Sizing After Transcatheter Aortic Valve Implantation With a Self-Expanding Valve: A Multislice Computed Tomography Study
    Drakopoulou, Maria
    Toutouzas, Konstantinos
    Stathogiannis, Konstantinos
    Latsios, George
    Sideris, Skevos
    Xanthopoulou, Maria
    Penesopoulou, Vicky
    Trantalis, George
    Synetos, Andreas
    Papanikolaou, Angelos
    Aggeli, Constantina
    Vavuranakis, Manolis
    Tousoulis, Dimitrios
    JOURNAL OF INVASIVE CARDIOLOGY, 2019, 31 (05) : E76 - E82
  • [25] Contrast-enhanced body magnetic resonance angiography: how we do it
    Aguet, Julien
    Gill, Navjot
    Tassos, Vivian P.
    Chavhan, Govind B.
    Lam, Christopher Z.
    PEDIATRIC RADIOLOGY, 2022, 52 (02) : 262 - 270
  • [26] SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    Achenbach, Stephan
    Delgado, Victoria
    Hausleiter, Joerg
    Schoenhagen, Paul
    Min, James K.
    Leipsic, Jonathon A.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 366 - 380
  • [27] Feasibility of ultra-low contrast 64-slice computed tomography angiography before transcatheter aortic valve implantation: a real-world experience
    Spagnolo, Pietro
    Giglio, Manuela
    Di Marco, Daniela
    Latib, Azeem
    Besana, Francesca
    Chieffo, Alaide
    Montorfano, Matteo
    Sironi, Sandro
    Alfieri, Ottavio
    Colombo, Antonio
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (01) : 24 - 33
  • [28] Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma
    Yoo, Jeongin
    Lee, Jeong Min
    Kang, Hyo-Jin
    Bae, Jae Seok
    Jeon, Sun Kyung
    Yoon, Jeong Hee
    KOREAN JOURNAL OF RADIOLOGY, 2023, 24 (10) : 983 - 995
  • [29] Utility of computed tomography in cases of aortic valve stenosis before and after transcatheter aortic valve implantation
    Takaoka, Hiroyuki
    Kitahara, Hideki
    Ota, Joji
    Suzuki-Eguchi, Noriko
    Sasaki, Haruka
    Mori, Naoto
    Takahashi, Manami
    Iida, Yasunori
    Matsuura, Kaoru
    Nakayama, Takashi
    Matsumiya, Goro
    Kobayashi, Yoshio
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2020, 35 (01) : 72 - 84
  • [30] Image Quality and Stenosis Assessment of Non-Contrast-Enhanced 3-T Magnetic Resonance Angiography in Patients with Peripheral Artery Disease Compared with Contrast-Enhanced Magnetic Resonance Angiography and Digital Subtraction Angiography
    Liu, Jiayi
    Zhang, Nan
    Fang, Zhaoyang
    Luo, Nan
    Zhao, Yike
    Bi, Xiaoming
    An, Jing
    Chen, Zhong
    Liu, Dongting
    Wen, Zhaoying
    Fan, Zhanming
    Li, Debiao
    PLOS ONE, 2016, 11 (11):