Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation

被引:20
|
作者
Bernhardt, Peter [1 ]
Rodewald, Christoph [1 ]
Seeger, Julia [1 ]
Gonska, Birgid [1 ]
Buckert, Dominik [1 ]
Radermacher, Michael [1 ]
Hombach, Vinzenz [1 ]
Rottbauer, Wolfgang [1 ]
Woehrle, Jochen [1 ]
机构
[1] Univ Ulm, Dept Internal Med 2, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Magnetic resonance imaging; Transcatheter aortic valve implantation; ACUTE KIDNEY INJURY; MR-ANGIOGRAPHY; STENOSIS; ECHOCARDIOGRAPHY; ACETYLCYSTEINE; QUANTIFICATION; DISEASE; ANNULUS; RISK;
D O I
10.1007/s00392-015-0920-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Correct sizing of the aortic annulus in aortic valve stenosis is crucial for successful transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) seems to be most promising imaging modality for this pre-interventional diagnostic work-up, but has the disadvantage of exposing mostly co-morbid patients to iodine and nephrotoxic contrast agents. To establish a useful sizing method for TAVI without the use of contrast media, we compared measurements of a non-contrast magnetic resonance imaging (MRI) technique with MSCT serving as the reference standard. Fifty-two patients who underwent TAVI were previously examined with MSCT and MRI, respectively. MRI examination included a 3D steady-state free-precession sequence covering the entire ascending aorta. Perimeter and area of the aortic root were analyzed by two blinded readers in consensus using a dedicated software. Decisions for Sapien 3 valve size of both imaging modalities were compared using the mean derived annulus diameter. Mean age of the study cohort was 82.2 +/- A 4.9 years, log EuroScore was 25.2 +/- A 4.8 %. Mean aortic annulus perimeter as measured by MSCT was 76.7 +/- A 6.9 mm. MRI yielded a mean perimeter of 76.5 +/- A 6.7 mm with a good correlation coefficient (r = 0.93, p < 0.0001). Decision for valve size showed good correlation between both imaging modalities (r = 0.94, p < 0.0001). In conclusion, non-contrast MRI shows good correlation to MSCT in the assessment of the aortic annulus and valve sizing. This non-contrast technique might be a reasonable alternative for aortic root sizing before TAVI without the use of nephrotoxic contrast agents, especially in patients with severely reduced kidney function.
引用
收藏
页码:273 / 278
页数:6
相关论文
共 50 条
  • [1] Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation
    Peter Bernhardt
    Christoph Rodewald
    Julia Seeger
    Birgid Gonska
    Dominik Buckert
    Michael Radermacher
    Vinzenz Hombach
    Wolfgang Rottbauer
    Jochen Wöhrle
    Clinical Research in Cardiology, 2016, 105 : 273 - 278
  • [2] Non-contrast Enhanced Magnetic Resonance Angiography is Superior to Contrast-enhanced Magnetic Resonance Angiography for Correct Aortic Sizing Before Transcatheter Aortic Valve Replacement: A Comparison to Multislice Computed Tomography
    Rodewald, Christoph
    Spiess, Jochen
    Brunner, Horst
    Walcher, Thomas
    Kummel, Andreas
    Rottbauer, Wolfgang
    Bernhardt, Peter
    CIRCULATION, 2012, 126 (21)
  • [3] Pre-Procedural Assessment of the Femoral Access Route for Transcatheter Aortic Valve Implantation: Comparison of a Non-Contrast Time-of-Flight Magnetic Resonance Angiography Protocol with Contrast-Enhanced Dual-Source Computed Tomography Angiography
    Brado, Johannes
    Breitbart, Philipp
    Hein, Manuel
    Pache, Gregor
    Schmitt, Ramona
    Hein, Jonas
    Apweiler, Matthias
    Soschynski, Martin
    Schlett, Christopher
    Bamberg, Fabian
    Neumann, Franz-Josef
    Westermann, Dirk
    Krauss, Tobias
    Ruile, Philipp
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [4] Quantification of aortic valve calcification on contrast-enhanced CT of patients prior to transcatheter aortic valve implantation
    Eberhard, Matthias
    Mastalerz, Monika
    Frauenfelder, Thomas
    Tanner, Felix C.
    Maisano, Francesco
    Nietlispach, Fabian
    Seifert, Burkhardt
    Alkadhi, Hatem
    Thi Dan Linh Nguyen-Kim
    EUROINTERVENTION, 2017, 13 (08) : 921 - 927
  • [5] Quantification of Aortic Valve Calcification in Contrast-Enhanced Computed Tomography
    Laohachewin, Danai
    Ruile, Philipp
    Breitbart, Philipp
    Minners, Jan
    Jander, Nikolaus
    Soschynski, Martin
    Schlett, Christopher L.
    Neumann, Franz-Josef
    Westermann, Dirk
    Hein, Manuel
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [6] Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation
    de Morais, Gustavo Pires
    Bettencourt, Nuno
    Silva, Guida
    Ferreira, Nuno
    Sousa, Olga
    Caeiro, Daniel
    Rocha, Joao
    Carvalho, Monica
    Leite, Daniel
    Braga, Pedro
    Fonseca, Conceicao
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2011, 30 (09) : 717 - 726
  • [7] Non-Contrast-Enhanced and Contrast-Enhanced Magnetic Resonance Angiography in Living Donor Liver Vascular Anatomy
    Liao, Chien-Chang
    Chen, Meng-Hsiang
    Yu, Chun-Yen
    Tsang, Leung-Chit Leo
    Chen, Chao-Long
    Hsu, Hsien-Wen
    Lim, Wei-Xiong
    Chuang, Yi-Hsuan
    Huang, Po-Hsun
    Cheng, Yu-Fan
    Ou, Hsin-You
    DIAGNOSTICS, 2022, 12 (02)
  • [8] Contrast-enhanced computed tomography assessment of aortic stenosis
    Cartlidge, Timothy R. G.
    Bing, Rong
    Kwiecinski, Jacek
    Guzzetti, Ezequiel
    Pawade, Tania A.
    Doris, Mhairi K.
    Adamson, Philip D.
    Massera, Daniele
    Lembo, Maria
    Peeters, Frederique E. C. M.
    Couture, Christian
    Berman, Daniel S.
    Dey, Damini
    Slomka, Piotr
    Pibarot, Philippe
    Newby, David E.
    Clavel, Marie-Annick
    Dweck, Marc R.
    HEART, 2021, 107 (23) : 1905 - 1911
  • [9] Early Aortic Transcatheter Heart Valve Thrombosis Diagnostic Value of Contrast-Enhanced Multidetector Computed Tomography
    Leetmaa, Tina
    Hansson, Nicolaj C.
    Leipsic, Jonathon
    Jensen, Kaare
    Poulsen, Steen H.
    Andersen, Henning R.
    Jensen, Jesper M.
    Webb, John
    Blanke, Philipp
    Tang, Mariann
    Norgaard, Bjarne L.
    Circulation-Cardiovascular Interventions, 2015, 8 (04)
  • [10] Contrast-Enhanced Magnetic Resonance Angiography
    Chandra, Tushar
    Pukenas, Bryan
    Mohan, Suyash
    Melhem, Elias
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (04) : 687 - +