A sustainable localised air distribution system for enhancing thermal environment and indoor air quality of poultry house for semiarid region

被引:17
|
作者
Al Assaad, Douaa K. [1 ]
Orabi, Mohamad S. [1 ]
Ghaddar, Nesreen K. [1 ]
Ghali, Kamel F. [1 ]
Salam, Darine A. [2 ]
Ouahrani, Djamel [3 ]
Farran, Mohamad T. [4 ]
Habib, Rima R. [5 ]
机构
[1] Amer Univ Beirut, Dept Mech Engn, Beirut 11072020, Lebanon
[2] Amer Univ Beirut, Dept Civil & Environm Engn, Beirut 11072020, Lebanon
[3] Qatar Univ, Coll Engn, Dept Architecture & Urban Planning, POB 2713, Doha, Qatar
[4] Amer Univ Beirut, Dept Agr, Beirut 11072020, Lebanon
[5] Amer Univ Beirut, Dept Environm Hlth, Beirut 11072020, Lebanon
关键词
Direct evaporative cooling; dew point evaporative cooling; poultry house ventilation; localised air distribution; energy savings; DISPLACEMENT VENTILATION; COOLING SYSTEM; PERFORMANCE; EMISSIONS; COMFORT; HEAT; FLOW; EXCHANGERS; EVALUATE; AMMONIA;
D O I
10.1016/j.biosystemseng.2021.01.002
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
This work compares the performance of three passive cooling systems in meeting thermal and indoor air quality requirements in a poultry house located in semi-arid climate. The first two systems are a direct evaporative cooler and a cross-flow dew point evaporative cooler supplying air through a conventional tunnel ventilation that achieves uniform thermal and indoor air quality conditions. The third system is a dew-point evaporative cooler combined with a localised ventilation system to further reduce air and water con-sumption. To achieve these objectives, a modular analysis was adopted where mathe-matical models were developed for the evaporative coolers and the tunnel-ventilated poultry house module. Moreover, a computational fluid dynamics model was developed and experimentally validated for the compartment conditioned by the localised system. The evaporative coolers were sized and the hourly variation in the required fresh air and water supply was determined for the cooling season. Results of the economic analysis showed that the cost of the dew-point evaporative cooler was 6.8% lower than that of the direct evaporative cooling, with better compliance to poultry house thermal and air quality requirements. Using localised ventilation instead of conventional with the dew point apparatus further reduced costs by 4.7%, while achieving similar conditions of temperature and air quality. (c) 2021 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:70 / 92
页数:23
相关论文
共 50 条
  • [1] A Sustainable Approach for Improving Air Quality in a Poultry House
    Orabi, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    Salam, Darine
    Farran, Mohamad
    Habib, Rima
    Srour, Issam
    International Conference on Efficient Building Design: Material and HVAC Equipment Technologies, 2020, 2020-November : 205 - 214
  • [2] Evaluation of the influence of one air circulation system on LGS house indoor thermal environment
    Li, Jing
    Deng, Zhi-qiang
    Li, Chuan
    Zhou, Di
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4343 - 4348
  • [3] Thermal comfort prediction of an underfloor air distribution system in a large indoor environment
    Kim, Gon
    Schaefer, Laura
    Lim, Tae Sub
    Kim, Jeong Tai
    ENERGY AND BUILDINGS, 2013, 64 : 323 - 331
  • [4] Critical review of standards for indoor thermal environment and air quality
    Khovalyg, Dolaana
    Kazanci, Ongun B.
    Halvorsen, Hanne
    Gundlach, Ida
    Bahnfleth, William P.
    Toftum, Jorn
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2020, 213
  • [5] Impact of windcatcher on the thermal comfort and indoor air quality in a modern house
    Mamari, Manal Al
    Khan, Hayder Murad
    Al Saadi, Saleh
    Al Hashim, Alya
    BUILDING RESEARCH AND INFORMATION, 2025, 53 (1-2): : 204 - 219
  • [6] A Study on Actual Conditions of Thermal Environment and Indoor Air Quality in a Japanese Traditional House Corresponding to Sericulture
    Wang, Yan
    Yoshino, Yasuko
    Kumagai, Kazukiyo
    Takahashi, Miyuki
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2010, 9 (02) : 509 - 514
  • [7] Actual conditions and the mechanism of thermal environment and indoor air quality in a traditional house corresponding to sericultural buildings
    Wang, Yan
    Yoshino, Yasuko
    Kumagai, Kazukiyo
    Takahashi, Miyuki
    Sekiguchi, Katsuaki
    Journal of Environmental Engineering, 2008, 73 (634) : 1451 - 1455
  • [8] Optimization of fresh air conditioning system for indoor thermal comfort and air quality
    Yang, P. (yang_peizhi@csu.edu.cn), 1600, Sila Science, University Mah Mekan Sok, No 24, Trabzon, Turkey (31):
  • [9] Evaluation and control on indoor environment of cold air distribution system
    Yang, F
    ENERGY & ENVIRONMENT - A WORLD OF CHALLENGES AND OPPORTUNITIES, PROCEEDINGS, 2003, : 339 - 343
  • [10] Indoor thermal environment and energy performance in a central air heating system using a heat pump for a house with underfloor space for heat distribution
    Kindaichi, Sayaka
    Kindaichi, Tomonori
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2022, 43 (06): : 755 - 766