Determination of low ppm levels of dimethyl sulfate in an aqueous soluble API intermediate using liquid-liquid extraction and GC-MS

被引:24
|
作者
Zheng, Jie [1 ]
Pritts, Wayne A. [1 ]
Zhang, Shuhong [1 ]
Wittenberger, Steve [2 ]
机构
[1] Abbott Labs, GPRD, Dept R45T, N Chicago, IL 60064 USA
[2] Abbott Labs, GPRD, Dept R450, N Chicago, IL 60064 USA
关键词
Dimethyl sulfate; Genotoxic impurity; API intermediate; GC/MS; Trace analysis; ACTIVE PHARMACEUTICAL INGREDIENTS; CHROMATOGRAPHY-MASS-SPECTROMETRY; HEADSPACE-GAS-CHROMATOGRAPHY; ALKYLATING-AGENTS; GENOTOXIC IMPURITIES; DRUG SUBSTANCES; DIETHYL SULFATE; AIR; INDUCTION; PRODUCTS;
D O I
10.1016/j.jpba.2009.06.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dimethyl sulfate (DMS) is an alkylating reagent commonly used in organic syntheses and pharmaceutical manufacturing processes. Due to its potential carcinogenicity, the level of DMS in the API process needs to be carefully monitored. However, in-process testing for DMS is challenging because of its reactivity and polarity as well as complex matrix effects. In this short communication, we report a GC-MS method for determination of DMS in an API intermediate that is a methyl sulfate salt. To overcome the complex matrix interference, DMS and an internal standard, d(6)-DMS, were extracted from the matrix with methyl tert-butyl ether. GC separation was conducted on a DB-624 column (30 m long, 0.32 mm ID, 1.8 mu m film thickness). MS detection was performed on a single-quad Agilent MSD equipped with an electron impact source while the MSD signal was acquired in selected ion monitoring mode. This GC/MS method showed a linear response for DMS equivalent from 1.0 to 60 ppm. The practical quantitation limit for DMS was 1.0 ppm and the practical detection limit was 0.3 ppm. The relative standard derivation for analyte response was found as 0.1% for six injections of a working standard equivalent to 18.6 ppm of DMS. The spike recovery was ranged from 102.1 to 108.5% for a sample of API intermediate spiked with 8.0 ppm of DMS. In summary, the GC/MS method showed adequate specificity. linearity, sensitivity, repeatability and accuracy for determination of DMS in the API intermediate. This method has been successfully applied to study the efficiency of removing DMS from the process. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1054 / 1059
页数:6
相关论文
共 50 条
  • [31] Vortex-assisted extraction in tandem with dispersive liquid-liquid microextraction followed by GC-MS for determination of Achillea wilhelmsii essential oil
    Sereshti, Hassan
    Ghiasi, Abdollah
    Naderloo, Mandi
    Taghizadeh, Massoud
    Astaneh, Shakiba Darvish Alipoar
    ANALYTICAL METHODS, 2014, 6 (17) : 6695 - 6701
  • [32] Comparison of flavor and aroma volatiles in various beers by liquid-liquid extraction, GC-FID, and GC-MS analyses.
    Wei, A
    Mitchell, AE
    Shibamoto, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U40 - U40
  • [33] Determination of chlorophenol derivatives using the homogeneous liquid-liquid extraction in ternary component system-GC/MS method
    Takagai, Y
    Maekoya, C
    Igarashi, S
    NIPPON KAGAKU KAISHI, 2000, (04) : 291 - 293
  • [34] Determination of doravirine in human plasma using liquid-liquid extraction and HPLC-MS/MS
    Desai, Rajesh
    Roadcap, Brad
    Goykhman, Dina
    Woolf, Eric
    BIOANALYSIS, 2019, 11 (16) : 1495 - 1508
  • [35] Determination of Residual Dimethyl Sulfate in Cephalosporin Using HS-SPME/GC-MS
    Lu, Rongchun
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2024, 62 (10) : 922 - 928
  • [36] Vortex-Assisted Liquid-Liquid Micro-extraction Followed by Head Space Solid Phase Micro-extraction for the Determination of Eugenol in Fish Using GC-MS
    Xu Liang
    Ting-Ting Feng
    Jian-Hai Wu
    Ming Du
    Lei Qin
    Zhen-Yu Wang
    Xian-Bing Xu
    Food Analytical Methods, 2018, 11 : 790 - 796
  • [37] Vortex-Assisted Liquid-Liquid Micro-extraction Followed by Head Space Solid Phase Micro-extraction for the Determination of Eugenol in Fish Using GC-MS
    Liang, Xu
    Feng, Ting-Ting
    Wu, Jian-Hai
    Du, Ming
    Qin, Lei
    Wang, Zhen-Yu
    Xu, Xian-Bing
    FOOD ANALYTICAL METHODS, 2018, 11 (03) : 790 - 796
  • [38] Determination of multiclass pesticides in food commodities by pressurized liquid extraction using GC-MS/MS and LC-MS/MS
    Frenich, AG
    Salvador, IM
    Martínez Vidal, J
    López-López, T
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (7-8) : 1106 - 1118
  • [39] Optimization of an LC-MS method for the determination of artesunate and dihydroartemisinin plasma levels using liquid-liquid extraction
    Van Quekelberghe, Stijn A. A.
    Soomro, Shahid A.
    Cordonnier, Jan A.
    Jansen, R. Herwig
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2008, 32 (02) : 133 - 139
  • [40] Determination of organophosphate pesticides in sea and surface water with ultrasound-assisted dispersive liquid-liquid micro-extraction coupled to GC-MS/MS analysis
    Habedank, Friederike
    Abraham, Marion
    Tardel, Helmar
    Feldhusen, Frerk
    Schulz-Bull, Detlef E.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2017, 97 (09) : 819 - 830