Determination of low ppm levels of dimethyl sulfate in an aqueous soluble API intermediate using liquid-liquid extraction and GC-MS

被引:24
|
作者
Zheng, Jie [1 ]
Pritts, Wayne A. [1 ]
Zhang, Shuhong [1 ]
Wittenberger, Steve [2 ]
机构
[1] Abbott Labs, GPRD, Dept R45T, N Chicago, IL 60064 USA
[2] Abbott Labs, GPRD, Dept R450, N Chicago, IL 60064 USA
关键词
Dimethyl sulfate; Genotoxic impurity; API intermediate; GC/MS; Trace analysis; ACTIVE PHARMACEUTICAL INGREDIENTS; CHROMATOGRAPHY-MASS-SPECTROMETRY; HEADSPACE-GAS-CHROMATOGRAPHY; ALKYLATING-AGENTS; GENOTOXIC IMPURITIES; DRUG SUBSTANCES; DIETHYL SULFATE; AIR; INDUCTION; PRODUCTS;
D O I
10.1016/j.jpba.2009.06.022
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Dimethyl sulfate (DMS) is an alkylating reagent commonly used in organic syntheses and pharmaceutical manufacturing processes. Due to its potential carcinogenicity, the level of DMS in the API process needs to be carefully monitored. However, in-process testing for DMS is challenging because of its reactivity and polarity as well as complex matrix effects. In this short communication, we report a GC-MS method for determination of DMS in an API intermediate that is a methyl sulfate salt. To overcome the complex matrix interference, DMS and an internal standard, d(6)-DMS, were extracted from the matrix with methyl tert-butyl ether. GC separation was conducted on a DB-624 column (30 m long, 0.32 mm ID, 1.8 mu m film thickness). MS detection was performed on a single-quad Agilent MSD equipped with an electron impact source while the MSD signal was acquired in selected ion monitoring mode. This GC/MS method showed a linear response for DMS equivalent from 1.0 to 60 ppm. The practical quantitation limit for DMS was 1.0 ppm and the practical detection limit was 0.3 ppm. The relative standard derivation for analyte response was found as 0.1% for six injections of a working standard equivalent to 18.6 ppm of DMS. The spike recovery was ranged from 102.1 to 108.5% for a sample of API intermediate spiked with 8.0 ppm of DMS. In summary, the GC/MS method showed adequate specificity. linearity, sensitivity, repeatability and accuracy for determination of DMS in the API intermediate. This method has been successfully applied to study the efficiency of removing DMS from the process. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1054 / 1059
页数:6
相关论文
共 50 条
  • [1] Determination of Low-ppm Levels of 1,4-Butane Sultone in Sulfobutyl Ether β-Cyclodextrin Using Liquid-Liquid Extraction and GC-MS
    Wang, Meng
    Wen, Hongmei
    Yu, Sheng
    Yan, Zhengyu
    CHROMATOGRAPHIA, 2012, 75 (15-16) : 937 - 941
  • [2] Liquid-liquid extraction and GC-MS analysis for acidic drugs
    Yuen, PK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U112 - U112
  • [3] Determination of endosulfan and some pyrethroids in waters by micro liquid-liquid extraction and GC-MS
    A. Fernández-Gutiérrez
    J. L. Martínez-Vidal
    F. J. Arrebola-Liébanas
    A. Gonzalez-Casado
    J. L. Vílchez
    Fresenius' Journal of Analytical Chemistry, 1998, 360 : 568 - 572
  • [4] Determination of endosulfan and some pyrethroids in waters by micro liquid-liquid extraction and GC-MS
    Fernandez-Gutierrez, A
    Martinez-Vidal, JL
    Arrebola-Liebanas, FJ
    Gonzalez-Casado, A
    Vilchez, JK
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1998, 360 (05): : 568 - 572
  • [5] A Novel Liquid-Liquid Extraction for the Determination of Sertraline in Tap Water and Waste Water at Trace Levels by GC-MS
    Kocoglu, Elif Seda
    Bakirdere, Sezgin
    Keyf, Seyfullah
    BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2017, 99 (03) : 354 - 359
  • [6] A Novel Liquid-Liquid Extraction for the Determination of Nicotine in Tap Water, Wastewater, and Saliva at Trace Levels by GC-MS
    Dobrowska, Joanna Sonia
    Erarpat, Sezin
    Chormey, Dotse Selali
    Pyrzynska, Krystyna
    Bakirdere, Sezgin
    JOURNAL OF AOAC INTERNATIONAL, 2016, 99 (03) : 806 - 812
  • [7] A novel liquid-liquid extraction for the determination of naphthalene by GC-MS with deuterated anthracene as internal standard
    Erarpat, Sezin
    Ozzeybek, Gozde
    Chormey, Dotse Selali
    Erulas, Fatih
    Turak, Fatma
    Bakirdere, Sezgin
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2017, 189 (10)
  • [8] A novel liquid-liquid extraction for the determination of naphthalene by GC-MS with deuterated anthracene as internal standard
    Sezin Erarpat
    Gözde Özzeybek
    Dotse Selali Chormey
    Fatih Erulaş
    Fatma Turak
    Sezgin Bakırdere
    Environmental Monitoring and Assessment, 2017, 189
  • [9] Simultaneous Determination of Aldrin and Mirex in Honey by Liquid-Liquid Extraction with Low-Temperature Purification combined with GC-MS
    Santos, Silas de Souza
    Pereira de Freitas, Lucas Victor
    Sicupira, Lazaro Chaves
    Silverio, Flaviano Oliveira
    FOOD ANALYTICAL METHODS, 2022, 15 (10) : 2744 - 2755
  • [10] Determination of Tramadol by Dispersive Liquid-Liquid Microextraction Combined with GC-MS
    Habibollahi, Saeed
    Tavakkoli, Nahid
    Nasirian, Vahid
    Khani, Hossein
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (05) : 655 - 661