LVRT Control based on Partial State-Feedback Linearization for SCIG Wind Turbine Systems

被引:0
作者
Anh Tan Nguyen [1 ]
Lee, Dong-Choon [1 ]
机构
[1] Yeungnam Univ, Dept Elect Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
来源
2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE) | 2020年
关键词
DC-link voltage control; feedback linearization; LVRT; SCIG; wind turbine system; CONVERTER;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, a novel low-voltage ride-through (LVRT) control scheme for the squirrel-cage induction generator (SCIG) wind turbine systems is proposed, based on the feedback linearization. At first, the nonlinear relationship between the DC-link voltage V-dc and the q-axis stator voltage of SCIG is derived. Through the application of the feedback linearization theory, a DC-link voltage controller with the output of q-axis stator voltage of SCIG is designed. Consequently, V-dc can be controlled by the generator-side converter instead of the line-side converter. The effectiveness of the proposed method has been verified by the simulation and experimental results under various grid conditions.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 17 条
  • [1] Supercapacitor energy storage for wind energy applications
    Abbey, Chad
    Joos, Geza
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2007, 43 (03) : 769 - 776
  • [2] Robust Control for High Performance Induction Motor Drives Based on Partial State-Feedback Linearization
    Accetta, Angelo
    Alonge, Francesco
    Cirrincione, Maurizio
    D'Ippolito, Filippo
    Pucci, Marcello
    Rabbeni, Roberto
    Sferlazza, Antonino
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2019, 55 (01) : 490 - 503
  • [3] Feedback Linearizing Control of Induction Motor Considering Magnetic Saturation Effects
    Accetta, Angelo
    Alonge, Francesco
    Cirrincione, Maurizio
    Pucci, Marcello
    Sferlazza, Antonino
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (06) : 4843 - 4854
  • [4] Sensorless vector control of SCIG-based small wind turbine systems using cascaded second-order generalized integrators
    Anh Tan Nguyen
    Lee, Dong-Choon
    [J]. JOURNAL OF POWER ELECTRONICS, 2020, 20 (03) : 764 - 773
  • [5] Low-voltage ride-through of a full converter wind turbine with permanent magnet generator
    Conroy, J. F.
    Watson, R.
    [J]. IET RENEWABLE POWER GENERATION, 2007, 1 (03) : 182 - 189
  • [6] Multi-pole permanent magnet synchronous generator wind turbines' grid support capability in uninterrupted operation during grid faults
    Hansen, A. D.
    Michalke, G.
    [J]. IET RENEWABLE POWER GENERATION, 2009, 3 (03) : 333 - 348
  • [7] A Fault Ride-Through Technique of DFIG Wind Turbine Systems Using Dynamic Voltage Restorers
    Ibrahim, Ahmad Osman
    Thanh Hai Nguyen
    Lee, Dong-Choon
    Kim, Su-Chang
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (03) : 871 - 882
  • [8] LVRT Scheme of PMSG Wind Power Systems Based on Feedback Linearization
    Kim, Ki-Hong
    Jeung, Yoon-Cheul
    Lee, Dong-Choon
    Kim, Heung-Geun
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (05) : 2376 - 2384
  • [9] Li WH, 2006, SER ADV BIOINFORM, V3, P1
  • [10] A Stationary Reference Frame Grid Synchronization System for Three-Phase Grid-Connected Power Converters Under Adverse Grid Conditions
    Rodriguez, Pedro
    Luna, Alvaro
    Santiago Munoz-Aguilar, Raul
    Etxeberria-Otadui, Ion
    Teodorescu, Remus
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (01) : 99 - 112