Numerical investigation on the capacity and efficiency of a deep enhanced U-tube borehole heat exchanger system for building heating

被引:53
作者
Chen, Chaofan [1 ,2 ]
Cai, Wanlong [1 ,3 ]
Naumov, Dmitri [1 ,4 ]
Tu, Kun [5 ,6 ]
Zhou, Hongwei [6 ]
Zhang, Yuping [3 ,7 ]
Kolditz, Olaf [1 ,2 ]
Shao, Haibing [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[2] Tech Univ Dresden, Appl Environm Syst Anal, D-01069 Dresden, Germany
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[4] Freiberg Univ Min & Technol, D-09599 Freiberg, Germany
[5] Univ Calif Riverside, Dept Environm Sci, Riverside, CA 92521 USA
[6] China Univ Min & Technol Beijing, Beijing 100083, Peoples R China
[7] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Geothermal energy; Building heating; Enhanced U-tube borehole heat exchanger; Long-term thermal performance; Efficiency; THERMAL PERFORMANCE; BEND PIPE; SUSTAINABILITY; EXTRACTION; EQUATIONS; MODEL; FLUID; FIELD; FLOW; MASS;
D O I
10.1016/j.renene.2021.01.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Deep geothermal energy has become widely exploited in recent years through the use of closed loop systems for building heating. Intended to meet high heating demand in densely populated neighbourhoods, an enhanced U-tube borehole heat exchanger (EUBHE) system, in which a deviated deep borehole is connected with another vertical one to form a closed loop, is introduced in this work. For capacity and efficiency analysis of applying EUBHE systems to extract deep geothermal energy, a 3D numerical model is implemented and established based on the OpenGeoSys software. Through evaluation by thermal performance tests and thermal response tests on the EUBHE system, the maximum sustainable heat extraction rate is found to be 1.2 MW in a single heating season and 1.1 MW in 10 years, which can provide heating to more than 35,000 m(2) of residential buildings located in northern China. Moreover, the 10-year system thermal performance and efficiency are evaluated when coupled with a ground source heat pump (GSHP), and compared with the two deep borehole heat exchanger (2-DBHE) array system that has the same total borehole length as the EUBHE system. Results show that GSHP-coupled EUBHE system is more efficient than the 2-DBHE array system, as it consumes 27% less electricity. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:557 / 572
页数:16
相关论文
共 50 条
  • [41] Influencing factors analysis for the long-term thermal performance of medium and deep U-type borehole heat exchanger system
    Huang, Shuai
    Li, Jiqin
    Zhu, Ke
    Dong, Jiankai
    Jiang, Yiqiang
    JOURNAL OF BUILDING ENGINEERING, 2023, 68
  • [42] Field test and numerical investigation on deep coaxial borehole heat exchanger based on distributed optical fiber temperature sensor
    Huang, Yibin
    Zhang, Yanjun
    Xie, Yangyang
    Zhang, Yu
    Gao, Xuefeng
    Ma, Jingchen
    ENERGY, 2020, 210
  • [43] Numerical investigation on the reservoir heat production capacity of a downhole heat exchanger geothermal system
    Shi, Yu
    Song, Xianzhi
    Li, Gensheng
    Yang, Ruiyue
    Shen, Zhonghou
    Lyu, Zehao
    GEOTHERMICS, 2018, 72 : 163 - 169
  • [44] Numerical investigation of serpentine earth-to-air heat exchanger for passive building heating systems by recovery criteria
    Soroush, Hamed
    Entezari, Soroush
    Lakzian, Esmail
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 53
  • [45] Effects of building load characteristics on heating performance of the medium-deep U-type borehole heat exchanger coupled heat pumps: A coupled dynamic simulation
    Huang, Shuai
    Lin, Duotong
    Dong, Jiankai
    Li, Ji
    APPLIED ENERGY, 2025, 377
  • [46] Numerical Analysis of the Heat Transfer Characteristics of Vertical U-Tube Ground Heat Exchanger Used in Ground Coupled Heat Pump
    Yang, Weibo
    Shi, Mingheng
    Chen, Zhenqian
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 1857 - 1864
  • [47] Numerical investigation of efficiency and economic analysis of an evacuated U-tube solar collector with different nanofluids
    Kaya, Hueseyin
    Arslan, Kamil
    HEAT AND MASS TRANSFER, 2019, 55 (03) : 581 - 593
  • [48] Thermal behavior and performance of shallow-deep-mixed borehole heat exchanger array for sustainable building cooling and heating
    Cheng, Nan
    Zhou, Chaohui
    Luo, Yongqiang
    Shen, Junhao
    Tian, Zhiyong
    Sun, Deyu
    Fan, Jianhua
    Zhang, Ling
    Deng, Jie
    Rosen, Marc A.
    ENERGY AND BUILDINGS, 2023, 291
  • [49] A COMPARATIVE STUDY OF THE LONG-TERM PERFORMANCE OF VERTICAL U-TUBE BOREHOLE HEAT EXCHANGER AND FOUNDATION PILES IN A COLD CLIMATE
    Adebayo, Philip
    Jathunge, Charaka Beragama
    Shor, Roman
    Mohamad, Abdulmajeed
    Mwesigye, Aggrey
    PROCEEDINGS OF ASME 2023 INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, IMECE2023, VOL 7, 2023,
  • [50] Comprehensive simulation based thermal performance comparison between single and double U-tube borehole heat exchanger and sensitivity analysis
    Kerme, Esa Dube
    Fung, Alan S.
    ENERGY AND BUILDINGS, 2021, 241