Numerical investigation on the capacity and efficiency of a deep enhanced U-tube borehole heat exchanger system for building heating

被引:53
作者
Chen, Chaofan [1 ,2 ]
Cai, Wanlong [1 ,3 ]
Naumov, Dmitri [1 ,4 ]
Tu, Kun [5 ,6 ]
Zhou, Hongwei [6 ]
Zhang, Yuping [3 ,7 ]
Kolditz, Olaf [1 ,2 ]
Shao, Haibing [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[2] Tech Univ Dresden, Appl Environm Syst Anal, D-01069 Dresden, Germany
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[4] Freiberg Univ Min & Technol, D-09599 Freiberg, Germany
[5] Univ Calif Riverside, Dept Environm Sci, Riverside, CA 92521 USA
[6] China Univ Min & Technol Beijing, Beijing 100083, Peoples R China
[7] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Geothermal energy; Building heating; Enhanced U-tube borehole heat exchanger; Long-term thermal performance; Efficiency; THERMAL PERFORMANCE; BEND PIPE; SUSTAINABILITY; EXTRACTION; EQUATIONS; MODEL; FLUID; FIELD; FLOW; MASS;
D O I
10.1016/j.renene.2021.01.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Deep geothermal energy has become widely exploited in recent years through the use of closed loop systems for building heating. Intended to meet high heating demand in densely populated neighbourhoods, an enhanced U-tube borehole heat exchanger (EUBHE) system, in which a deviated deep borehole is connected with another vertical one to form a closed loop, is introduced in this work. For capacity and efficiency analysis of applying EUBHE systems to extract deep geothermal energy, a 3D numerical model is implemented and established based on the OpenGeoSys software. Through evaluation by thermal performance tests and thermal response tests on the EUBHE system, the maximum sustainable heat extraction rate is found to be 1.2 MW in a single heating season and 1.1 MW in 10 years, which can provide heating to more than 35,000 m(2) of residential buildings located in northern China. Moreover, the 10-year system thermal performance and efficiency are evaluated when coupled with a ground source heat pump (GSHP), and compared with the two deep borehole heat exchanger (2-DBHE) array system that has the same total borehole length as the EUBHE system. Results show that GSHP-coupled EUBHE system is more efficient than the 2-DBHE array system, as it consumes 27% less electricity. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:557 / 572
页数:16
相关论文
共 50 条
  • [31] Thermo-Hydraulic Performance of U-Tube Borehole Heat Exchanger with Different Cross-Sections
    Zhou, Aizhao
    Huang, Xianwen
    Wang, Wei
    Jiang, Pengming
    Li, Xinwei
    SUSTAINABILITY, 2021, 13 (06)
  • [32] Short-term fluid temperature variations in either a coaxial or U-tube borehole heat exchanger
    Gordon, David
    Bolisetti, Tirupati
    Ting, David S. -K.
    Reitsma, Stanley
    GEOTHERMICS, 2017, 67 : 29 - 39
  • [33] Long-term Performance Evaluation and Economic Analysis for Deep Borehole Heat Exchanger Heating System in Weihe Basin
    Cai, Wanlong
    Wang, Fenghao
    Jiang, Jinghua
    Wang, Zeyuan
    Liu, Jun
    Chen, Chaofan
    FRONTIERS IN EARTH SCIENCE, 2022, 10
  • [34] Study on the Coupled Heat Transfer Model Based on Groundwater Advection and Axial Heat Conduction for the Double U-Tube Vertical Borehole Heat Exchanger
    Zhang, Linlin
    Shi, Zhonghua
    Yuan, Tianhao
    SUSTAINABILITY, 2020, 12 (18)
  • [35] Energy analysis and performance assessment of a hybrid deep borehole heat exchanger heating system with direct heating and coupled heat pump approaches
    Wang, Zeyuan
    Wang, Fenghao
    Liu, Jun
    Li, Yizhen
    Wang, Ming
    Luo, Yongqiang
    Ma, Longxia
    Zhu, Chao
    Cai, Wanlong
    ENERGY CONVERSION AND MANAGEMENT, 2023, 276
  • [36] Optimization of geothermal interaction of a double U-tube borehole heat exchanger for space heating and cooling applications using Taguchi method and utility concept
    Kumar, Satish
    Murugesan, K.
    GEOTHERMICS, 2020, 83
  • [37] Numerical simulation of a Deep Borehole Heat Exchanger in the Krafla geothermal system
    Renaud, Theo
    Verdin, Patrick
    Falcone, Gioia
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 143
  • [38] Heat transfer mechanism and parameter analysis of the U-tube borehole ground heat exchanger of middle-shallow geothermal energy
    Zhang, Wenke
    Gao, Yuxue
    Yao, Haiqing
    Li, Wenjing
    Cui, Ping
    Yu, Mingzhi
    Zhou, Shiyu
    JOURNAL OF BUILDING ENGINEERING, 2025, 102
  • [39] Numerical investigation on the long-term thermal response of a U-type medium-deep borehole heat exchanger under specific heat extraction rates
    Zhang, Qunlin
    Li, Bowen
    Liu, Fei
    Shui, Linqi
    Han, Yuanhong
    Zhao, Tong
    JOURNAL OF BUILDING ENGINEERING, 2025, 100
  • [40] Analysis on the transient heat transfer process inside and outside the borehole for a vertical U-tube ground heat exchanger under short-term heat storage
    Dai, L. H.
    Shang, Y.
    Li, X. L.
    Li, S. F.
    RENEWABLE ENERGY, 2016, 87 : 1121 - 1129