Numerical investigation on the capacity and efficiency of a deep enhanced U-tube borehole heat exchanger system for building heating

被引:63
作者
Chen, Chaofan [1 ,2 ]
Cai, Wanlong [1 ,3 ]
Naumov, Dmitri [1 ,4 ]
Tu, Kun [5 ,6 ]
Zhou, Hongwei [6 ]
Zhang, Yuping [3 ,7 ]
Kolditz, Olaf [1 ,2 ]
Shao, Haibing [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Permoserstr 15, D-04318 Leipzig, Germany
[2] Tech Univ Dresden, Appl Environm Syst Anal, D-01069 Dresden, Germany
[3] Xi An Jiao Tong Univ, Sch Human Settlements & Civil Engn, Xian 710049, Shaanxi, Peoples R China
[4] Freiberg Univ Min & Technol, D-09599 Freiberg, Germany
[5] Univ Calif Riverside, Dept Environm Sci, Riverside, CA 92521 USA
[6] China Univ Min & Technol Beijing, Beijing 100083, Peoples R China
[7] Minist Nat Resources, Key Lab Coal Resources Explorat & Comprehens Util, Xian 710021, Shaanxi, Peoples R China
关键词
Geothermal energy; Building heating; Enhanced U-tube borehole heat exchanger; Long-term thermal performance; Efficiency; THERMAL PERFORMANCE; BEND PIPE; SUSTAINABILITY; EXTRACTION; EQUATIONS; MODEL; FLUID; FIELD; FLOW; MASS;
D O I
10.1016/j.renene.2021.01.033
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Deep geothermal energy has become widely exploited in recent years through the use of closed loop systems for building heating. Intended to meet high heating demand in densely populated neighbourhoods, an enhanced U-tube borehole heat exchanger (EUBHE) system, in which a deviated deep borehole is connected with another vertical one to form a closed loop, is introduced in this work. For capacity and efficiency analysis of applying EUBHE systems to extract deep geothermal energy, a 3D numerical model is implemented and established based on the OpenGeoSys software. Through evaluation by thermal performance tests and thermal response tests on the EUBHE system, the maximum sustainable heat extraction rate is found to be 1.2 MW in a single heating season and 1.1 MW in 10 years, which can provide heating to more than 35,000 m(2) of residential buildings located in northern China. Moreover, the 10-year system thermal performance and efficiency are evaluated when coupled with a ground source heat pump (GSHP), and compared with the two deep borehole heat exchanger (2-DBHE) array system that has the same total borehole length as the EUBHE system. Results show that GSHP-coupled EUBHE system is more efficient than the 2-DBHE array system, as it consumes 27% less electricity. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:557 / 572
页数:16
相关论文
共 52 条
[1]   Efficient numerical modeling of borehole heat exchangers [J].
Al-Khoury, R. ;
Koelbel, T. ;
Schramedei, R. .
COMPUTERS & GEOSCIENCES, 2010, 36 (10) :1301-1315
[2]   Transient heat transfer in a coaxial borehole heat exchanger [J].
Beier, Richard A. ;
Acuna, Jose ;
Mogensen, Paine ;
Palm, Bjorn .
GEOTHERMICS, 2014, 51 :470-482
[3]   Transient heat transfer in a U-tube borehole heat exchanger [J].
Beier, Richard A. .
APPLIED THERMAL ENGINEERING, 2014, 62 (01) :256-266
[4]   Experimental and numerical investigation of heat transfer performance and sustainability of deep borehole heat exchangers coupled with ground source heat pump systems [J].
Cai, Wanlong ;
Wang, Fenghao ;
Liu, Jun ;
Wang, Zhihua ;
Ma, Zhenjun .
APPLIED THERMAL ENGINEERING, 2019, 149 :975-986
[5]   Efficiency of closed loop geothermal heat pumps: A sensitivity analysis [J].
Casasso, Alessandro ;
Sethi, Rajandrea .
RENEWABLE ENERGY, 2014, 62 :737-746
[6]  
Chen C, WELLBORE HEAT TRANSP
[7]   Numerical investigation on the performance, sustainability, and efficiency of the deep borehole heat exchanger system for building heating [J].
Chen, Chaofan ;
Shao, Haibing ;
Naumov, Dmitri ;
Kong, Yanlong ;
Tu, Kun ;
Kolditz, Olaf .
GEOTHERMAL ENERGY, 2019, 7 (01)
[8]   Shifted thermal extraction rates in large Borehole Heat Exchanger array - A numerical experiment [J].
Chen, Shuang ;
Witte, Francesco ;
Kolditz, Olaf ;
Shao, Haibing .
APPLIED THERMAL ENGINEERING, 2020, 167
[9]   Critical comparison between thermal performance test (TPT) and thermal response test (TRT): Differences in heat transfer process and extractable information [J].
Choi, Wonjun ;
Kikumoto, Hideki ;
Ooka, Ryozo .
ENERGY CONVERSION AND MANAGEMENT, 2019, 199
[10]   COMPREHENSIVE CORRELATING EQUATIONS FOR HEAT, MASS AND MOMENTUM-TRANSFER IN FULLY DEVELOPED FLOW IN SMOOTH TUBES [J].
CHURCHILL, SW .