Imaging of Soft Tissues Adjacent to Orthopedic Hardware: Comparison of 3-T and 1.5-T MRI

被引:28
作者
Farrelly, Cormac [1 ]
Davarpanah, Amir [2 ]
Brennan, Stephen [3 ]
Sampson, Mathew [4 ]
Eustace, Stephen J. [1 ]
机构
[1] Cappagh Natl Orthopaed Hosp, Dept Radiol, Dublin 11, Ireland
[2] Northwestern Univ Hosp, Dept Radiol, Feinberg Sch Med, Chicago, IL USA
[3] Cappagh Natl Orthopaed Hosp, Dept Orthoped Surg, Dublin 11, Ireland
[4] Sports Surg Clin, Dept Radiol, Dublin, Ireland
关键词
1.5; T; 3; artifact reduction; MRI; susceptibility; TOTAL HIP-ARTHROPLASTY; MUSCULOSKELETAL MRI; METALLIC IMPLANTS; SPIN-ECHO; ARTIFACTS; REPLACEMENT; EXPERIENCE; REDUCTION; IMAGES; 3.0T;
D O I
10.2214/AJR.08.1740
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare metal artifact reduction techniques at 1.5-T and 3-T MRI. MATERIALS AND METHODS. A titanium plate with steel screws was placed in a freshly harvested pig leg. The leg was imaged with 1.5-T and 3-T MRI. A T2-weighted turbo spin-echo sequence was used with echo-train lengths of 8, 16, 32, and 64 and a constant readout bandwidth of 31.2 kHz. The images were compared qualitatively, and the optimal echotrain length was selected. Images were acquired at the optimal echo-train length with four different readout bandwidths. Artifact was measured quantitatively, and image quality was ranked qualitatively. The qualitatively best image acquired at 1.5 T was compared with the qualitatively highest-ranked image acquired at 3 T. RESULTS. At both 1.5 T and 3 T, optimal images of equal quality were produced at echotrain lengths of 8 and 16. At higher readout bandwidths, there was quantitatively less artifact. The qualitatively best images were acquired at a readout bandwidth of 31.2 kHz at 1.5 T and 62.5 kHz at 3 T (Cronbach's alpha = 1.00). The optimal image at 3 T was qualitatively superior to that at 1.5 T. CONCLUSION. Optimizing image acquisition parameters in this phantom model resulted in similar quantitative susceptibility artifact at 3 T and 1.5 T and better qualitative images at 3 T than at 1.5 T.
引用
收藏
页码:W60 / W64
页数:5
相关论文
共 23 条
  • [1] Projecting the need for hip replacement over the next three decades: influence of changing demography and threshold for surgery
    Birrell, F
    Johnell, O
    Silman, A
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1999, 58 (09) : 569 - 572
  • [2] Muskuloskeletal MR imaging at 3.0 T: current status and future perspectives
    Bolog, Nicolae
    Nanz, Daniel
    Weishaupt, Dominik
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (06) : 1298 - 1307
  • [3] Optimizing imaging techniques in the postoperative patient
    Buckwalter, Kenneth A.
    [J]. SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2007, 11 (03) : 261 - 272
  • [4] MR imaging of soft tissues adjacent to orthopaedic hardware: Techniques to minimize susceptibility artefact
    Eustace, S
    Goldberg, R
    Williamson, D
    Melhem, ER
    Oladipo, O
    Yucel, EK
    Jara, H
    [J]. CLINICAL RADIOLOGY, 1997, 52 (08) : 589 - 594
  • [5] A comparison of conventional spin-echo and turbo spin-echo imaging of soft tissues adjacent to orthopedic hardware
    Eustace, S
    Jara, H
    Goldberg, R
    Fenlon, H
    Mason, M
    Melhem, ER
    Yucel, EK
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 455 - 458
  • [6] Imaging orthopedic hardware with an emphasis on hip prostheses
    Eustace, S
    Shah, B
    Mason, M
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (01) : 67 - +
  • [7] Musculoskeletal MRI at 3.0T: Initial clinical experience
    Gold, GE
    Suh, B
    Sawyer-Glover, A
    Beaulieu, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (05) : 1479 - 1486
  • [8] Musculoskeletal MRI at 3.0T: Relaxation times and image contrast
    Gold, GE
    Han, E
    Stainsby, J
    Wright, G
    Brittain, J
    Beaulieu, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 183 (02) : 343 - 351
  • [9] MRI as a problem-solving tool in unexplained failed total hip replacement following conventional assessment
    Johnston, Ciaran
    Kerr, Jennifer
    Ford, Stephanie
    O'Byrne, John
    Eustace, Stephen
    [J]. SKELETAL RADIOLOGY, 2007, 36 (10) : 955 - 961
  • [10] KING KF, 2004, HDB MRI PULSE SEQUEN, P367