A Meta-Analysis of Design- and Manufacturing-Related Parameters Influencing the Wear Behavior of Metal-on-Metal Hip Joint Replacements

被引:16
|
作者
Kretzer, Jan Philippe [2 ]
Kleinhans, Jennifer A. [3 ]
Jakubowitz, Eike [2 ]
Thomsen, Marc [4 ]
Heisel, Christian [1 ]
机构
[1] ARCUS Sportklin, D-75179 Pforzheim, Germany
[2] Heidelberg Univ, Biomech Lab, Dept Orthopaed, Heidelberg, Germany
[3] Univ Connecticut, Biomed Engn Program, Sch Engn, Storrs, CT USA
[4] German Red Cross Hosp, Baden, Switzerland
关键词
metal-on-metal; wear; heat treatment; simulator; hip; QUANTITATIVE-ANALYSIS; COBALT-CHROMIUM; RUNNING-IN; SIMULATOR; DEBRIS; LUBRICATION; PERFORMANCE; DIAMETER; SURFACES; VITRO;
D O I
10.1002/jor.20921
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This article aims to clarify the influence of design- and manufacturing-related parameters on wear of metal-on-metal (MoM) joint bearings. A database search for publications on wear simulator studies of MoM bearings was performed. The results of published studies were normalized; groups with individual parameters were defined and analyzed statistically. Fifty-six investigations studying a total of 200 implants were included in the analysis. Clearance, head size, carbon content, and manufacturing method were analyzed as parameters influencing MoM wear. This meta-analysis revealed a strong influence of clearance on running-in wear for implants of 36-mm diameter and an increase in steady-state wear of heat treated components. (C) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:1473-1480, 2009
引用
收藏
页码:1473 / 1480
页数:8
相关论文
共 19 条
  • [1] Analysis of Run-in-Stage Wear Behavior and Contact Mechanics of Metal-on-Metal Hip Joint Bearings with Different Radial Clearances
    Chen, Yan
    Li, Yunping
    Kurosu, Shingo
    Meng, Qingen
    Tang, Ning
    Koizumi, Yuichiro
    Chiba, Akihiko
    MATERIALS TRANSACTIONS, 2015, 56 (06) : 826 - 834
  • [2] Analysis of mixed lubrication mechanism in metal-on-metal hip joint replacements
    Jin, ZM
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2002, 216 (H1) : 85 - 89
  • [3] Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested In a physiological hip joint simulator
    Firkins, PJ
    Tipper, JL
    Saadatzadeh, MR
    Ingham, E
    Stone, MH
    Farrar, R
    Fisher, J
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2001, 11 (02) : 143 - 157
  • [4] A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    Goldsmith, AAJ
    Dowson, D
    Isaac, GH
    Lancaster, JG
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) : 39 - 47
  • [5] Determination of Low Wear Rates in Metal-On-Metal Hip Joint Replacements Based on Ultra Trace Element Analysis in Simulator Studies
    Kretzer, J. P.
    Krachler, M.
    Reinders, J.
    Jakubowitz, E.
    Thomsen, M.
    Heisel, C.
    TRIBOLOGY LETTERS, 2010, 37 (01) : 23 - 29
  • [6] Retrieval Analysis of Large-Head Modular Metal-on-Metal Hip Replacements of a Single Design
    Gascoyne, Trevor C.
    Turgeon, Thomas R.
    Burnell, Colin D.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (06) : 1945 - 1952
  • [7] Influence of Lubrication Performance on Wear Factor in Metal-on-Metal Hip Joint Replacement using Numerical Analysis
    Harun, Muhamad Noor
    Jin, Zhongmin
    Syahrom, Ardiyansyah
    INTERNATIONAL TRIBOLOGY CONFERENCE MALAYSIA 2013, 2013, 68 : 95 - 101
  • [8] Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales
    Smith, Alison J.
    Dieppe, Paul
    Vernon, Kelly
    Porter, Martyn
    Blom, Ashley W.
    LANCET, 2012, 379 (9822) : 1199 - 1204
  • [9] Metal-on-metal or metal-on-polyethylene for total hip arthroplasty: a meta-analysis of prospective randomized studies
    Qu, Xinhua
    Huang, Xiaolu
    Dai, Kerong
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (11) : 1573 - 1583
  • [10] Compare the revision rate of metal-on-metal and metal-on-polyethylene for total hip replacement: a meta-analysis
    Zhang, Liang
    Bao, Dongmei
    Chen, Zhirong
    Li, Peng
    Guo, Haohui
    Song, Kening
    Gao, Zhihui
    Zhang, Shuai
    Jin, Qunhua
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (01): : 59 - 68